EN 61131-6:2012

Current
Current

The latest, up-to-date edition.

Programmable controllers - Part 6: Functional safety
Published date

30-11-2012

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Conformance to this standard
5 FS-PLC safety lifecycle
6 FS-PLC design requirements specification
7 FS-PLC design, development and validation plan
8 FS-PLC architecture
9 HW design, development and validation planning
10 FS-PLC SW design and development
11 FS-PLC safety validation
12 FS-PLC type tests
13 FS-PLC verification
14 Functional safety assessment
15 FS-PLC operation, maintenance and modification
   procedures
16 Information to be provided by the FS-PLC
   manufacturer for the user
Annex A (informative) - Reliability calculations
Annex B (informative) - Typical FS-PLC Architectures
Annex C (informative) - Energise to trip applications
        of FS-PLC
Annex D (informative) - Available failure rate databases
Annex E (informative) - Methodology for the estimation
        of common cause failure rates in a multiple channel
        FS-PLC
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

IEC 61131-6:2012 specifies requirements for programmable controllers (PLCs) and their associated peripherals, as defined in Part 1, which are intended to be used as the logic subsystem of an electrical/electronic/programmable electronic (E/E/PE) safety-related system. A programmable controller and its associated peripherals complying with the requirements of this part is considered suitable for use in an E/E/PE safety-related system and is identified as a functional safety programmable logic controller (FS-PLC). An FS-PLC is generally a hardware (HW) / software (SW) subsystem. An FS-PLC may also include software elements, for example predefined function blocks.

Committee
CLC/TC 65X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

08/30195618 DC : 0 BS EN 50325-5 - INDUSTRIAL COMMUNICATIONS SUBSYSTEM BASED ON ISO 11898 (CAN) FOR CONTROLLER-DEVICE INTERFACES - PART 5: FUNCTIONAL SAFETY COMMUNICATION BASED ON EN 50325-4
I.S. EN 50325-5:2010 INDUSTRIAL COMMUNICATIONS SUBSYSTEM BASED ON ISO 11898 (CAN) FOR CONTROLLER-DEVICE INTERFACES - PART 5: FUNCTIONAL SAFETY COMMUNICATION BASED ON EN 50325-4
PREN 50325-5 : DRAFT 2008 INDUSTRIAL COMMUNICATIONS SUBSYSTEM BASED ON ISO 11898 (CAN) FOR CONTROLLER-DEVICE INTERFACES - PART 5: FUNCTIONAL SAFETY COMMUNICATION BASED ON EN 50325-4
BS EN 50325-5:2010 Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces Functional safety communication based on EN 50325-4
CEI EN 50325-5 : 2012 INDUSTRIAL COMMUNICATIONS SUBSYSTEM BASED ON ISO 11898 (CAN) FOR CONTROLLER-DEVICE INTERFACES - PART 5: FUNCTIONAL SAFETY COMMUNICATION BASED ON EN 50325-4
EN 50325-5:2010 Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 5: Functional safety communication based on EN 50325-4

