Vorwort
1 Anwendungsbereich
2 Normative Verweisungen
3 Definitionen, Symbole und Abkürzungen
  3.1 Definitionen
  3.2 Symbole und Abkürzungen
4 Klassifikation
  4.1 Filtergruppen
  4.2 Filterklassen
5 Anforderungen
  5.1 Allgemeines
  5.2 Werkstoffe
  5.3 Nennvolumenstrom
  5.4 Druckdifferenz
  5.5 Filtrationsleistung
6 Prüfverfahren
  6.1 Prüfstände
  6.2 Prüfbedingungen
  6.3 Prüfaerosol
  6.4 Verfahrensübersicht
  6.5 Prüfverfahren
7 Filterbeurteilung, Dokumentation
8 Kennzeichnung

This standard is included in DIN Handbook 85.

DevelopmentNote
Supersedes DIN 24184 and DIN 24183-1. (05/2001) DRAFT 2017 issued in July 2017. (07/2017)
DocumentType
Standard
Pages
22
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded

Standards Relationship
SN EN 1822-1 : 2010 Identical
NS EN 1822-1 : 2009 Identical
I.S. EN 1822-1:2009 Identical
ONORM EN 1822-1 : 2011 Identical
EN 1822-1:2019 Identical
NEN EN 1822-1 : 2009 Identical
BS EN 1822-1:2009 Identical
UNE-EN 1822-1:2010 Identical
UNI EN 1822-1 : 2010 Identical
NF EN 1822-1 : 2010 Identical
EN 1822-1:2009 Identical
NBN EN 1822-1 : 2010 Identical

KTA 1503.1 : 2016(R2017) MONITORING THE DISCHARGE OF RADIOACTIVE GASES AND AIRBORNE RADIOACTIVE PARTICULATES - PART 1: MONITORING THE DISCHARGE OF RADIOACTIVE MATTER WITH THE STACK EXHAUST AIR DURING SPECIFIED NORMAL OPERATION
VDI 3677 Blatt 2:2004-02 Filtering separators - Depth fiber filters
VDI/GVSS 6202 Blatt 1:2013-10 Contaminated buildings and technical installations - Demolition, refurbishing and maintenance
VDI 4300 Blatt 11:2013-12 Measurement of indoor air pollution - Measurement strategies for determination of airborne particles in indoor environment - PM-fraction
VDI 3678 Blatt 2:2010-12 Electrostatic precipitators - Process air and indoor air cleaning
VDI 6032 Blatt 1:2015-05 Ventilation and indoor-air quality in vehicles - Hygiene requirements for ventilation and air-conditioning systems
VDI 3491 Blatt 15:1996-12 Particulate matter measurement - Generation of test aerosols - Dilution systems with continuous volumetric flow
VDI 6022 Blatt 5:2016-11 Ventilation and indoor-air quality - Avoidance of allergenic exposure - Requirements regarding the testing and evaluation of technical products and components affecting the indoor air
VDI 6300 Blatt 1:2016-05 Genetic engineering operations in genetic engineering facilities - Guidance on safe operation of genetic engineering facilities
VDI 2464 Blatt 3:2012-07 Ambient air measurement - Indoor air measurement - Measurement of polybrominated diphenylether, hexabromocyclododecane and hexabromobenzene by GC/MS
VDI 2083 Blatt 3:2005-07 Cleanroom technology - Metrology and test methods
DIN HDBK 85 : 11ED 2017 RAUMLUFTTECHNISCHE ANLAGEN VOB/STLB-BAU - VOB TEIL C: ATV DIN 18299, ATV DIN 18379
DIN 18379:2016-09 GERMAN CONSTRUCTION CONTRACT PROCEDURES (VOB) - PART C: GENERAL TECHNICAL SPECIFICATIONS IN CONSTRUCTION CONTRACTS (ATV) - INSTALLATION OF AIR CONDITIONING SYSTEMS
DIN EN 16913:2015-10 (Draft) AMBIENT AIR - STANDARD METHOD FOR MEASUREMENT OF NO[3][-], SO[4][2-], CL[-], NH[4][+], NA[+], K[+], MG[2+], CA[2+] IN PM2,5 AS DEPOSITED ON FILTERS

EN 1822-5:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements
EN 1822-2:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 2: Aerosol production, measuring equipment, particle counting statistics
EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
ISO 14644-3:2005 Cleanrooms and associated controlled environments Part 3: Test methods
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
EN 1822-3:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media
EN 1822-4:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method)
EN 14799 : 2007 AIR FILTERS FOR GENERAL AIR CLEANING - TERMINOLOGY
EN ISO 14644-3:2005 CLEANROOMS AND ASSOCIATED CONTROLLED ENVIRONMENTS - PART 3: TEST METHODS

View more information
£91.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.