EN 25136 : 1993

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

ACOUSTICS - DETERMINATION OF SOUND POWER RADIATED INTO A DUCT BY FANS - IN-DUCT METHOD
Superseded date

01-04-2003

Published date

12-01-2013

Cooperating organizations
National foreword
Foreword
Method
1. Scope
2. Normative references
3. Definitions and symbols
4. Test facilities and instrumentation
5. Test arrangements
6. Test procedure
7. Calculations
8. Information to be recorded
9. Information to be reported
Annexes
A. (normative) Computational procedures for calculating
     A-weighted sound power level from octave or one-third
     octave band power levels
B. (normative) Determination of the signal-to-noise
     ratio of sound to turbulence noise in the test duct
C. (informative) Guidelines for the design and
     construction of an anechoic termination
D. (informative) Evaluation of performance of anechoic
     terminations
E. (informative) Example of a sampling tube
F. (informative) Measurement of the swirl component
G. (informative) Bibliography
Tables
1. Precision of the method of measurement
2. Cross-sectional areas of ducts
3. Maximum pressure reflection coefficients
4. Limiting values of the directivity constant K
5. Flow velocity correction, C3, in decibels, for the
     frequency response of the sampling tube
6. Modal correction, C4, for the frequency response of
     the sampling tube
7. Radial positions of the sampling tube
A.1 Values of Cj
B.1 Maximum allowable difference between the sound
     pressure level readings of a microphone fitted with
     a nose cone, LPNC, and of a microphone fitted with
     a sampling tube, LPST, as a function of the
     turbulence noise suppression delta Lt, of the
     sampling tube, for a minimum signal-to-noise ratio
     of sound to turbulence noise of 6 dB
E.1 Turbulence noise suppression, delta Lt, of the
     typical sampling tube shown in figure E.1 as
     compared with a 13 mm nose cone
Figures
1. Test arrangement and limiting dimensions of test
     ducts, intermediate ducts and transitions
2. Limiting curves for the directivity of the sampling
     tube (broad-band noise of one-third octave bandwidth)
3. Radial position of the sampling tube
C.1 Examples of anechoic terminations
C.2 Example of one-sided anechoic terminations
C.3 Example of anechoic termination
C.4 Example of two-sided anechoic termination
C.5 Examples of throttling sections
E.1 Schematic drawing of a typical sampling tube
E.2 Typical mountings of microphone and sampling tube
National annexes
NA (informative) Committees responsible
NB (informative) Cross-reference

Specifies a method for testing ducted fans to determine the sound power radiated into an anechoically terminated duct on the inlet and/or outlet side of the equipment. Applies to fans that emit steady, broad band, narrow band and discrete frequency sound. Coverage includes: definitions and symbols; test facilities and instrumentation; information to be recorded; information to be reported. Also give detailed tables and annexes.

Committee
CEN/TC 211
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
NBN EN 25136 : 1995 Identical
UNE-EN 25136:1995 Identical
NF EN 25136 : 1994 Identical
BS EN 25136:1994 Identical
UNI EN 25136 : 1995 Identical
I.S. EN 25136:1994 Identical
SNV DIN EN 25136 : 1994 Identical
NS ISO 5136 : 1ED 1994 Identical
SNV NF EN 25136 : 1994 Identical
ISO 5136:2003 Identical
DIN EN 25136:1994-02 Identical

00/714693 DC : DRAFT OCT 2000 PREN 13141-7 - VENTILATION FOR BUILDINGS - PERFORMANCE TESTING OF COMPONENTS/PRODUCTS FOR RESIDENTIAL VENTILATION - PART 7: PERFORMANCE TESTING A MECHANICAL SUPPLY AND EXHAUST VENTILATION UNITS (INCLUDING HEAT RECOVERY) FOR MECHANICAL VENTILATION SYSTEMS INTENDED FOR SINGLE FAMILY DWELLINGS
03/316891 DC : DRAFT OCT 2003 EN 13053 - VENTILATION FOR BUILDINGS - AIR HANDLING UNITS - RATINGS AND PERFORMANCE FOR UNITS, COMPONENTS AND SECTIONS

ISO 266:1997 Acoustics — Preferred frequencies
IEC 60225:1966 Octave, half-octave and third-octave band filters intended for the analysis of sounds and vibrations
ISO 7235:2003 Acoustics — Laboratory measurement procedures for ducted silencers and air-terminal units — Insertion loss, flow noise and total pressure loss
ISO 5221:1984 Air distribution and air diffusion Rules to methods of measuring air flow rate in an air handling duct
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV Sound level meters

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.