EN 50561-1:2013/AC:2015

Current
Current

The latest, up-to-date edition.

Power line communication apparatus used in low-voltage installations - Radio disturbance characteristics - Limits and methods of measurement - Part 1: Apparatus for in-home use
Published date

16-01-2015

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirement for conducted disturbances
   at AC mains power ports
5 Requirement for conducted disturbances
   at telecommunication/network ports
6 Requirements for conducted disturbances
   and communications signals at PLC ports
7 Requirement for radiated disturbances
8 Measurement conditions for PLC ports
9 Measurement methods and procedures for
   PLC ports
10 Measurement uncertainty
Annex A (normative) - Excluded frequency ranges
Annex B (normative) - Impedance Stabilisation
        Network (ISN) for asymmetric disturbance
        measurements
Annex C (informative) - Cognitive frequency exclusion
Annex ZZ (informative) - Coverage of Essential
         Requirements of EU Directives
Bibliography

Committee
TC 210
DevelopmentNote
Supersedes PREN 50561-1. (10/2013)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

EN 61850-3:2014 Communication networks and systems for power utility automation - Part 3: General requirements
EN 303 446-1 : 1.1.0 DRAFT ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 1: REQUIREMENTS FOR EQUIPMENT INTENDED TO BE USED IN RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRY LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU
17/30365901 DC : 0 BS EN 50160 AMD 2 - VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
BS EN 50561-3:2016 Power line communication apparatus used in low-voltage installations. Radio disturbance characteristics. Limits and methods of measurement Apparatus operating above 30 MHz
EN 303 446-2 : 1.1.0 DRAFT ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 2: SPECIFIC CONDITIONS FOR EQUIPMENT INTENDED TO BE USED IN INDUSTRIAL LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU
14/30281719 DC : 0 BS EN 50561-3 - POWERLINE COMMUNICATION APPARATUS USED IN LOW-VOLTAGE INSTALLATIONS - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT - PART 3: APPARATUS OPERATING ABOVE 30 MHZ
UNE-EN 50561-3:2016 Power line communication apparatus used in low-voltage installations - Radio disturbance characteristics - Limits and methods of measurement - Part 3: Apparatus operating above 30 MHz
PREN 50561-3 : DRAFT 2014 POWERLINE COMMUNICATION APPARATUS USED IN LOW-VOLTAGE INSTALLATIONS - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT - PART 3: APPARATUS OPERATING ABOVE 30 MHZ
I.S. EN 61850-3:2014 COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 3: GENERAL REQUIREMENTS
I.S. EN 50561-3:2016 POWER LINE COMMUNICATION APPARATUS USED IN LOW-VOLTAGE INSTALLATIONS - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT - PART 3: APPARATUS OPERATING ABOVE 30 MHZ
EN 50561-3:2016 Power line communication apparatus used in low-voltage installations - Radio disturbance characteristics - Limits and methods of measurement - Part 3: Apparatus operating above 30 MHz

CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
TS 102 578 : 1.2.1 POWERLINE TELECOMMUNICATIONS (PLT); COEXISTENCE BETWEEN PLT MODEMS AND SHORT WAVE RADIO BROADCASTING SERVICES
2004/108/EC : 2004 DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
EN 55022:2010/AC:2011 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008)
119999/5/EC : 1999 DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 1999 ON RADIO EQUIPMENT AND TELECOMMUNICATIONS TERMINAL EQUIPMENT AND THE MUTUAL RECOGNITION OF THEIR CONFORMITY
ES 201 980 : 4.1.1 DIGITAL RADIO MONDIALE (DRM); SYSTEM SPECIFICATION
EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.