• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 60811-2-1 : 98 AMD 1 2001

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS

Superseded date

01-06-2012

Published date

12-01-2013

Foreword
1 General
   1.1 Scope
   1.2 Normative references
2 Test values
3 Applicability
4 Type tests and other tests
5 Pre-conditioning
6 Test temperature
7 Median value
8 Ozone resistance test
   8.1 Test method
   8.2 Determination of ozone concentration
9 Hot set test
   9.1 Sampling and preparation of test pieces and
        determination of their cross-sectional area
   9.2 Test apparatus
   9.3 Procedure
   9.4 Evaluation of results
10 Mineral oil immersion test for sheaths
   10.1 Sampling and preparation of the test pieces
   10.2 Determination of the cross-sectional area of the
        test piece
   10.3 Oil to be used
   10.4 Procedure
   10.5 Determination of mechanical properties
   10.6 Expression of results
Annex ZA (normative) Normative references to international publications
         with their corresponding European publications

Gives test methods to be used for testing polymeric insulating and sheathing materials of electric and optical cables for power distribution and telecommunications, including cables used on ships and in offshore applications.

Committee
TC 20
DevelopmentNote
FORMER HD 505.2.1. (05/2001)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

HD 21.1 : 200S4 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - GENERAL REQUIREMENTS
08/30188836 DC : 0 BS EN 50525-3-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
BS EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables General introduction
I.S. EN 50396:2005 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
03/316743 DC : DRAFT OCT 2003 EN 50396 - NON ELECTRICAL TEST METHODS FOR ELECTRIC CABLES
BS EN 61230:2008 Live working. Portable equipment for earthing or earthing and short-circuiting
I.S. HD 605:2008 ELECTRIC CABLES - ADDITIONAL TEST METHODS
I.S. EN 50363-4-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 4-1: PVC SHEATHING COMPOUNDS
BS EN 50363-2-2:2005 Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric covering compounds
BS 7933-2:2007 Electric cables. Accessories. Material characterisation Fingerprinting and type tests for heat shrinkable components for low voltage applications
BS EN 50264-2-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables
BS EN 50363-9-1:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous insulating compounds. Cross-linked polyvinyl chloride (XLPVC)
CEI 20-95 : 2010 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS
CEI EN 50525-2-22 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
BS EN 50363-6 : 2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS
I.S. EN 50363-10-2:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 10-2: MISCELLANEOUS SHEATHING COMPOUNDS - THERMOPLASTIC POLYURETHANE
I.S. EN 61138:2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
I.S. EN 50264-3-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
I.S. HD 631.2:2007 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS
HD 631.2 : 2007 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS
BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
I.S. EN 50264-2-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
I.S. EN 50290-2-26:2002 COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS
I.S. EN 50363-7:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 7: HALOGEN-FREE, THERMOPLASTIC INSULATING COMPOUNDS
I.S. EN 50306-4:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLE STANDARD WALL SHEATHED
I.S. EN 50363-2-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS
EN 50290-2-26 : 2002 AMD 1 2007 COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS
EN 50363-2-1 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 61138:2007 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
EN 50363-10-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC)
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
EN 50363-9-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC)
EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 50363-6 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS
EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
HD 22-1 : 200S4 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOSETTING INSULATION - GENERAL REQUIREMENTS
EN 50363-7:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 7: Halogen-free, thermoplastic insulating compounds
EN 50264-2:2002 Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 2: Single core cables
UNE-EN 50264-3-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
BS EN 50382-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
05/30133180 DC : 0 EN 50382-1 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
CEI EN 50306-4 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLES STANDARD WALL SHEATHED
BS EN 50290-2-26:2002 Communication cables Common design rules and construction. Halogen free flame retardant insulation compounds
05/30137085 DC : 0 EN 50264-3-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
BS EN 50264-2-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables
I.S. EN 50264-2:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - STANDARD WALL - PART 2: SINGLE CORE CABLES
I.S. EN 50264-3-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
BS EN 50396 : 2005 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
I.S. EN 50363-3:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS
UNE-EN 50525-3-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
I.S. HD 22-1:2002 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 1: GENERAL REQUIREMENTS
I.S. EN 50363-5:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
EN 50306-1:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
BS EN 50363-10-2:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Thermoplastic polyurethane
I.S. HD 21-1:2002 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 1: GENERAL REQUIREMENTS
BS EN 50382-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
I.S. EN 50363-8:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS
BS EN 50525-3-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
CEI EN 50264-2-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
BS EN 50264-3-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables
BS EN 50306-2:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core cables
CEI EN 50306-2 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES
CEI EN 50264-2-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
05/30136253 DC : 0 EN 50264-2-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
UNE-EN 50264-2-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
I.S. EN 50382-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
I.S. EN 50363-10-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 10-1: MISCELLANEOUS SHEATHING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC)
BS EN 50264-2:2002 Railway applications. Railway rolling stock cables having special fire performance. Standard wall Single core cables
CEI EN 50264-3-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
I.S. EN 50363-6:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
UNE-EN 50264-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
CEI EN 50306-3 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED
BS EN 50264-3:2002 Railway applications. Railway rolling stock cables having special fire performance. Standard wall Multicore cables
BS EN 50525-2-22:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. High flexibility braided cables with crosslinked elastomeric insulation
BS EN 50363-1:2005 Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric insulating compounds
BS EN 50306-1:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall General requirements
UNE-EN 50264-3-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
BS EN 50363-4-1:2005 Insulating, sheathing and covering materials for low voltage energy cables PVC sheathing compounds
CEI EN 50306-1 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS
BS EN 50264-3-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables
BS EN 50363-4-2:2005 Insulating, sheathing and covering materials for low voltage energy cables PVC covering compounds
CEI EN 50264-3-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
08/30188788 DC : 0 BS EN 50525-2-22 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
05/30136249 DC : 0 EN 50264-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS EN 50306-4:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Multicore and multipair cables standard wall sheathed
05/30133183 DC : 0 EN 50382-2 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREE C
CEI EN 50264-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS EN 50363-10-1:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Cross-linked polyvinyl chloride (XLPVC)
BS EN 50363-7:2005 Insulating, sheathing and covering materials for low voltage energy cables Halogen-free, thermoplastic insulating compounds
I.S. EN 50525-3-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
PREN 50525-2-22 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CEI EN 50525-3-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50363-9-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 9-1: MISCELLANEOUS INSULATING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC)
I.S. EN 50363-4-2:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 4-2: PVC COVERING COMPOUNDS
I.S. EN 50363-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 1: CROSS-LINKED ELASTOMERIC INSULATING COMPOUNDS
BS EN 61138:1998 Cables for portable earthing and short-circuiting equipment
I.S. EN 50363-2-2:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-2: CROSS-LINKED ELASTOMERIC COVERING COMPOUNDS
I.S. EN 50382-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
I.S. EN 50306-2:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES
I.S. EN 60811-1-1:1997 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
I.S. EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
I.S. EN 50264-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
I.S. EN 50363-0:2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW-VOLTAGE ENERGY CABLES - PART 0: GENERAL INTRODUCTION
I.S. EN 50306-1:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS
EN 50306-2:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
EN 50306-3:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
EN 50306-4:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair cables standard wall sheathed
EN 50363-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds
EN 50363-3 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS
EN 50525-2-22:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation
I.S. EN 50525-2-22:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
05/30137088 DC : 0 EN 50264-3-2 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATON WITH REDUCED DIMENSIONS - MULTICORE CABLES
BS EN 50264-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance General requirements
UNE-EN 50525-2-22:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation
BS EN 50306-3:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
UNE-EN 50264-2-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
UNE-EN 61230:2011 Live working - Portable equipment for earthing or earthing and short-circuiting
I.S. EN 50264-2-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
I.S. EN 50264-3:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - STANDARD WALL - PART 3: MULTICORE CABLES
PREN 50525-3-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
UNE-EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables -- Part 0: General introduction
CEI EN 50290-2-26 : 2008 COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS
I.S. EN 50306-3:2002 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED
EN 50363-4-2:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 4-2: PVC covering compounds
EN 50363-2-2:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 2-2: Cross-linked elastomeric covering compounds
EN 50363-10-2 : 2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 10-2: Miscellaneous sheathing compounds - Thermoplastic polyurethane
EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction
EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
EN 50264-3-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
EN 50382-2:2008/A1:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
EN 50363-5 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
EN 50396 : 2005 AMD 1 2011 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
EN 50264-3:2002 Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 3: Multicore cables
EN 50363-4-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds
EN 50525-3-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE

IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
ISO 1817:2015 Rubber, vulcanized or thermoplastic Determination of the effect of liquids

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.