1 Scope
2 Normative references
3 Physical quantities, units and constants
  3.1 Physical quantities
  3.2 Constants
4 Definitions
5 Measurement system specifications
  5.1 General requirements
  5.2 Phantom specifications (shell and liquid)
  5.3 Specifications of the SAR measurement
      equipment
  5.4 Scanning system specifications
  5.5 Mobile phone holder specifications
  5.6 Other equipment
6 Protocol for SAR assessment
  6.1 Measurement preparation
  6.2 Tests to be performed
  6.3 Measurement procedure
  6.4 Post-processing
7 Uncertainty assessment
  7.1 General requirements
  7.2 Components contributing to uncertainty
  7.3 Uncertainty assessment
8 Measurement report
  8.1 General
  8.2 Items to be recorded in the test report
Annex A (informative) Phantom specifications
        A.1 Rationale for the phantom shape
        A.2 Tissue equivalent liquids
        A.3 Preparation of tissue equivalent
            material
        A.4 Measurement of the dielectric
            properties
Annex B (informative) Calibration of the measurement
                      equipment (linearity, isotropy,
                      sensitivity) and uncertainty
                      assessment
        B.1 Introduction
        B.2 Assessment of the sensitivity of the
            dipolar sensors
        B.3 Isotropy
        B.4 Linearity
        B.5 Lower detection limit
        B.6 Boundary effects
        B.7 Response time
Annex C (informative) Post-processing techniques and
                      uncertainty assessment
        C.1 Extrapolation and interpolation schemes
        C.2 Averaging scheme and maximum finding
Annex D (informative) Measurement system validation
        D.1 Simplified performance checking
        D.2 System validation

Applies to any electromagnetic field (EM) transmitting devices intended to be used with the radiating part of the equipment in close proximity to the human ear including mobile phones, cordless phones, etc. The frequency range is 300 MHZ to 3 GHz. The objective is to specify the method for demonstration of compliance with the specific absorption rate (SAR) limits for such equipment.

Committee
CLC/TC 106X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Standards Relationship
NEN EN 50361 : 2001 Identical
I.S. EN 50361:2001 Identical
VDE 0848-361 : 2002 Identical
NF EN 50361 : 2001 Identical
SN EN 50361 : 2001 Identical
DIN EN 50361 : 2002 Identical
UNE-EN 50361:2003 Identical
NBN EN 50361 : 2002 Identical
CEI EN 50361 : 1ED 2001 Identical
BS EN 50361:2001 Identical

EN 50392:2004 Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz - 300 GHz)
01/208272 DC : DRAFT NOV 2001 EN 50CCC-1 - GENERIC STANDARD TO DEMONSTRATE THE COMPLIANCE OF ELECTRONIC AND ELECTRICAL APPARATUS WITH THE BASIC RESTRICTIONS RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)
I.S. EN 50392:2004 GENERIC STANDARD TO DEMONSTRATE THE COMPLIANCE OF ELECTRONIC AND ELECTRICAL APPARATUS WITH THE BASIC RESTRICTIONS RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)
BS EN 50392:2004 Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz - 300 GHz)
02/205824 DC : 0 PREN 50 XXX - BASIC STANDARD ON MEASUREMENT AND CALCULATION PROCEDURES FOR HUMAN EXPOSURE TO ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)
TS 137 544 : 14.5.0 UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM (UMTS); LTE; UNIVERSAL TERRESTRIAL RADIO ACCESS (UTRA) AND EVOLVED UTRA (E-UTRA); USER EQUIPMENT (UE) OVER THE AIR (OTA) PERFORMANCE; CONFORMANCE TESTING (3GPP TS 37.544 VERSION 14.5.0 RELEASE 14)
TR 125 914 : 13.0.0 UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM (UMTS); MEASUREMENTS OF RADIO PERFORMANCES FOR UMTS TERMINALS IN SPEECH MODE (3GPP TR 25.914 VERSION 14.0.0 RELEASE 14)
CEI 211-10 : 2002 GUIDANCE FOR CARRYING OUT A BASE RADIO STATION COMPLYING WITH LIMITS FOR HUMAN EXPOSURE TO HIGH FREQUENCY ELECTROMAGNETIC FIELDS
IEEE 1528-2013 REDLINE IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.