• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 50200:2015

Current
Current

The latest, up-to-date edition.

Method of test for resistance to fire of unprotected small cables for use in emergency circuits
Published date

04-12-2015

European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Test environment
5 Test apparatus
6 Verification procedure for source of heat
7 Test sample (Electric power and control
  cables with rated voltage up to and including
  600 V/1000 V)
8 Cable test procedure (Electric power and
  control cables with rated voltage up to and
  including 600 V/1000 V)
9 Test report (Electric power and control cables
  with rated voltage up to and including
  600 V/1000 V)
Annex A (informative) - Guidance on the choice of
        recommended test equipment
Annex B (normative) - Field of direct application
        and extended application of test results
        (Electric power and control cables with
        rated voltage up to and including
        600 V/1000 V)
Annex C (normative) - Fuse characteristic curve
Annex D (informative) - Information regarding
        classification
Annex E (informative) - Guidance for using optional
        water spray protocol
Bibliography

This European Standard specifies the test method for cables designed to have intrinsic resistance to fire and intended for use as emergency circuits for alarm, lighting and communication purposes.This European Standard is applicable to cables for emergency circuits of rated voltage not exceeding 600 V/1 000 V, including those of rated voltage below 80 V and optical fibre cables.This European Standard includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600 V/1 000 V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to copper data and telecom cables and optical cables are given in the relevant standards of CLC/TC 46X and CLC/TC 86A.The test method is limited to cables with an overall diameter not exceeding 20 mm.The test method is based on the direct impingement of flame from a propane burner giving a constant temperature attack of a notional 842 °C. It is intended to be used for cables for emergency circuits suitable for alarm, emergency lighting and communication. NOTEWhen the test method is used in support of EN 13501-3, it only applies to cables of less than 20 mm diameter, and, for metallic conductor cables, to those with conductor sizes up to and including 2,5 mm². For optical cables, only the less than 20 mm diameter limit applies.This European Standard includes (Annex B) the field of direct application and rules for extended application of test results (EXAP). Details regarding classification using data from this test are given in EN 13501-3 . Information regarding classification is given in Annex D.This European Standard also includes informative guidance (Annex E) on a means of applying a water spray to the cable during the test. Such a requirement may be a feature of particular product standards.

Committee
CLC/TC 20
DevelopmentNote
Supersedes PREN 50200. (12/2015)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

Standards Relationship
I.S. EN 50200:2015 Identical
NEN EN 50200 : 2015 Identical
CEI EN 50200 : 2016 Identical
PN EN 50200 : 2016 Identical
SN EN 50200 : 2015 Identical
SANS 50200 : 1ED 2011 Identical
UNE-EN 50200:2016 Identical
SS-EN 50200 : 2016 Identical
BS EN 50200:2015 Identical
NBN EN 50200 : 2016 Identical
NF EN 50200 : 2016 Identical
DIN EN 50200 : 2016 Identical
VDE 0482-200 : 2016 Identical
SANS 50200:2022 Identical

