• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CLC/TS 60034-25:2008

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Rotating electrical machines - Part 25: Guidance for the design and performance of a.c. motors specifically designed for converter supply
Withdrawn date

02-02-2024

Published date

12-12-2008

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 System characteristics
   4.1 General
   4.2 System information
   4.3 Torque/speed considerations
   4.4 Motor requirements
5 Losses and their effects (for induction motors fed from
   U-converters)
   5.1 General
   5.2 Location of the additional losses due to converter
        supply and ways to reduce them
   5.3 Converter features to reduce the motor losses
   5.4 Use of filters to reduce additional motor losses
        due to converter supply
   5.5 Temperature and life expectancy
   5.6 Determination of motor efficiency
6 Noise, vibration and torsional oscillation
   6.1 Noise
   6.2 Vibration (excluding torsional oscillation)
   6.3 Torsional oscillation
7 Motor insulation electrical stresses
   7.1 General
   7.2 Causes
   7.3 Winding electrical stress
   7.4 Insulation stress limitation
   7.5 Responsibilities
   7.6 Converter characteristics
   7.7 Methods of reduction of voltage stress
   7.8 Motor choice
8 Bearing currents
   8.1 Sources of bearing currents in converter-fed
        motors
   8.2 Generation of high-frequency bearing currents
   8.3 Common mode circuit
   8.4 Stray capacitances
   8.5 Consequences of excessive bearing currents
   8.6 Preventing high-frequency bearing current damage
   8.7 Additional considerations for motors fed by high
        voltage U-converters
   8.8 Bearing current protection for motors fed by
        high-voltage current-source converters (I-converters)
9 Installation
   9.1 Earthing, bonding and cabling
   9.2 Reactors and filters
   9.3 Integral motors (integrated motor and drive modules)
10 Additional considerations for permanent magnet (PM)
   synchronous motors fed by U-converters
   10.1 System characteristics
   10.2 Losses and their effects
   10.3 Noise, vibration and torsional oscillation
   10.4 Motor insulation electrical stresses
   10.5 Bearing currents
   10.6 Particular aspects of permanent magnets
11 Additional considerations for cage induction motors
   fed by high voltage U-converters
   11.1 General
   11.2 System characteristics
   11.3 Losses and their effects
   11.4 Noise, vibration and torsional oscillation
   11.5 Motor insulation electrical stresses
   11.6 Bearing currents
12 Additional considerations for synchronous motors
   fed U-converters
   12.1 System characteristics
   12.2 Losses and their effects
   12.3 Noise, vibration and torsional oscillation
   12.4 Motor insulation electrical stresses
   12.5 Bearing currents
13 Additional considerations for cage induction motors
   fed by block-type I-converters
   13.1 System characteristics
   13.2 Losses and their effects
   13.3 Noise, vibration and torsional oscillation
   13.4 Motor insulation electrical stresses
   13.5 Bearing currents
   13.6 Additional considerations for six-phase cage
        induction motors
14 Additional considerations for synchronous motors
   fed by LCI
   14.1 System characteristics
   14.2 Losses and their effects
   14.3 Noise, vibration and torsional oscillation
   14.4 Motor insulation electrical stresses
   14.5 Bearing currents
15 Additional considerations for pulsed I-converters (PWM CSI)
   feeding induction motors
   15.1 System characteristics
   15.2 Losses and their effects
   15.3 Noise, vibration and torsional oscillation
   15.4 Motor insulation electrical stresses
   15.5 Bearing currents
16 Other motor/converter systems
   16.1 Drives supplied by cyclo-converters
   16.2 Wound rotor induction (asynchronous) machines
        supplied by I-converters in the rotor circuit
   16.3 Wound rotor induction (asynchronous) machines
        supplied by U-converters in the rotor circuit
Annex A (normative) - Converter characteristics
Annex B (informative) - Converter output spectra
Annex C (informative) - Noise increments due to converter
                        supply
Bibliography
Annex ZA (normative) - Normative references to international
                       publications with their corresponding
                       European publications

Describes the design features and performance characteristics of polyphase cage induction motors specifically designed for use on voltage source converter supplies up to 1 000 V. Also specifies the interface parameters and interactions between the motor and the converter including installation guidance as part of a power drive system.

