EN 61347-2-10:2001/corrigendum:2010

Current

Current

The latest, up-to-date edition.

LAMP CONTROLGEAR - PART 2-10: PARTICULAR REQUIREMENTS FOR ELECTRONIC INVERTORS AND CONVERTORS FOR HIGH-FREQUENCY OPERATION OF COLD TUBULAR DISCHARGE LAMPS (NEON TUBES) (IEC 61347-2-10:2000/A1:2008)

Published date

03-12-2010

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Terminals
9 Provisions for earthing
10 Protection against accidental contact with live parts
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Normal conditions
15 Abnormal conditions
16 Fault conditions
17 Construction
18 Creepage distances and clearances
19 Protective circuits
20 Screws, current-carrying parts and connections
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
23 No-load rated output voltage and rated output current
Annex A (normative) - Test to establish whether
        a conductive part is a live part which may cause
        an electric shock
Annex B (normative) - Particular requirements for
        thermally protected lamp controlgear
Annex C (normative) - Particular requirements for
        electronic lamp controlgear with means of protection
        against overheating
Annex D (normative) - Requirements for carrying
        out the heating tests of thermally protected
        lamp controlgear
Annex E (normative) - Use of constant S other than
        4500 in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation
        of the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Measurement of currents and
        voltages in the output circuits of electronic invertors
        or convertors for neon tubes
Annex ZA (normative) - Normative references to
         international publications with their corresponding
         European publications

This part of EN 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.

Committee
TC 34
DevelopmentNote
To be read in conjunction with EN 61347-1. (05/2010)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

I.S. EN 50107-1:2002:INC:AMD1:2004 SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 KV BUT NOT EXCEEDING 10 KV - PART 1: GENERAL REQUIREMENTS
BS EN 50107-1:2002 Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV General requirements
16/30342256 DC : 0 BS EN 50107-3 - PRODUCT STANDARD COVERING LUMINOUS SIGNS WITH DISCHARGE LAMPS AND/OR LED (LIGHT EMITTING DIODES) AND/OR EL (ELECTROLUMINESCENT) LIGHTSOURCES WITH A NOMINAL VOLTAGE NOT EXCEEDING 1000 V, WITH THE EXCLUSION OF GENERAL LIGHTING, TRAFFIC- OR EMERGENCY RELATED PURPOSE
PREN 50107-3 : DRAFT 2016 PRODUCT STANDARD COVERING LUMINOUS SIGNS WITH DISCHARGE LAMPS AND/OR LED (LIGHT EMITTING DIODES) AND/OR EL (ELECTROLUMINESCENT) LIGHTSOURCES WITH A NOMINAL VOLTAGE NOT EXCEEDING 1000 V, WITH THE EXCLUSION OF GENERAL LIGHTING, TRAFFIC- OR EMERGENCY RELATED PURPOSE
CEI EN 60598-2-14 : 2010 LUMINAIRES - PART 2-14: PARTICULAR REQUIREMENTS - LUMINAIRES FOR COLD CATHODE TUBULAR - DISCHARGE LAMPS (NEON TUBES) AND SIMILAR EQUIPMENT
01/206090 DC : DRAFT OCT 2001 EN 50107-2 - SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 KV BUT NOT EXCEEDING 10 KV - PART 2: REQUIREMENTS FOR EARTH-LEAKAGE AND OPEN-CIRCUIT PROTECTIVE DEVICES
BS EN 60598-2-14:2009 Luminaires Particular requirements. Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment
I.S. EN 50107-1:2002 SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 KV BUT NOT EXCEEDING 10 KV - PART 1: GENERAL REQUIREMENTS
EN 60598-2-14:2009 Luminaires - Part 2-14: Particular requirements - Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment
EN 50107-1 : 2002 AMD 1 2004 SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 KV BUT NOT EXCEEDING 10 KV - PART 1: GENERAL REQUIREMENTS

IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
ISO 3864:1984 Safety colours and safety signs

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.