• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN ISO 8253-3:2012

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Acoustics - Audiometric test methods - Part 3: Speech audiometry (ISO 8253-3:2012)
Superseded date

19-02-2022

Published date

01-03-2012

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements for recording of speech material
5 Validation of speech material recordings
6 Requirements for speech audiometry
7 Ambient sound pressure levels in test room for
   speech audiometry
8 Sound field speech audiometry
9 Preparation and instruction of test subject
10 Subject's response mode
11 Determination of speech detection threshold level
12 Determination of speech recognition threshold level
13 Determination of speech recognition scores
14 Contralateral masking
15 Speech audiometry with competing sound
16 Format of speech audiogram
17 Measurement uncertainty
18 Maintenance and calibration of equipment
Annex A (informative) - Example of speech materials
Annex B (informative) - Examples of competing sound
        conditions
Annex C (informative) - Typical results
Annex D (informative) - Optimization of perceptual balance
        of test lists
Annex E (informative) - Measurement uncertainty
Bibliography

ISO 8253-3:2012 specifies basic methods for speech recognition tests for audiological applications.In order to ensure minimum requirements of precision and comparability between different test procedures including speech recognition tests in different languages, ISO 8253-3:2012 specifies requirements for the composition, validation and evaluation of speech test materials, and the realization of speech recognition tests. ISO 8253-3:2012 does not specify the contents of the speech material because of the variety of languages.Furthermore, ISO 8253-3:2012 also specifies the determination of reference values and fulfilment requirements for the realization and manner of presentation.ISO 8253-3:2012 specifies procedures and requirements for speech audiometry with the recorded test material being presented by air conduction through an earphone, or from a loudspeaker for sound field audiometry. Methods for using noise either for masking the non-test ear or as a competing sound are described.Some test subjects, for example children, can require amended test procedures not specified in ISO 8253-3:2012.Specialized tests such as those used for evaluating directional hearing and dichotic hearing are outside the scope of ISO 8253-3:2012.

Committee
CEN/TC 211
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

09/30198066 DC : 0 BS EN 15927 - SERVICES OFFERED BY HEARING AID PROFESSIONALS
NF EN 15927 : 2010 SERVICES OFFERED BY HEARING AID PROFESSIONALS
I.S. EN 15927:2010 SERVICES OFFERED BY HEARING AID PROFESSIONALS
UNI EN 15927 : 2010 SERVICES OFFERED BY HEARING AID PROFESSIONALS
EN 15927:2010 Services offered by hearing aid professionals
UNE-EN 15927:2011 Services offered by hearing aid professionals
CEI EN 60645-1 : 2016 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AUDIOMETRY
BS EN 60645-1:2017 Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry
BS EN 15927:2010 Services offered by hearing aid professionals
I.S. EN 60645-1:2017 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY
UNE-EN 60645-1:2015 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry
EN 60645-1:2017 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry

ISO 389-4:1994 Acoustics Reference zero for the calibration of audiometric equipment Part 4: Reference levels for narrow-band masking noise
IEC 60318-3:2014 Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry
ISO/TR 25417:2007 Acoustics Definitions of basic quantities and terms
ISO 266:1997 Acoustics — Preferred frequencies
IEC 60645-1:2017 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry
IEC 60050-801:1994 International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics
ISO 389-1:1998 Acoustics Reference zero for the calibration of audiometric equipment Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones
ISO 8253-1:2010 Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry
IEC 61260:1995 Electroacoustics - Octave-band and fractional-octave-band filters
IEC 60645-2:1993 Audiometers - Part 2: Equipment for speech audiometry
IEC 60318-1:2009 Electroacoustics - Simulators of human head and ear - Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones
ISO 8253-2:2009 Acoustics Audiometric test methods Part 2: Sound field audiometry with pure-tone and narrow-band test signals
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.