Committee
CLC/TC 2
DocumentType
Technical Specification
PublisherName
European Committee for Standards - Electrical
Status
Withdrawn

I.S. EN 60034-30-1:2014 ROTATING ELECTRICAL MACHINES - PART 30-1: EFFICIENCY CLASSES OF LINE OPERATED AC MOTORS (IE CODE)
I.S. EN 60079-15:2010 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
VDE 0160-109-2 : 2018-01 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 9-2: ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS AND THEIR DRIVEN APPLICATIONS - ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS (IEC 61800-9-2:2017)
EN 60034-18-41:2014 Rotating electrical machines - Part 18-41: Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters - Qualification and quality control tests
EN 60034-30-1:2014 Rotating electrical machines - Part 30-1: Efficiency classes of line operated AC motors (IE code)
CEI EN 60034-28 : 2014 ROTATING ELECTRICAL MACHINES - PART 28: TEST METHODS FOR DETERMINING QUANTITIES OF EQUIVALENT CIRCUIT DIAGRAMS FOR THREE-PHASE LOW-VOLTAGE CAGE INDUCTION MOTORS
CEI EN 60079-15 : 2012 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
EN 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
BS EN 60034-28:2013 Rotating electrical machines Test methods for determining quantities of equivalent circuit diagrams for three-phase low-voltage cage induction motors
09/30214359 DC : 0 BS EN 50533 - RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
I.S. EN 60034-18-41:2014 ROTATING ELECTRICAL MACHINES - PART 18-41: PARTIAL DISCHARGE FREE ELECTRICAL INSULATION SYSTEMS (TYPE 1) USED IN ROTATING ELECTRICAL MACHINES FED FROM VOLTAGE CONVERTERS - QUALIFICATION AND QUALITY CONTROL TESTS
BS EN 60034-30-1:2014 Rotating electrical machines Efficiency classes of line operated AC motors (IE code)
BS EN 60079-15:2010 Explosive atmospheres Equipment protection by type of protection \'n\'
UNE-EN 60079-14:2016 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
DIN EN 61800-9-2 : 2018-01 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 9-2: ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS AND THEIR DRIVEN APPLICATIONS - ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS (IEC 61800-9-2:2017)
BS EN 60034-30:2009 Rotating electrical machines Efficiency classes of single-speed, three-phase, cage-induction motors (IE-code)
CEI EN 60034-30-1 : 2015 ROTATING ELECTRICAL MACHINES - PART 30-1: EFFICIENCY CLASSES OF LINE OPERATED AC MOTORS (IE CODE)
CEI EN 60034-18-41 : 2014 ROTATING ELECTRICAL MACHINES - PART 18-41: PARTIAL DISCHARGE FREE ELECTRICAL INSULATION SYSTEMS (TYPE I) USED IN ROTATING ELECTRICAL MACHINES FED FROM VOLTAGE CONVERTERS - QUALIFICATION AND QUALITY CONTROL TESTS
CEI CLC/TS 50534 : 2011 RAILWAY APPLICATIONS - GENERIC SYSTEM ARCHITECTURES FOR ONBOARD ELECTRIC AUXILIARY POWER SYSTEMS
BS EN 60079-0 : 2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
I.S. EN 60034-28:2013 ROTATING ELECTRICAL MACHINES - PART 28: TEST METHODS FOR DETERMINING QUANTITIES OF EQUIVALENT CIRCUIT DIAGRAMS FOR THREE-PHASE LOW-VOLTAGE CAGE INDUCTION MOTORS (IEC 60034-28:2012 (EQV))
UNE-EN 50533:2012 Railway applications - Three-phase train line voltage characteristics.
UNE-EN 60079-15:2013 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
BS EN 50598-2 : 2014 ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS & THEIR DRIVEN APPLICATIONS - PART 2: ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS
BS EN 60034-18-41:2014 Rotating electrical machines Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters. Qualification and quality control tests
PREN 50533 : DRAFT 2009 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
UNE-EN 60034-28:2013 Rotating electrical machines - Part 28: Test methods for determining quantities of equivalent circuit diagrams for three-phase low-voltage cage induction motors
UNE-EN 50598-2:2015 Ecodesign for power drive systems, motor starters, power electronics & their driven applications - Part 2: Energy efficiency indicators for power drive systems and motor starters
I.S. EN 50598-2:2014 ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS & THEIR DRIVEN APPLICATIONS - PART 2: ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS
EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
EN 60034-28:2013 Rotating electrical machines - Part 28: Test methods for determining quantities of equivalent circuit diagrams for three-phase low-voltage cage induction motors
EN 50598-2:2014/A1:2016 ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS & THEIR DRIVEN APPLICATIONS - PART 2: ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS

