CAN/CSA-C2.1-06 (R2017)

Current
Current

The latest, up-to-date edition.

Single-Phase and Three-Phase Liquid-Filled Distribution Transformers
Available format(s)

Hardcopy , PDF

Language(s)

English, French

Published date

01-01-2006

Preface
1 Scope
2 Reference publications and definitions
3 Quality assurance
4 Electrical characteristics
5 Electrical connection and designation
6 Bushings and terminals
7 Off-circuit tap changer and voltage selector switches
8 Mechanical characteristics
9 Tests
10 Markings
11 Accessories
12 Optional items
Annexes
A (normative) - Interchangeability of high-voltage bushings
                on pole-mounted distribution transformers
B (normative) - Distribution transformer warning labels

This Standard specifies the requirements for distribution transformers with the exception of those distribution transformers that are covered by CSA C2.2, C227.3, and C227.4.

Preface This is the first edition of CSA C2.1, Single-phase and three-phase liquid-filled distribution transformers.? It supersedes previous editions of CAN/CSA-C2, Single-Phase and Three-phase Liquid-filled Distribution Transformers, Types ONAN and LNAN, published in 1991, 1982, 1976, 1969, 1959, 1944, 1928, and 1920.? It is written in SI (metric) units.? Scope 1.1 This Standard specifies the requirements for distribution transformers with the exception of those distribution transformers that are covered by CSA C2.2, C227.3, and C227.4. Note: The operation of transformers complying with this Standard by other than an electric utility may be subject to additional requirements by the electrical inspection authority having jurisdiction.? 1.2 This Standard applies to single- and three-phase, 60 Hz, liquid-filled distribution transformers, insulation class 34.5 kV or less, rated at 1000 kV.A or below for single phase and at 3000 kV.A or below for three phase.? 1.3 This Standard includes voltage ratings, kV.A ratings, certain mechanical characteristics, and test procedures. Also included are the following performance characteristics: energy efficiency (in accordance with CAN/CSA-C802.1), temperature rise, loading capabilities, sound level, and radio influence voltage (RIV). 1.4 This Standard also applies to self-protected transformers, with the exception of the protective equipment.? 1.5 Except as specified by other CSA Standards, this Standard does not apply to auto-, testing, dry-type, welding, furnace, rectifier, network, subway-type, or special-purpose transformers, or to step-voltage regulators.? 1.6 In CSA Standards, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; \"may\" is used to express an option or that which is permissible within the limits of the standard; and \"can\" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

DevelopmentNote
Supersedes CSA C2. (05/2008)
DocumentType
Standard
ISBN
1-55436-178-8
Pages
72
ProductNote
Reconfirmed EN
PublisherName
Canadian Standards Association
Status
Current
Supersedes

W59-13 Welded steel construction (metal arc welding)
CSA C802.1 : 2013 MINIMUM EFFICIENCY VALUES FOR LIQUID-FILLED DISTRIBUTION TRANSFORMERS
ASTM D 1816 : 2012 : REDLINE Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using VDE Electrodes
CAN/CSA-C50-14 (R2018) Mineral insulating oil, electrical, for transformers and switches
IEEE C57.12.35-2013 IEEE Standard Bar Coding for Distribution Transformers and Step-Voltage Regulators
IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
CSA C22.2 No. 0.15 : 2015 ADHESIVE LABELS
IEEE C57.12.20-2011 REDLINE IEEE Standard for Overhead-Type Distribution Transformers 500 kVA and Smaller: High Voltage, 34 500 V and Below; Low Voltage, 7970/13 800Y V and Below
CSA ISO 9001 : 2016 QUALITY MANAGEMENT SYSTEMS - REQUIREMENTS
IEEE C57.12.28-2014 IEEE Standard for Pad-Mounted Equipment--Enclosure Integrity

View more information
£125.22
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.