• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

I.S. EN 60099-5:2013

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS (IEC 60099-5:2013 (EQV))
Available format(s)

Hardcopy , PDF

Withdrawn date

23-02-2021

Language(s)

English

Published date

01-01-2013

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General principles for the application of surge
  arresters
5 Surge arrester fundamentals and applications issues
6 Insulation coordination and surge arrester
  applications
7 Surge arresters for special applications
8 Asset management of surge arresters
Annex A (informative) - Determination of temporary
        overvoltages due to earth faults
Annex B (informative) - Current practice
Annex C (informative) - Arrester modelling techniques
        for studies involving insulation coordination
        and energy requirements
Annex D (informative) - Diagnostic indicators of
        metal-oxide surge arresters in service
Annex E (informative) - Typical data needed from arrester
        manufacturers for proper selection of surge
        arresters
Annex F (informative) - Typical maximum residual
        voltages for metal-oxide arresters without gaps
        according to IEC 60099-4
Annex G (informative) - Steepness reduction of
        incoming surge with additional line terminal
        surge capacitance
Annex H (informative) - End of life and replacement
        of old gapped SiC-arresters
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Gives information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
151
PublisherName
National Standards Authority of Ireland
Status
Withdrawn

Standards Relationship
UNE-EN 60099-5:2000 Identical
NBN EN 60099-5 : 2013 Identical
BS EN 60099-5:2013 Identical
NF EN 60099-5 : 2017 Identical
DIN EN 60099-5 : 2014 Identical
EN 60099-5:2013 Identical
SN EN 60099-5 : 1996 AMD 1 1999 Identical

IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC TR 60071-4:2004 Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks
IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC TR 62271-300:2006 High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC 60099-6:2002 Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less
EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 60099-8:2017 Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
EN 60071-2:1997 Insulation co-ordination - Part 2: Application guide
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
IEC TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems

View more information
£155.58
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.