IEC 61025:2006 Fault tree analysis (FTA)
IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
EN 61508-6:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3
ISO/IEC 2382-1:1993 Information technology Vocabulary Part 1: Fundamental terms
EN 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements
EN 61326-3-2:2008 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment
IEC 61326-3-2:2017 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment
EN 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEEE 828-2012 IEEE Standard for Configuration Management in Systems and Software Engineering
EN 61784-3:2016/A1:2017 INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3: FUNCTIONAL SAFETY FIELDBUSES - GENERAL RULES AND PROFILE DEFINITIONS (IEC 61784-3:2016/A1:2017)
EN 50205:2002 Relays with forcibly guided (mechanically linked) contacts
IEC 61131-3:2013 Programmable controllers - Part 3: Programming languages
IEC 61511-1:2016+AMD1:2017 CSV Functional safety - Safety instrumented systems for the process industry sector - Part 1: Framework, definitions, system, hardware and application programming requirements
IEC 61131-1:2003 Programmable controllers - Part 1: General information
EN 61131-2:2007 Programmable controllers - Part 2: Equipment requirements and tests
EN 61131-1:2003 Programmable controllers - Part 1: General information
IEC 61326-3-2 : 2.0 ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - EMC REQUIREMENTS - PART 3-2: IMMUNITY REQUIREMENTS FOR SAFETY-RELATED SYSTEMS AND FOR EQUIPMENT INTENDED TO PERFORM SAFETY-RELATED FUNCTIONS (FUNCTIONAL SAFETY) - INDUSTRIAL APPLICATIONS WITH SPECIFIED ELECTROMAGNETIC ENVIRONMENT
IEC TR 61131-4:2004 Programmable controllers - Part 4: User guidelines
IEC 61326-3-1 : 2.0 ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - EMC REQUIREMENTS - PART 3-1: IMMUNITY REQUIREMENTS FOR SAFETY-RELATED SYSTEMS AND FOR EQUIPMENT INTENDED TO PERFORM SAFETY-RELATED FUNCTIONS (FUNCTIONAL SAFETY) - GENERAL INDUSTRIAL APPLICATIONS
IEC TS 61000-1-2:2008 Electromagnetic compatibility (EMC) - Part 1-2: General - Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena
IEC 61508-5:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508)
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 60947-5-1 : 4.0 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-1: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTROMECHANICAL CONTROL CIRCUIT DEVICES
IEC 61078:2016 Reliability block diagrams
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61165:2006 Application of Markov techniques
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61508-4:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508)
IEC 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508)
ISO 8402:1994 Quality management and quality assurance — Vocabulary
IEC TR 62380:2004 Reliability data handbook - Universal model for reliability prediction of electronics components, PCBs and equipment
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 61508-2:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems
ISO/IEC Guide 51:2014 Safety aspects Guidelines for their inclusion in standards
IEC 60300-3-2:2004 Dependability management - Part 3-2: Application guide - Collection of dependability data from the field
IEC 61511-3:2016 Functional safety - Safety instrumented systems for the process industry sector - Part 3: Guidance for the determination of the required safety integrity levels
IEC 61496-3:2008 Safety of machinery - Electro-sensitive protective equipment - Part 3: Particular requirements for Active Opto-electronic Protective Devices responsive to Diffuse Reflection (AOPDDR)
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
ISO/IEC 12207:2008 Systems and software engineering Software life cycle processes
IEC 61069-7:2016 Industrial-process measurement, control and automation - Evaluation of system properties for the purpose of system assessment - Part 7: Assessment of system safety
IEC GUIDE 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
ISO 13849-2:2012 Safety of machinery — Safety-related parts of control systems — Part 2: Validation
IEC 61511-2:2016 Functional safety - Safety instrumented systems for the process industry sector - Part 2: Guidelines for the application of IEC 61511-1:2016
IEC 62079:2001 Preparation of instructions - Structuring, content and presentation
IEC 61496-1:2012 Safety of machinery - Electro-sensitive protective equipment - Part 1: General requirements and tests
ISO 9001:2015 Quality management systems — Requirements
IEC 61506:1997 Industrial-process measurement and control - Documentation ofapplication software
IEC 61131-2:2017 Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
ISO/IEC 2382-14:1997 Information technology Vocabulary Part 14: Reliability, maintainability and availability
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 61508-6:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508)
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
IEC 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508)
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems
IEC 61508-7:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508)
IEEE 352-1987 IEEE Guide for General Principles of Reliability Analysis of Nuclear Power Generating Station Safety Systems
EN 61326-3-1:2017 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - General industrial applications
ISO 13849-1:2015 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design
IEC 61508-2:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508)
ISO 14224:2016 Petroleum, petrochemical and natural gas industries Collection and exchange of reliability and maintenance data for equipment
IEC 61326-3-1:2017 Electrical equipment for measurement, control and laboratory use - EMC requirements – Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) – General industrial applications
ISO 9000-3:1997 Quality management and quality assurance standards Part 3: Guidelines for the application of ISO 9001:1994 to the development, supply, installation and maintenance of computer software
IEC 61784-3:2016+AMD1:2017 CSV Industrial communication networks - Profiles - Part 3: Functional safety fieldbuses - General rules and profile definitions
ISA TR84.00.02-1 : 2002 SAFETY INSTRUMENTED FUNCTIONS (SIF) - SAFETY INTEGRITY LEVEL (SIL) EVALUATION TECHNIQUES - PART 1: INTRODUCTION

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.