• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

I.S. EN 61439-4:2013

Current
Current

The latest, up-to-date edition.

LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR CONSTRUCTION SITES (ACS) (IEC 61439-4:2012 (EQV))
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2013

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Interface characteristics
6 Information
7 Service conditions
8 Constructional requirements
9 Performance requirements
10 Design verification
11 Routine verification
101 Particular features of ACS
Annexes
Annex C (informative) - User information template
Annex D (informative) - Design verification
Annex O (informative) - Guidance on temperature rise
        verification
Annex P (normative) - Verification of the short-circuit
        withstand strength of busbar structures by
        comparison with a tested reference design by
        calculation
Annex AA (informative) - List of notes concerning
         certain countries
Annex BB (Void)
Annex CC (informative) - Items subject to agreement
         between the ASSEMBLY manufacturer and the
         user
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZB (normative) - Special national conditions
Annex ZZ (informative) - Coverage of Essential
         Requirements of EU Directive 2004/108/EC

Describes the specific requirements of ACS as follows: - ASSEMBLIES for which the rated voltage does not exceed 1000 V in case of a.c. or 1500 V in case of d.c.; - ASSEMBLIES where the nominal primary voltage and the nominal secondary voltage of transformers incorporated in ACS are within the limits specified above; - ASSEMBLIES intended for use on construction sites, both indoors and outdoors, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out; - transportable (semi-fixed) or mobile ASSEMBLIES with enclosure.

DevelopmentNote
Supersedes I.S. EN 60439-4. (04/2013) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
37
PublisherName
National Standards Authority of Ireland
Status
Current
Supersedes

Standards Relationship
EN 61439-4:2013 Identical

IEC TR 61439-0:2013 Low-voltage switchgear and controlgear assemblies - Part 0: Guidance to specifying assemblies
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control
IEC 61558-2-23:2010 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-23: Particular requirements and tests for transformers and power supply units for construction sites
IEC TR 61200-704:1996 Electrical installation guide - Part 704: Construction and demolition site installations
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60364-7-704:2017 Low-voltage electrical installations - Part 7-704: Requirements for special installations or locations - Construction and demolition site installations
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
EN 61558-2-23:2010 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-23: Particular requirements and tests for transformers and power supply units for construction sites
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements
IEC 60309-2:1999+AMD1:2005+AMD2:2012 CSV Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories

View more information
£48.50
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.