Components for low-voltage surge protective devices - Part 311: Performance requirements and test circuits for gas discharge tubes (GDT)

Superseded date

07-02-2022

Published date

09-08-2013

FOREWORD
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Service conditions
5 Mechanical requirements and materials
6 General
7 Electrical requirements
8 Test and measurement procedures and circuits
Annex ZA (normative) - Normative references to international
         Publications with their corresponding
         European publications
Bibliography

IEC 61643-311:2013 is applicable to gas discharge tubes (GDT) used for overvoltage protection in telecommunications, signalling and low-voltage power distribution networks with nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c..They are defined as a gap, or several gaps with two or three metal electrodes hermetically sealed so that gas mixture and pressure are under control. They are designed to protect apparatus or personnel, or both, from high transient voltages. This standard contains a series of test criteria, test methods and test circuits for determining the electrical characteristics of GDTs having two or three electrodes. This standard does not specify requirements applicable to complete surge protective devices, nor does it specify total requirements for GDTs employed within electronic devices, where precise coordination between GDT performance and surge protective device withstand capability is highly critical. This second edition of IEC 61643-311 cancels and replaces the first edition published in 2001. It constitutes a technical revision. Specific changes with respect to the previous edition are: Addition of performance values. Key words: gas discharge tubes (GDT), overvoltage protection in telecommunications, signalling and low-voltage power distribution networks, nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c.

Committee
CLC/SR 37B
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

BS EN 61643-312:2013 Components for low-voltage surge protective devices Selection and application principles for gas discharge tubes
BS EN 50526-2:2014 Railway applications. Fixed installations. D.C. surge arresters and voltage limiting devices Voltage limiting devices
I.S. CLC TS 61643-22:2006 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 22: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - SELECTION AND APPLICATION PRINCIPLES
05/30134962 DC : DRAFT JUN 2005 CENELEC TS 61643-22 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 22: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - SELECTION AND APPLICATION PRINCIPLES
DD CLC/TS 61643-22:2006 Low-voltage surge protective devices Surge protective devices connected to telecommunications and signalling networks. Selection and application principles
I.S. EN 62368-1:2014 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED)
I.S. EN 61643-312:2013 COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 312: SELECTION AND APPLICATION PRINCIPLES FOR GAS DISCHARGE TUBES (IEC 61643-312:2013 (EQV) + CORRIGENDUM JUL. 2013 (EQV))
EN 62368-1:2014/AC:2017-03 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED)
UNE-EN 50526-2:2014 Railway applications - Fixed installations - D.C. surge arresters and voltage limiting devices - Part 2: Voltage limiting devices
I.S. EN 50526-2:2014 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SURGE ARRESTERS AND VOLTAGE LIMITING DEVICES - PART 2: VOLTAGE LIMITING DEVICES
CEI EN 50526-2 : 2014 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SURGE ARRESTERS AND VOLTAGE LIMITING DEVICES - PART 2: VOLTAGE LIMITING DEVICES
EN 50526-2:2014 Railway applications - Fixed installations - D.C. surge arresters and voltage limiting devices - Part 2: Voltage limiting devices

IEC 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
EN 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
IEEE C62.31-2006 IEEE Standard Test Methods for Low-Voltage Gas-Tube Surge-Protective Device Components
IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
DIN VDE 0845-1 : 1987 PROTECTION OF TELECOMMUNICATION SYSTEMS AGAINST LIGHTNING, ELECTROSTATIC DISCHARGES AND OVER-VOLTAGES FROM ELECTRIC POWER INSTALLATIONS; PROVISIONS AGAINST OVER-VOLTAGES
EN 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
IEC 61643-11:2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 61180-1:1992 High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.