• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DIN EN 54-30 E : 2015

Current
Current

The latest, up-to-date edition.

FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTISENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2015

National foreword
National Annex NA (informative) - Bibliography
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Test and evaluation methods
6 Assessment and verification of constancy of
  performance (AVCP)
7 Classification
8 Marking, labelling and packaging
Annex A (normative) - Gas test chamber for CO
        response value and cross-sensitivity to
        chemical agents
Annex A (normative) - Gas test chamber for CO
        response value and cross-sensitivity to
        chemical agents
Annex C (normative) - Measuring instruments
        for smoke and CO
Annex D (informative) - Establishing exposure
        levels of chemical agents
Annex E (normative) - Heat tunnel for heat response
        value
Annex F (normative) - Smouldering (pyrolysis)
        wood fire (TF2)
Annex G (normative) - Glowing smouldering
        cotton fire (TF3)
Annex H (normative) - Open plastics (polyurethane)
        fire (TF4)
Annex I (normative) - Liquid (heptane) fire (TF5)
Annex J (informative) - Information concerning
        the construction of the gas test chamber
Annex K (informative) - Construction of the
        heat tunnel
Annex L (informative) - Apparatus for impact test
Annex ZA (informative) - Clauses of this European
         Standard addressing the provisions of the EU
         Construction Products Regulation
Bibliography

Defines requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in and around buildings (see EN 54-1:2011), incorporating in one mechanical enclosure at least one carbon monoxide sensor and at least one heat sensor and where the overall fire detection performance is determined utilizing the combination of the detected phenomena.

DocumentType
Standard
Pages
99
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Current

Standards Relationship
EN 54-30:2015 Identical

ISO 209:2007 Aluminium and aluminium alloys — Chemical composition
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
VDE 0833-2 :2017-10 ALARM SYSTEMS FOR FIRE, INTRUSION AND HOLD UP - PART 2: REQUIREMENTS FOR FIRE ALARM SYSTEMS
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 54-5:2017 Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
305/2011 : 2011 AMD 2 2014 REGULATION (EU) NO 305/2011 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 2011 LAYING DOWN HARMONISED CONDITIONS FOR THE MARKETING OF CONSTRUCTION PRODUCTS AND REPEALING COUNCIL DIRECTIVE 89/106/EEC (TEXT WITH EEA RELEVANCE)
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
DIN VDE 0833-2:2017-10 ALARM SYSTEMS FOR FIRE, INTRUSION AND HOLD UP - PART 2: REQUIREMENTS FOR FIRE ALARM SYSTEMS
EN 54-26:2015 Fire detection and fire alarm systems - Part 26: Carbon monoxide detectors - Point detectors
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
£186.37
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.