IEC 61800-3:2017 Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods
IEC 61800-2:2015 Adjustable speed electrical power drive systems - Part 2: General requirements - Rating specifications for low voltage adjustable speed a.c. power drive systems
IEC 61800-4:2002 Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV
EN 61800-5-2:2017 Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional
IEC 60034-9:2003+AMD1:2007 CSV Rotating electrical machines - Part 9: Noise limits
IEC 60050-195:1998 International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock
EN 60034-1:2010/corrigendum Oct. 2010 ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE
IEC TR 61000-5-2:1997 Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 2: Earthing and cabling
EN 60034-14:2004/A1:2007 ROTATING ELECTRICAL MACHINES - PART 14: MECHANICAL VIBRATION OF CERTAIN MACHINES WITH SHAFT HEIGHTS 56 MM AND HIGHER - MEASUREMENT, EVALUATION AND LIMITS OF VIBRATION SEVERITY
IEC TS 60034-18-41:2006 Rotating electrical machines - Part 18-41: Qualification and type tests for Type I electrical insulation systems used in rotating electrical machines fed from voltage converters
EN 60034-9:2005/A1:2007 ROTATING ELECTRICAL MACHINES - PART 9: NOISE LIMITS
EN 61800-5-1:2007/A1:2017 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-1: SAFETY REQUIREMENTS - ELECTRICAL, THERMAL AND ENERGY (IEC 61800-5-1:2007/A1:2016)
EN 61800-2:2015 Adjustable speed electrical power drive systems - Part 2: General requirements - Rating specifications for low voltage adjustable speed a.c. power drive systems
IEC TS 60034-17:2006 Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
IEC 60034-14:2003+AMD1:2007 CSV Rotating electrical machines - Part 14: Mechanical vibration of certain machines with shaft heights 56 mm and higher - Measurement, evaluation and limits of vibration severity
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
IEC 60034-2:1972 Rotating electrical machines. Part 2: Methods for determining losses and efficiency of rotating electrical machinery from tests (excluding machines for traction vehicles)
EN 61800-3 : 2004 AMD 1 2012 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004/A1:2011)
EN 60034-2:1996/A2:1996 ROTATING ELECTRICAL MACHINES - PART 2: METHODS FOR DETERMINING LOSSES AND EFFICIENCY OF ROTATING ELECTRICAL MACHINERY FROM TESTS (EXCLUDING MACHINES FOR TRACTION VEHICLES)
IEC TR 61800-6:2003 Adjustable speed electrical power drive systems - Part 6: Guide for determination of types of load duty and corresponding current ratings
EN 60034-6:1993 Rotating electrical machines - Part 6: Methods of cooling (IC Code)
IEC 61800-5-2:2016 Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional
IEC TR 61000-5-1:1996 Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 1: General considerations - Basic EMC publication

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.