• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DD ENV 1187:2002

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Test methods for external fire exposure to roofs
Available format(s)

Hardcopy , PDF

Superseded date

31-01-2012

Language(s)

English

Published date

31-05-2006

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test 1: Method with burning brands
  4.1 Test equipment
  4.2 Calibration
  4.3 Test conditions (roof pitch)
  4.4 Test specimen
  4.5 Conditioning
  4.6 Test environment
  4.7 Test procedure
  4.8 Observations and measurement
  4.9 Test report
  4.10 Direct field of application of test results
5 Test 2: Method with burning brands and wind
  5.1 Test equipment
  5.2 Calibration
  5.3 Test conditions
  5.4 Test specimen
  5.5 Conditioning
  5.6 Test environment
  5.7 Test procedure
  5.8 Observations and measurements
  5.9 Test report
  5.10 Direct field of application of test results
6 Test 3: Method with burning brands, wind and
          supplementary radiant heat
  6.1 Test equipment
  6.2 Calibration
  6.3 Test conditions
  6.4 Test specimen
  6.5 Conditioning
  6.6 Test environment
  6.7 Test procedure
  6.8 Observations and measurements
  6.9 Test report
  6.10 Direct field of application of test results
7 Test 4 - Two stage test method incorporating burning
           brands, wind and supplementary radiant heat
  7.1 Test equipment
  7.2 Calibration
  7.3 Test conditions
  7.4 Test specimen
  7.5 Conditioning
  7.6 Test environment
  7.7 Test procedure
  7.8 Observations and measurements
  7.9 Test report
  7.10 Direct field of application of test results
Bibliography

Specifies four methods for determining the performance of roofs to external fire exposure.

Committee
FSH/22
DocumentType
Standard
Pages
54
PublisherName
British Standards Institution
RevisionOf
Status
Superseded
SupersededBy

Standards Relationship
ENV 1187:2002/A1:2005 Identical

07/30147204 DC : 0 BS 476-10 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS
BS DD9999(2005) : 2005 CODE OF PRACTICE FOR FIRE SAFETY IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS
BS 6229:2003 Flat roofs with continuously supported coverings. Code of practice
BS 9991:2015 Fire safety in the design, management and use of residential buildings. Code of practice
BS 9999:2008 Code of practice for fire safety in the design, management and use of buildings
BS 4841-5:2006 Rigid polyisocyanurate (PIR) and polyurethane (PUR) products for building end-use applications Specification for laminated boards (roofboards) with auto-adhesively or separately bonded facings for use as thermal insulation boards for pitched roofs
PD 7974-3:2011 Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin
BS 476-10:2009 Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs
BS 4841-3:2006 Rigid polyisocyanurate (PIR) and polyurethane (PUR) products for building end-use applications Specification for laminated boards (roofboards) with auto-adhesively or separately bonded facings for use as roofboard thermal insulation under built up bituminous roofing membranes
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
BS 4841-4:2006 Rigid polyurethane (PUR) and polyisocyanurate (PIR) products for building end-use applications Specification for laminated insulation boards (roofboards) with auto-adhesively or separately bonded facings for use as roofboard thermal insulation under non-bituminous single-ply roofing membranes
BS 9991:2011 Fire safety in the design, management and use of residential buildings. Code of practice
15/30301829 DC : 0 BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE
11/30203947 DC : 0 BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE
PD 7974-3:2003 Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin (Sub-system 3)
BS 5516-2:2004 Patent glazing and sloping glazing for buildings Code of practice for sloping glazing
03/109613 DC : DRAFT JULY 2003 BS 476-3 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 3: CLASSIFICATION AND METHOD OF TEST FOR EXTERNAL EXPOSURE OF ROOFS TO FIRE
16/30314117 DC : 0 BS 9999 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF BUILDINGS - CODE OF PRACTICE
02/105033 DC : DRAFT AUG 2002 BS 5534 - CODE OF PRACTICE FOR SLATING AND TILING (INCLUDING SHINGLES)

BS 476-3:1958 External fire exposure roof test
ISO 13943:2017 Fire safety — Vocabulary
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
DIN 4102-7:1998-07 FIRE BEHAVIOUR OF BUILDING MATERIALS AND BUILDING COMPONENTS - PART 7: ROOFING; DEFINITIONS, REQUIREMENTS AND TESTING

View more information
£276.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.