EN 50131-10:2014

Current

Current

The latest, up-to-date edition.

Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT)

Published date

06-06-2014

Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 General requirements
5 Security grade
6 Environmental performance
7 Functional requirements
8 Product documentation
9 Marking and labelling
10 Tests
Annex A (informative) - Classification of SPT
Bibliography

This European Standard specifies requirements for SPT used in I&HAS to transmit alarm and other messages to a location remote from the supervised premises.

NOTE 1Requirements for the transmission of alarms are given in the EN/TS 50136 series of standards. EN 50136 2 gives requirements for SPT for use in any type of alarm system (e.g. fire, social care, intrusion, etc).

This European Standard gives specific requirements for SPT used in Intrusion and Hold-up Alarm Systems (I&HAS) and should be used in combination with EN 50136 2.

The requirements of this European Standard apply to different types of SPT including separate SPT, SPT located within the housings of other I&HAS components and also when the SPT functionality is integrated with the CIE or other parts of an I&HAS.

NOTE 2To facilitate the differing requirements this European Standard includes a categorisation with three types (X, Y and Z).

This European Standard does not give requirements for the ATS network or performance.

Committee
CLC/TC 79
DevelopmentNote
Supersedes PREN 50131-10. (06/2014)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

S.R. CLC/TS 50131-9:2014 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 9: ALARM VERIFICATION - METHODS AND PRINCIPLES
CLC/TS 50131-9:2014 Alarm systems - Intrusion and hold-up systems - Part 9: Alarm verification - Methods and principles
PD CLC/TS 50131-9:2014 Alarm systems. Intrusion and hold-up systems Alarm verification. Methods and principles

EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
EN 50136-2:2013 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT)
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 50136-1:2012 Alarm systems - Alarm transmission systems and equipment - Part 1: General requirements for alarm transmission systems
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 50131-3:2009 Alarm systems - Intrusion and hold-up systems - Part 3: Control and indicating equipment
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.