• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CSA C61000-3-14 : 2015

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-14: ASSESSMENT OF EMISSION LIMITS FOR HARMONICS, INTERHARMONICS, VOLTAGE FLUCTUATIONS AND UNBALANCE FOR THE CONNECTION OF DISTURBING INSTALLATIONS TO LV POWER SYSTEMS
Available format(s)

Hardcopy , PDF

Superseded date

25-06-2019

Language(s)

English

Published date

01-01-2015

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Basic EMC concepts
5 General principles
6 General guidelines for the assessment of emission levels
7 General summation law
8 Harmonic emission limits for distorting installations in LV
   systems
9 Voltage fluctuation emission limits for installations in LV
   systems
10 Unbalance emission limits for unbalanced installations in
   LV systems
11 Summary diagrams of the evaluation procedure
Annex A (informative) - Example of application of the general
        method for the derivation of limits for a specific type
        of LV networks
Annex B (informative) - Example of application of the general
        method for the calculation of emission limits for a
        specific installation
Annex C (informative) - Harmonic emission limits at stage 2
Annex D (informative) - Calculation of the reduction factors
        for harmonics and unbalance
Annex E (informative) - Example of method to allocate
        harmonic emission limits at stage 3
Annex F (informative) - Example of application of the
        approach presented in Annex E
Annex G (informative) - List of principal letter symbols,
        subscripts and symbols
Bibliography

Specifies guidance on principles that can be used as the basis for determining the requirements for the connection of disturbing installations to low voltage (LV) public power systems.

DocumentType
Standard
Pages
121
PublisherName
Canadian Standards Association
Status
Superseded
SupersededBy

IEC TR 61000-2-6:1995 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 6: Assessment of the emission levels in the power supply of industrial plants as regards low-frequency conducted disturbances
IEC TR 60725:2012 Consideration of reference impedances and public supply network impedances for use in determining the disturbance characteristics of electrical equipment having a rated current ≤75 A per phase
CAN/CSA-C61000-2-2-04 (R2018) Electromagnetic Compatibility (EMC) - Part 2-2: Environment - Compatibility Levels for Low-Frequency Conducted Disturbances and Signalling in Public Low-Voltage Power Supply Systems (Adopted CEI/IEC 61000-2-2:2002, second edition, 2002-03, with Canadian deviations) | Compatibilité électromagnétique (CEM) - Partie 2-2: Environnement - Niveaux de compatibilité pour les perturbations conduites à basse fréquence et la transmission des signaux sur les réseaux publics d\'alimentation basse tension (norme CEI/IEC 61000-2-2:2002 adoptée, deuxième édition, 2002-03, avec exigences propres au Canada)
IEC TR 61000-3-13:2008 Electromagnetic compatibility (EMC) - Part 3-13: Limits - Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems
IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 60050-101:1998 International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics
CSA C61000.3.3 : 2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
IEC TR 61000-3-7:2008 Electromagnetic compatibility (EMC) - Part 3-7: Limits - Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems
IEC TR 61000-2-1:1990 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems
IEC 61000-4-7:2002+AMD1:2008 CSV Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
IEC TR 61000-3-6:2008 Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)

View more information
£250.45
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.