Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables

Published date

27-06-2008

EN 50264-3-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: • 0,6/1 kV unscreened, unsheathed (1 mm2 to 400 mm2); • 1,8/3 kV unscreened, unsheathed (1,5 mm2 to 400 mm2); • 1,8/3 kV unscreened, sheathed (1,5 mm2 to 400 mm2); • 3,6/6 kV unscreened, sheathed (2,5 mm2 to 400 mm2). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90° C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-3-1 should be read in conjunction with Part 1 “General requirements”.

Committee
CLC/TC 20
DevelopmentNote
To be read in conjunction with EN 50264-1. (08/2008)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

BS EN 50264-2-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables
UNE-EN 50467:2012 Railway applications - Rolling stock - Electrical connectors, requirements and test methods
I.S. EN 50628:2016 ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES
I.S. EN 50467:2011 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
UNE-EN 50264-3-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
05/30137080 DC : 0 EN 50264-2-2 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATON - MULTICORE CABLES
BS EN 50264-2-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables
CEI EN 50467 : 2013 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
PREN 50467 : DRAFT 2009 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
BS EN 50355:2013 Railway applications. Railway rolling stock cables having special fire performance. Guide to use
I.S. EN 50264-3-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
13/30277639 DC : 0 BS EN 50355 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
CEI EN 50264-2-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
CEI EN 50355 : 2014 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
PREN 50355 : DRAFT 2012 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
CEI EN 50264-2-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
05/30136253 DC : 0 EN 50264-2-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
UNE-EN 50264-2-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
I.S. EN 50264-2-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
CEI EN 50264-3-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
UNE-EN 50264-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
05/30137088 DC : 0 EN 50264-3-2 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATON WITH REDUCED DIMENSIONS - MULTICORE CABLES
12/30235292 DC : 0 BS EN 50343 - RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
14/30316181 DC : 0 BS EN 50628 - ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES
BS EN 50264-3-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables
05/30136249 DC : 0 EN 50264-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
CEI EN 50264-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
PREN 50628 : DRAFT 2014 ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES
I.S. EN 50264-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS EN 50628:2016 Erection of electrical installations in underground mines
EN 50355:2013 Railway applications - Railway rolling stock cables having special fire performance - Guide to use
09/30208429 DC : 0 BS EN 50467 - RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
BS EN 50264-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance General requirements
BS EN 50467:2011 Railway applications. Rolling stock. Electrical connectors, requirements and test methods
UNE-EN 50264-2-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
I.S. EN 50264-2-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
I.S. EN 50355:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE
IEC 62847:2016 Railway applications - Rolling stock - Electrical connectors - Requirements and test methods
EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
EN 50628:2016 Erection of electrical installations in underground mines
EN 50467 : 2011 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS

EN 10002-1 : 2001 METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE
EN 50266-2-4 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-4: PROCEDURES - CATEGORY C
EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
IEC 60228:2004 Conductors of insulated cables
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 61034-2:2005/A1:2013 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013)
HD 308 S2:2001 Identification of cores in cables and flexible cords
IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
EN 50305:2002 Railway applications - Railway rolling stock cables having special fire performance - Test methods
EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
EN 60811-2-1 : 98 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
EN 50355:2013 Railway applications - Railway rolling stock cables having special fire performance - Guide to use
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
EN 50266-2-5 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-5: PROCEDURES - SMALL CABLES - CATEGORY D
IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.