PREN 50290-4-2 : DRAFT 2013 COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE
07/30168378 DC : 0 BS EN 50289-4-16 - COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 4-16: ENVIRONMENTAL TEST METHODS - CIRCUIT INTEGRITY UNDER FIRE CONDITIONS
12/30261347 DC : 0 BS EN 50582 - METHOD OF TEST FOR RESISTANCE TO FIRE OF UNPROTECTED OPTICAL FIBRE CABLES FOR USE IN EMERGENCY CIRCUITS (DIAMETER LESS THAN OR EQUAL TO 20 MM)
PD CEN/TS 54-32:2015 Fire detection and fire alarm systems Planning, design, installation, commissioning, use and maintenance of voice alarm systems
UNE-EN 50582:2016 Procedure to assess the circuit integrity of optical fibres in a cable under resistance to fire testing
BS EN 50553 : 2012 RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK
I.S. EN 50577:2015 ELECTRIC CABLES - FIRE RESISTANCE TEST FOR UNPROTECTED ELECTRIC CABLES (P CLASSIFICATION)
S.R. HD 60364-5-56:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES
EN 1366-11:2018 Fire resistance tests for service installations - Part 11: Fire protective systems for cable systems and associated components
EN 50582:2016 Procedure to assess the circuit integrity of optical fibres in a cable under resistance to fire testing
I.S. EN 50553:2012 RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK
BS EN 50582:2016 Procedure to assess the circuit integrity of optical fibres in a cable under resistance to fire testing
BS EN 50289-4-16:2016 Communication cables. Specifications for test methods Environmental test methods. Circuit integrity under fire conditions
BS EN 1366-5:2010 Fire resistance tests for service installations Service ducts and shafts
BS EN 50355:2013 Railway applications. Railway rolling stock cables having special fire performance. Guide to use
UNE-EN 50289-4-16:2016 Communication cables - Specifications for test methods - Part 4-16: Environmental test methods - Circuit integrity under fire conditions
S.R. CEN/TS 54-32:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 32: PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE OF VOICE ALARM SYSTEMS
PREN 50553 : DRAFT 2010 RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK
CEI EN 50343 : 2015 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
I.S. EN 50289-4-16:2016 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS PART 4-16: ENVIRONMENTAL TEST METHODS - CIRCUIT INTEGRITY UNDER FIRE CONDITIONS
UNE-HD 60364-5-56:2010 Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services
CEI EN 50362 : 2003 METHOD OF TEST FOR RESISTANCE TO FIRE OF LARGER UNPROTECTED POWER AND CONTROL CABLES FOR USE IN EMERGENCY CIRCUITS
BS EN 50290-4-2:2014 Communication cables General considerations for the use of cables. Guide to use
02/540530 DC : DRAFT OCT 2003 BS 7346-6 - COMPONENTS FOR SMOKE AND HEAT CONTROL SYSTEMS - PART 6: CABLE SYSTEMS
13/30277639 DC : 0 BS EN 50355 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
12/30235292 DC : 0 BS EN 50343 - RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
UNE-EN 50577:2016 Electric cables - Fire resistance test for unprotected electric cables (P classification)
CEI EN 50355 : 2014 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
CEI EN 50582 : 1ED 2017 PROCEDURE TO ASSESS THE CIRCUIT INTEGRITY OF OPTICAL FIBRES IN A CABLE UNDER RESISTANCE TO FIRE TESTING
BS EN 50343 : 2014 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
PREN 50355 : DRAFT 2012 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
EN 50577:2015 Electric cables - Fire resistance test for unprotected electric cables (P classification)
PREN 50577 : DRAFT 2012 ELECTRIC CABLES - FIRE RESISTANCE TEST FOR UNPROTECTED ELECTRIC CABLES (P CLASSIFICATION)
I.S. HD 60364-5-56:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES (IEC 60364-5-56:2009 (EQV))
CEN/TS 54-32:2015 Fire detection and fire alarm systems - Part 32: Planning, design, installation, commissioning, use and maintenance of voice alarm systems
PREN 50289-4-16 : DRAFT 2016 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 4-16: ENVIRONMENTAL TEST METHODS - CIRCUIT INTEGRITY UNDER FIRE CONDITIONS
EN 50362:2003 Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
13/30268920 DC : 0 BS EN 50290-4-2 ED.2 PREN 50290-4-2 ED.2 - COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE
HD 60364-5-56:2010/A12:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES
I.S. EN 50362:2003 METHOD OF TEST FOR RESISTANCE TO FIRE OF LARGER UNPROTECTED POWER AND CONTROL CABLES FOR USE IN EMERGENCY CIRCUITS
CEI EN 50289-4-16 : 2013 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 4-16: ENVIRONMENTAL TEST METHODS - CIRCUIT INTEGRITY UNDER FIRE CONDITIONS
UNI EN 1366-5 : 2010 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 5: SERVICE DUCTS AND SHAFTS
I.S. EN 50343:2014 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
I.S. EN 50290-4-2:2014 COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE
EN 50355:2013 Railway applications - Railway rolling stock cables having special fire performance - Guide to use
12/30260450 DC : 0 BS EN 50577 - ELECTRIC CABLES - FIRE RESISTANCE TEST FOR UNPROTECTED ELECTRIC CABLES (P CLASSIFICATION)
UNE-EN 50290-4-2:2016 Communication cables - Part 4-2: General considerations for the use of cables - Guide to use
10/30216933 DC : 0 BS EN 50553 - RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK
BS EN 50577:2015 Electric cables. Fire resistance test for unprotected electric cables (P classification)
07/30166835 DC : 0 BS EN 1366-5 - FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 5: SERVICE DUCTS AND SHAFTS
16/30336756 DC : 0 BS EN 50289-4-16 - COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 4-16: ENVIRONMENTAL TEST METHODS - CIRCUIT INTEGRITY UNDER FIRE CONDITIONS
DIN EN 1366-5:2010-06 Fire resistance tests for service installations - Part 5: Service ducts and shafts
EN 1366-5:2010 Fire resistance tests for service installations - Part 5: Service ducts and shafts
BS EN 50362:2003 Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
I.S. EN 1366-5:2010 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 5: SERVICE DUCTS AND SHAFTS
I.S. EN 50355:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
EN 50553 : 2012 AMD 1 2016 RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK
EN 50289-4-16:2016 Communication cables - Specifications for test methods - Part 4-16: Environmental test methods - Circuit integrity under fire conditions
EN 50290-4-2:2014 Communication cables - Part 4-2: General considerations for the use of cables - Guide to use
EN 50343 : 2014 AMD 1 2017 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING

IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
ISO 13943:2017 Fire safety — Vocabulary
EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
IEC 60269-3:2010+AMD1:2013 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
EN 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
EN 13501-3:2005+A1:2009 Fire classification of construction products and building elements - Part 3: Classification using data from fire resistance tests on products and elements used in building service installations: fire resisting ducts and fire dampers
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
IEC 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.