Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 kV up to but not including 300 kV
Published date

09-12-1999

1 General
      1.1 Scope and object
      1.2 Normative references
      1.3 Definitions
      1.4 Values which characterize a post insulator of
             organic material
      1.5 Documentation
      1.6 Normal service conditions
2 General requirements for tests
      2.1 Classification of tests
      2.2 Quality assurance
      2.3 General requirements for electrical tests
      2.4 Lightning impulse voltage tests
      2.5 Power-frequency voltage tests
      2.6 Standard reference atmospheric conditions for
             tests
      2.7 Correction factors for atmospheric conditions
3 Type tests
      3.1 General
      3.2 General requirements for electrical type tests
      3.3 Dry lightning impulse withstand voltage test
      3.4 Dry power-frequency withstand voltage test
      3.5 Partial discharge extinction voltage test
      3.6 Lightning impulse puncture test
      3.7 Mechanical failing load test
      3.8 Test for deflection under load at normal
             ambient temperature
      3.9 Test for mechanical bending strength as a
             function of temperature
      3.10 Water absorption test
      3.11 Ageing and humidity test
      3.12 Flammability test
      3.13 Temperature cycle test
4 Sample tests
      4.1 General
      4.2 Verification of dimensions
      4.3 Re-test procedure
5 Routine tests
      5.1 General
      5.2 Visual examination
      5.3 Mechanical routine test
      5.4 Electrical routine test and partial discharge
             measurement
Annex A (informative) Tolerances of form and position
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications

Applicable to post insulators of organic material for indoor service in electrical installations or equipment operating in air at atmospheric pressure on alternating current with a nominal voltage greater than 1 000 V up, but not including, 300 kV, as defined by range I of EN 60071-1, and a frequency not greater than 100 Hz. Composite insulators are not covered by this standard. The object of this standard is - to define the terms used, - define electrical and mechanical characteristics of post insulators of organic material and to prescribe the conditions under which the specified values of these characteristics are verified, - to prescribe methods of testing, - to prescribe acceptance criteria. This standard does not give numerical values for insulator characteristics, nor does it deal with a choice of insulators for specific operating conditions. HD 578 S1 specifies numerical values for electrical and mechanical characteristics and gives the dimensions necessary for interchangeability of post insulators.

Committee
CLC/SR 36
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

Standards Relationship
NF EN 60660 : 2000 Identical
IEC 60660:1999 Identical
NBN EN 60660 : 2000 Identical
NEN EN IEC 60660 : 2000 Identical
I.S. EN 60660:2000 Identical
PN EN 60660 : 2002 Identical
SN EN 60660 : 1999 Identical
VDE 0441-3 : 2000-12 Identical
DIN EN 60660 : 2000 Identical
UNE-EN 60660:2001 Identical
BS EN 60660:2000 Identical
CEI EN 60660 : 2000 Identical

UNE-EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
BS EN 50119 : 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
BS EN 61869-1:2009 Instrument transformers General requirements
15/30298489 DC : 0 BS EN 50124-1 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
PREN 50119 : DRAFT 2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
PREN 50124-1 : DRAFT 2015 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
I.S. EN 50124-1:2017 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
I.S. EN 50119:2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
VDE 0674-1 : 2001-12 TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV
DIN EN 60168 : 2001-12 TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV
NF EN 50119 : 2010 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
UNE-EN 61869-1:2010 Instrument transformers -- Part 1: General requirements
EN 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements
17/30341013 DC : DRAFT AUG 2017 BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
BS EN 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements
I.S. EN 62689-1:2016 CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS
I.S. EN 50119:2020 Railway applications - Fixed installations - Electric traction overhead contact lines
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
BS EN 50124-1:2017 Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment
EN 61869-1:2009 Instrument transformers - Part 1: General requirements

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60373:1990 Mechanical coupler for measurements on bone vibrators
IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
ISO 9002:1994 Quality systems — Model for quality assurance in production, installation and servicing
IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
IEC 60587:2007 Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
ISO 9000-1:1994 Quality management and quality assurance standards — Part 1: Guidelines for selection and use

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.