DIN EN ISO 8638 E : 2014

Current

Current

The latest, up-to-date edition.

CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - EXTRACORPOREAL BLOOD CIRCUIT FOR HAEMODIALYSERS, HAEMODIAFILTERS AND HAEMOFILTERS (ISO 8638:2010)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2014

National foreword
National Annex NA (informative) - Bibliography
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test methods
6 Labelling
Bibliography
Annex ZA (informative) - Relationship between this
         European Standard and the Essential
         Requirements of EU Directive 93/42/EEC on
         medical devices

Defines requirements for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators (hereafter referred to as 'the device') and (integral and non-integral) transducer protectors that are intended for use in haemodialysis, haemodiafiltration and haemofiltration.

DevelopmentNote
Supersedes DIN EN 1283 E. (04/2014)
DocumentType
Standard
Pages
23
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Current
Supersedes

Standards Relationship
EN ISO 8638:2014 Identical
ISO 8638:2010 Identical

DIN EN ISO 80369-7 E : 2017 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 7: CONNECTORS FOR INTRAVASCULAR OR HYPODERMIC APPLICATIONS (ISO 80369-7:2016, CORRECTED VERSION 2016-12-01)
DIN EN ISO 80369-7:2017-10 Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications (ISO 80369-7:2016, Corrected version 2016-12-01)

ISO 11137-1:2006 Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 10993-4:2017 Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood
ISO 15223-2:2010 Medical devices — Symbols to be used with medical device labels, labelling, and information to be supplied — Part 2: Symbol development, selection and validation
ISO 8637:2010 Cardiovascular implants and extracorporeal systems Haemodialysers, haemodiafilters, haemofilters and haemoconcentrators
ISO/TS 17665-2:2009 Sterilization of health care products — Moist heat — Part 2: Guidance on the application of ISO 17665-1
ISO 14937:2009 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
ISO 11135-1:2007 Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 10993-11:2017 Biological evaluation of medical devices — Part 11: Tests for systemic toxicity
ISO 11137-3:2017 Sterilization of health care products — Radiation — Part 3: Guidance on dosimetric aspects of development, validation and routine control
ISO 10993-7:2008 Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals
ISO 7864:2016 Sterile hypodermic needles for single use — Requirements and test methods
ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
DIN EN ISO 10993-11 E : 2009 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 11: TESTS FOR SYSTEMIC TOXICITY
ISO/TS 11135-2:2008 Sterilization of health care products Ethylene oxide Part 2: Guidance on the application of ISO 11135-1
ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
ISO 594-2:1998 Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings
ISO 15223-1:2016 Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements
ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices

View more information
£82.54
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.