• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 50288-7:2005

Current

Current

The latest, up-to-date edition.

Multi-element metallic cables used in analogue and digital communication and control - Part 7: Sectional specification for instrumentation and control cables

Published date

30-09-2005

1 Scope
2 Normative references
3 Definitions, symbols and abbreviations
4 Cable construction
  4.1 Conductor
  4.2 Insulation
  4.3 Cable elements
  4.4 Identification of cabling elements
  4.5 Screening of cabling elements
  4.6 Cable make-up
  4.7 Filling compound
  4.8 Interstitial fillers
  4.9 Screening of the cable core
  4.10 Moisture barriers
  4.11 Protective wrappings
  4.12 Inner sheath
  4.13 Bedding layers
  4.14 Metallic protection
  4.15 Integral suspension strand
  4.16 Outer sheathing
  4.17 Fauna protection
  4.18 Chemical and/or environmental protection
       4.18.1 Lead sheath
       4.18.2 Multi-layer sheath
5 Test methods and requirements for completed
  cables
  5.1 Electrical tests
       5.1.1 Low frequency and d.c. electrical
              measurements
  5.2 Mechanical tests
  5.3 Environmental tests
  5.4 Fire performance test methods
Annex A (normative) - Insulation thickness and concentricity -
        Selection of samples and evaluation of results
Annex B (normative) - Copper braid screening
Annex C (normative) - Determination of cable dimensions
Annex D (informative) - Thermocouple extension and compensating
        conductors

This sectional specification covers multi-element cables suitable for connecting instruments and control systems for analogue or digital signal transmission. They may or may not be screened and optionally may incorporate armouring and/or moisture or environmental protection layers. The cables shall have a mechanically robust construction and electrical transmission handling properties. The electrical, mechanical, transmission and environmental performance characteristics of the cables, related to their reference test methods are detailed. This sectional specification is to be read in conjunction with EN 50288-1, which contains the essential provisions for its application. Cables covered by this specification have maximum rated voltages of 90 V, 300 V and 500 V a.c. These cables shall not be connected directly to mains electricity supply or other low impedance sources. Multi-element cables for use in analogue, digital and control circuits are not designed to be used for power supply. These cables should be installed in accordance with the applicable local and national regulations. Cables intended to have limited circuit integrity in a fire are not covered by this specification, but they are however under consideration for future editions. There may be occasions when cables are required to have higher operating temperature ratings than those provided by using materials specified by the EN 50290 series. Suitable alternative materials are under consideration.

DevelopmentNote
To be read in conjunction with EN 50288-1. (10/2005)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

UNE-EN 50290-2-29:2016 Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
CEI EN 50290-2-29 : 2002 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
EN 1366-11:2018 Fire resistance tests for service installations - Part 11: Fire protective systems for cable systems and associated components
EN 50290-2-29:2016 Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
I.S. EN 50290-2-29:2016 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
PREN 1366-11 : DRAFT 2014 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 11: FIRE PROTECTIVE SYSTEMS FOR CABLE SYSTEMS AND ASSOCIATED COMPONENTS
16/30336762 DC : 0 BS EN 50290-2-29 - COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
IEEE 45.8-2016 IEEE Recommended Practice for Electrical Installations on Shipboard--Cable Systems
14/30299756 DC : 0 BS EN 1366-11 - FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 11: FIRE PROTECTIVE SYSTEMS FOR CABLE SYSTEMS AND ASSOCIATED COMPONENTS
BS EN 50290-2-29:2016 Communication cables Common design rules and construction. Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
PREN 50290-2-29 : DRAFT 2016 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES

EN 10218-1:2012 Steel wire and wire products - General - Part 1: Test methods
IEC 60228:2004 Conductors of insulated cables
EN 10244-2:2009 Steel wire and wire products - Non-ferrous metallic coatings on steel wire - Part 2: Zinc or zinc alloy coatings
EN 50307:2002 Lead and lead alloys - Lead and lead alloy sheaths and sleeves of electric cables
IEC 60584-3:2007 Thermocouples - Part 3: Extension and compensating cables - Tolerances and identification system
EN 10257-1:2011 Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables
EN 60708:2005/AC:2016-08 LOW-FREQUENCY CABLES WITH POLYOLEFIN INSULATION AND MOISTURE BARRIER POLYOLEFIN SHEATH
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
IEC 60189-2:2007 Low-frequency cables and wires with PVC insulation and PVC sheath - Part 2: Cables in pairs, triples, quads and quintuples for inside installations
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
IEC 60708:2005 Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
HD 446.3 : 200S1 THERMOCOUPLES - EXTENSION AND COMPENSATING CABLES - TOLERANCES AND IDENTIFICATION SYSTEM

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.