MEASUREMENT OF FLUID FLOW IN CLOSED CONDUITS - METHODS OF EVALUATING THE PERFORMANCE OF ELECTROMAGNETIC FLOW-METERS FOR LIQUIDS

Available format(s)

Hardcopy , PDF

Withdrawn date

30-04-2020

Language(s)

English

Published date

01-01-1994

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

Committees responsible
National foreword
Methods
Introduction
1 Scope
2 Normative references
3 Definitions
4 General testing procedure
5 Evaluation of the effect of an influence quantity
6 Tests for the evaluation of the effects of other
    influence quantities
Figures
1 Sample calibration showing distribution of test
    points
2 Typical circuit arrangements for upstream gate valve
    tests
3 Examples showing the effects of an upstream gate
    valve on three electromagnetic meters of DN 500
    (based on real data)
4 Annular or segmental obstructions used to determine
    the effects of a disturbance in the inlet flow on
    the response of the flow-meter
5 General test circuit
6 Test of the effect of a) mains frequency common-mode
    voltage (voltage applied between the earth of the
    primary and secondary devices) and b) mains
    frequency voltage between neutral and primary earth
    (voltage applied between earth and mains, if
    practicable)
7 Test of the effect of mains frequency voltage
    between earth and output terminals
8 Test of the effect of a.c. currents on earthed
    connection between primary and secondary devices
9 Test of the effect of series-mode signals at the
    supply frequency
10 Test of the effect of stray currents within the
    liquid
Annex
A Bibliography

Recommends methods of test for the evaluation of the performance of electromagnetic flow-meters for liquids flowing in closed conduits.

DocumentType
Standard
Pages
32
PublisherName
National Standards Authority of Ireland
Status
Withdrawn
SupersededBy

Standards Relationship
NF EN 29104 : 1993 Identical
UNE-EN 29104:1996 Identical
BS EN 29104:1993 Identical
SN EN 29104 : 1994 Identical
UNI EN 29104 : 1994 Identical
EN 29104 : 1993 Identical
ISO 9104:1991 Identical
NBN EN 29104 : 1993 Identical
DIN EN 29104:1993-08 Identical

View more information
£48.50
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.