• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 60432-1:2000/A2:2012

Current
Current

The latest, up-to-date edition.

INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 1 - TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES (IEC 60432-1:1999/A2:2011)
Amendment of

EN 60432-1:2000

Published date

04-05-2012

FOREWORD
1 General
2 Requirements
3 Assessment
Annex A (normative) - Miscellaneous test procedures
Annex B (normative) - Packaging marking symbols
Annex C (normative) - Resistance to torque test procedures
Annex D (normative) - Induced-failure test
Annex E (normative) - Operation-to-failure test
Annex F (normative) - Acceptance numbers for various sample
        sizes and AQLs
Annex G (normative) - Acceptance criteria - Continuously
        variable results
Annex H (normative) - Induced-failure test - Grouping, sampling
        and compliance
Annex J (normative) - Method of measuring mains impedance
Annex K (informative) - Information for luminaire design
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Defines the safety and interchangeability requirements of tungsten filament incandescent lamps for general lighting service having: - rated wattage up to and including 200 W; - rated voltage of 50 V to 250 V inclusive; - bulbs of the A, B, C, G, M, P, PS, PAR or R shapes, or other bulb shapes where the lamps are intended to serve the same purpose as lamps with the foregoing bulb shapes; - bulbs with all kinds of finishes; - caps B15d, B22d, E12, E14, E17, E26, E26d, E26/50x39, E27 or or E27/51x39

Committee
TC 34
DevelopmentNote
Supersedes EN 60432. (03/2004)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

17/30355026 DC : 0 BS EN 60081:1998/FPRA6:2015/PRAA:2017 - DOUBLE-CAPPED FLUORESCENT LAMPS - PERFORMANCE SPECIFICATIONS
CEI 34-1 : 2007 TUNGSTEN FILAMENT LAMPS FOR PARTICULAR APPLICATIONS
PREN 12665 : DRAFT 2009 LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS
BS EN 60064 : 1996 TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS
BS EN 50019:2000 Electrical apparatus for potentially explosive atmospheres. Increased safety \'e\'
BS EN 61231 : 2010 INTERNATIONAL LAMP CODING SYSTEM (ILCOS)
UNE-EN 60968:2015 Self-ballasted fluorescent lamps for general lighting services - Safety requirements
DIN EN 12665:2016-09 (Draft) LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS
EN IEC 60079-7:2015/A1:2018 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017)
EN 60968:2015 Self-ballasted fluorescent lamps for general lighting services - Safety requirements
EN 60064:1995/A5:2009 TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS
EN 62798:2014/AC:2014 INDUSTRIAL ELECTROHEATING EQUIPMENT - TEST METHODS FOR INFRARED EMITTERS (IEC 62798:2014)
BS EN 60630 : 1999 MAXIMUM LAMP OUTLINERS FOR INCANDESCENT LAMPS
09/30185891 DC : 0 BS EN 12665 - LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS
CEI 34-119 : 2010 GUIDE FOR LUMINAIRE DESIGN - INFORMATION FOR A SAFE AND CORRECT OPERATION OF THE LIGHT SOURCES
I.S. EN 60432-3:2013 INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 3: TUNGSTENHALOGEN LAMPS (NON-VEHICLE) (IEC 60432-3:2012 (EQV))
BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
I.S. EN 60630:2000 MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS
I.S. EN 60432-2:2004 INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 2: TUNGSTEN HALOGEN LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES (IEC 60432-2:1999 (MOD))
CEI EN 60432-3 : 2013 INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 3: TUNGSTEN-HALOGEN LAMPS (NON-VEHICLE)
BS EN 60432-3:2013 Incandescent lamps. Safety specifications Tungsten-halogen lamps (non-vehicle)
BS EN 60968:2015 Self-ballasted fluorescent lamps for general lighting services. Safety requirements
BS EN 62798:2014 Industrial electroheating equipment. Test methods for infrared emitters
I.S. EN 60064:1996 TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS
I.S. EN 60968:2015 SELF-BALLASTED FLUORESCENT LAMPS FOR GENERAL LIGHTING SERVICES - SAFETY REQUIREMENTS
EN 60598-1:2015/A1:2018 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
BS EN 60598-1:2015 Luminaires General requirements and tests
UNI EN 12665 : 2011 LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS
BS EN 60360:1999 Standard method of measurement of lamp cap temperature rise
I.S. EN 60598-1:2015 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
BS EN 60432-2 : 2000 INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 2: TUNGSTEN HALOGEN LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES
I.S. EN 60081:1998 DOUBLE-CAPPED FLUORESCENT LAMPS - PERFORMANCE SPECIFICATIONS
UNE-EN 60598-1:2015 Luminaires - Part 1: General requirements and tests
I.S. EN 61231:2010 INTERNATIONAL LAMP CODING SYSTEM (ILCOS) (IEC 61231:2010 (EQV))
EN 60081:1998/A11:2018 Double-capped fluorescent lamps - Performance specifications
UNE-EN 12665:2012 Light and lighting - Basic terms and criteria for specifying lighting requirements
BS EN 12665:2011 Light and lighting. Basic terms and criteria for specifying lighting requirements
UNE-EN 60064:1998 TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES. PERFORMANCE REQUIREMENTS.
UNE-EN 62560:2013 Self-ballasted LED-lamps for general lighting services by voltage > 50 V - Safety specifications
I.S. EN 62798:2014 INDUSTRIAL ELECTROHEATING EQUIPMENT - TEST METHODS FOR INFRARED EMITTERS
I.S. EN 60079-7:2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
BS EN 62560:2012+A11:2019 Self-ballasted LED-lamps for general lighting services by voltage > 50 V. Safety specifications
UNE-EN 60432-3:2013 Incandescent lamps - Safety specifications - Part 3: Tungsten-halogen lamps (non-vehicle)
UNE-EN 60079-7:2016 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
I.S. EN 12665:2011 LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS
I.S. EN 50019:2001 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
IEC 60630:2005 CSV Maximum lamp outlines for incandescent lamps
EN 60630:1998/A7:2015 MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS (IEC 60630:1994/A7:2014, MODIFIED)
EN 60432-2:2000/A2:2012 INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 2: TUNGSTEN HALOGEN LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES
EN 50019:2000/corrigendum Apr. 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
EN 61231:2010/A1:2013 INTERNATIONAL LAMP CODING SYSTEM (ILCOS) (IEC 61231:2010/A1:2013)
EN 60432-3:2013 Incandescent lamps - Safety specifications - Part 3: Tungsten-halogen lamps (non-vehicle)

IEC 60061-3:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
ISO 3951:1989 Sampling procedures and charts for inspection by variables for percent nonconforming
IEC TR 62471-2:2009 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety
IEC TR 60887:2010 Glass bulb designation system for lamps
EN 60432-2:2000/A2:2012 INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 2: TUNGSTEN HALOGEN LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES
IEC 60410:1973 Sampling plans and procedures for inspection by attributes
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements
EN 60360:1998 Standard method of measurement of lamp cap temperature rise
EN 60064:1995/A5:2009 TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
IEC 60061-1:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps
IEC 62471:2006 Photobiological safety of lamps and lamp systems
IEC 60432-2:1999+AMD1:2005+AMD2:2012 CSV Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes
EN 62471:2008 Photobiological safety of lamps and lamp systems
IEC 60360:1998 Standard method of measurement of lamp cap temperature rise

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.