• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DD IEC TS 61850-80-1 : DRAFT JAN 2009

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 80-1: GUIDELINE TO EXCHANGING INFORMATION FROM A CDC-BASED DATA MODEL USING IEC 60870-5-101 OR IEC 60870-5-104
Superseded date

31-03-2010

Published date

23-11-2012

FOREWORD
1 Scope and object
2 Normative references
3 Abbreviated terms
4 The mapping architecture
5 Conceptual architectures and
  associated use cases
  5.1 Conceptual architecture of a gateway device
  5.2 Conceptual architecture of an IED
       directly connected to a WAN (optional)
6 Mapping of a device-oriented information
  model to IEC 60870-5-104 or IEC 60870-5-101
  6.1 General
  6.2 Mapping of a device-oriented
       information model reference
  6.3 Logical device class mapping
  6.4 Logical node class mapping
7 Mapping of the common data classes (CDC)
  7.1 List of CDC, type Identifications and
       corresponding mappings for IEC 61850
  7.2 CDC single point status (SPS)
  7.3 CDC double point status (DPS)
  7.4 CDC integer status (INS)
  7.5 CDC protection activated information (ACT)
  7.6 CDC directional protection activation
       information (ACD)
  7.7 CDC Security violation counting (SEC)
  7.8 CDC binary counter reading (BCR)
  7.9 CDC measured value (MV)
  7.10 CDC complex measured value (CMV)
  7.11 CDC Phase to ground related measured
       values of a three-phase system (WYE)
  7.12 CDC phase to phase measured
       values of a three phase system (DEL)
  7.13 CDC sequence (SEQ)
  7.14 CDC harmonic value (HMV)
  7.15 CDC harmonic value for WYE (HWYE)
  7.16 CDC harmonic value for DEL (HDEL)
  7.17 CDC controllable single point (SPC)
  7.18 CDC controllable double point (DPC)
  7.19 CDC controllable integer status (INC)
  7.20 CDC binary controlled step
       position information (BSC)
  7.21 CDC integer-controlled step
       position information (ISC)
  7.22 CDC controllable analogue set
       point information (APC)
  7.23 CDC Single point setting (SPG)
  7.24 CDC integer status setting (ING)
  7.25 CDC analogue settings (ASG)
8 Mapping of services
  8.1 List of service models and
       corresponding mappings
  8.2 Server class mapping
  8.3 Association class mapping
  8.4 Logical node class mapping
  8.5 Data class mapping
  8.6 Setting group class mapping
  8.7 Report control block class mapping
  8.8 Control class mapping
9 Protocol stack selections for IEC 60870-5-101
  and IEC 60870-5-104
  9.1 General
  9.2 Structure of application data
  9.3 IEC 60870-5 interoperability
Annex A (informative) - Use of SCL (substation configuration
                        language) to include IEC 60870-5-101
                        or IEC 60870-5-104 information

Describes a guideline on how to exchange information from a CDC based data model (for example IEC 61850) using IEC 60870-5-101 or IEC 60870-5-104 between substation(s) and control center(s).

Committee
PEL/57
DocumentType
Draft
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Standards Relationship
IEC TS 61850-80-1:2016 Identical

IEC 61850-7-2:2010 Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI)
ISO 9506-2:2003 Industrial automation systems Manufacturing Message Specification Part 2: Protocol specification
IEC 60870-5-4:1993 Telecontrol equipment and systems - Part 5: Transmission protocols - Section 4: Definition and coding of application information elements
IEC 61850-6:2009 Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs
IEC 60870-5-104:2006+AMD1:2016 CSV Telecontrol equipment and systems - Part 5-104: Transmission protocols - Network access for IEC 60870-5-101 using standardtransport profiles
ISO/IEC 8802-3:2000 Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications
ISO 9506-1:2003 Industrial automation systems Manufacturing Message Specification Part 1: Service definition
IEC 60870-5-101:2003+AMD1:2015 CSV Telecontrol equipment and systems - Part 5-101: Transmissionprotocols - Companion standard for basic telecontrol tasks
IEC 60870-5-5:1995 Telecontrol equipment and systems - Part 5: Transmission protocols - Section 5: Basic application functions
IEC 61850-8-1:2011 Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3
IEC 61850-7-3:2010 Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes
IEEE 754-2008 REDLINE IEEE Standard for Floating-Point Arithmetic
IEC 60870-5-3:1992 Telecontrol equipment and systems - Part 5: Transmission protocols - Section 3: General structure of application data
IEC 61400-25-2:2015 Wind turbines - Part 25-2: Communications for monitoring and control of wind power plants - Information models

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.