CSA A440.2-A440.3 : 2014( R 2018)

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

FENESTRATION ENERGY PERFORMANCE/USER GUIDE TO CSA A440.2-14, FENESTRATION ENERGY PERFORMANCE
Available format(s)

Hardcopy , PDF

Withdrawn date

25-03-2019

Language(s)

English, French

Published date

01-10-2018

Preface
A440.2-14, Fenestration energy performance
1 Scope
2 Reference publications
3 Definitions and symbols
4 Selection of specimens
5 Overall coefficient of heat transfer (U-factor)
6 Solar-optical properties
7 Air leakage rate
8 Energy Rating of residential fenestration systems
9 Reporting of results
10 Markings
11 Evaluation of fenestration system condensation
   resistance (optional)
Annexes
A (informative) - Condensation resistance test
A440.3-14, User guide to CSA A440.2-14, Fenestration
           energy performance
I.1 Purpose of CSA A440.2
I.2 Overall coefficient of heat transfer (U-factor)
I.3 Solar heat gain coefficient (SHGC)
I.4 Visible transmittance (VT)
I.5 Air leakage
I.6 Residential Energy Ratings (ER) for fenestration
      systems
I.7 Improving fenestration system energy performance
II.1 Scope
II.3 Definitions and symbols
II.8 Energy Rating of residential fenestration systems
II.11 Evaluation of fenestration system condensation
      resistance (optional)
III.1 Considerations for special conditions
III.2 Specific U-factor, solar heat gain coefficient, and
      visible transmittance
III.3 Specific Energy Ratings (ERS)
III.4 Cooling Energy Rating (ERC)

Contains: (a) A440.2-14 - Fenestration energy performance; and (b) A440.3-14 - User guide to CSA A440.2-14, Fenestration energy performance.

1.1 This Standard applies to (a) fenestration systems covered by AAMA/WDMA/CSA 101/I.S.2/A440, including (i) vertically sliding windows (ii) horizontally sliding windows iii) dual-action windows (iv) casement windows, both fixed and operable (v) projecting(awning/hopper) windows (vi) fixed windows (vii) sidelites (viii) transom windows (ix) sliding glass doors (x) side-hinged doors (xi) dual-action side-hinged doors (xii) architectural terrace doors (xiii) unit skylights and roof windows (xiv) greenhouse or garden windows (xv) tubular daylighting devices (b) curtain walls.

DevelopmentNote
French Edition issued on 01-10-2014. (11/2014)
DocumentType
Revision
Pages
98
ProductNote
THIS STANDARD ALSO REFERS TO : AAMA/WDMA/CSA 101/I.S.2/A440-11
PublisherName
Canadian Standards Association
Status
Withdrawn
SupersededBy
Supersedes

CSA F280 : 2012 : INC : ERR ATA : 2016 DETERMINING THE REQUIRED CAPACITY OF RESIDENTIAL SPACE HEATING AND COOLING APPLIANCES
Z5000-18 Building commissioning for energy using systems
09/30196724 DC : 0 BS ISO 18292 - ENERGY PERFORMANCE OF FENESTRATION SYSTEMS - CALCULATION PROCEDURE
CSA F280 : 2012 : INC : UPD 1 : 2014 DETERMINING THE REQUIRED CAPACITY OF RESIDENTIAL SPACE HEATING AND COOLING APPLIANCES
ISO 18292:2011 Energy performance of fenestration systems for residential buildings Calculation procedure
CSA Z320 : 2011 : R2016 BUILDING COMMISSIONING
CSA Z320 : 2011 : INC : UPD 1 : 2011 BUILDING COMMISSIONING
CSA Z320 : 2011 BUILDING COMMISSIONING
ASHRAE HDBK REFRIGERATION : 2014 ASHRAE HANDBOOK - REFRIGERATION
F280-12 (R2017) Determining the required capacity of residential space heating and cooling appliances
CSA A440.4 : 2007 : R2016 WINDOW, DOOR, AND SKYLIGHT INSTALLATION
CSA A440.4 : 2007 WINDOW, DOOR, AND SKYLIGHT INSTALLATION
CSA Z8001 : 2013 COMMISSIONING OF HEALTH CARE FACILITIES
CSA F280 : 2012 DETERMINING THE REQUIRED CAPACITY OF RESIDENTIAL SPACE HEATING AND COOLING APPLIANCES
BS ISO 18292:2011 Energy performance of fenestration systems for residential buildings. Calculation procedure

View more information
£203.70
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.