DIN EN 15193:2008-01
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
ENERGY PERFORMANCE OF BUILDINGS - ENERGY REQUIREMENTS FOR LIGHTING
Hardcopy , PDF
01-10-2017
English
01-01-2008
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Calculating energy used for lighting
4.1 Total energy used for lighting
4.1.1 Total estimated energy
4.1.2 Total annual energy used for lighting
4.2 Lighting Energy Numeric Indicator (LENI)
5 Metering
5.1 General
5.2 Load segregation
5.3 Remote metering
6 Calculation of lighting energy in buildings
6.1 Installed lighting power
6.1.1 General
6.1.2 Luminaire
6.1.3 Luminaire power (P[i])
6.1.4 Parasitic powers (P[ci] and P[ei])
6.2 Calculation methods
6.2.1 Quick method
6.2.2 Comprehensive method
6.2.3 Determination of constant illuminance factor F[c]
7 Benchmark of lighting energy requirements
8 Lighting design and practice
Annex A (informative) Metering of lighting circuit
Annex B (informative) Measurement method of total power of
luminaires and associated parasitic power
B.1 Introduction
B.2 Test measurement of luminaire power during normal
operation
B.3 Standard test conditions
B.4 Electrical measuring instruments
B.5 Test luminaires
B.6 Test voltage
B.7 Luminaire power (P[i])
B.8 Luminaire parasitic power with lamps off (P[pi])
B.9 Emergency lighting luminaire parasitic input power
(P[ei])
B.10 Lighting controls standby parasitic power (P[ci])
B.11 Default luminaire power for existing lighting
installations
B.12 Default parasitic energy for existing lighting
installations
Annex C (informative) Determination of the daylight dependency
factor F[D,n]
C.1 General
C.2 Building segmentation: Spaces benefiting from daylight
C.3 Daylight supply
C.3.1 Vertical fagades
C.3.2 Rooflights
C.4 Daylight dependent artificial lighting control, F[D,c]
C.5 Monthly method
Annex D (informative) Determination of occupancy dependency
factor F[o]
D.1 Introduction
D.2 Detailed determination of F[o]
D.3 Motivation for the choice of F[o] functions
Annex E (informative) Determination of the constant illuminance
factor F[c]
E.1 Introduction
E.2 Power for constant illuminance factor
E.3 Constant illuminance factor (F[c])
Annex F (informative) Benchmark values and lighting design criteria
Annex G (informative) Default values
G.1 The default values for annual operating hours relating
to building type are given in Table G.1
Annex H (informative) Other considerations
H.1 Individual dimming
H.2 Algorithmic lighting
H.3 Light pipes
H.4 Lighting installations with scene setting
H.5 Daylight guidance
H.5.1 Vertical fagades
H.5.2 Rooflights
Annex I (informative) List of Symbols
Bibliography
National Annex NA (informative) Comparison of calculation methods
used in Germany with those specified in this
European Standard
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.