I.S. EN 62585:2012

Current
Current

The latest, up-to-date edition.

ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER (IEC 62585:2012 (EQV))
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2012

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Reference environmental conditions
5 Uncertainties of measurement
6 General requirements for measurement of
   adjustment value and corrections
7 Submission and inspection
8 Determination of the adjustment value at
   the calibration check frequency
9 Determination of corrections for the typical
   effects of reflections from the case of the sound
   level meter and diffraction of sound around the
   microphone
10 Determination of corrections for the deviation
   of the microphone free-field frequency response
   from a uniform frequency response
11 Determination of corrections for the use of
   windscreens and similar accessories
12 Determination of corrections over a range of
   frequencies when a sound calibrator is recommended
   for use by the sound level meter manufacturer
13 Determination of corrections over a range of
   frequencies when a comparison coupler is
   recommended for use by the sound level meter
   manufacturer
14 Determination of corrections over a range of
   frequencies when an electrostatic actuator is
   recommended for use by the sound level meter
   manufacturer
15 Documentation
Annex A (normative) - Calibration check frequency
        - Determination of the adjustment value
Annex B (normative) - Determination of the effects
        of reflections from the case of the sound level
        meter and diffraction of sound around the
        microphone
Annex C (normative) - Determination of the effects
        of the use of windscreens and similar accessories
Annex D (informative) - Determination of corrections
        for use with sound calibrators to determine
        equivalent free-field response at all frequencies
        of interest
Annex E (informative) - Determination of corrections
        for use with comparison couplers to determine
        equivalent free-field frequency response at all
        frequencies of interest
Annex F (informative) - Determination of corrections
        for use with electrostatic actuators to determine
        equivalent free-field frequency response at all
        frequencies of interest
Annex G (informative) - Comparison techniques
Annex H (informative) - Exact one-twelfth-octave
        frequencies
Annex I (informative) - Example calculations of
        expanded uncertainty of measurement
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Gives information on the corrections required over a range of frequencies in order for a periodic test of a sound level meter to be performed according to IEC 61672-3.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
46
PublisherName
National Standards Authority of Ireland
Status
Current

Standards Relationship
EN 62585 : 2012 Identical

IEC 61672-2:2013+AMD1:2017 CSV Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests
IEC 61094-5:2016 Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison
IEC 61183:1994 Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters
IEC TS 61094-7:2006 Measurement microphones - Part 7: Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones
IEC 60942:2003 Electroacoustics - Sound calibrators
IEC 61094-1:2000 Measurement microphones - Part 1: Specifications for laboratory standard microphones
IEC 61094-3:2016 Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
IEC 61094-8:2012 Measurement microphones - Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison
IEC 61094-2:2009 Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique
IEC 61672-3:2013 Electroacoustics - Sound level meters - Part 3: Periodic tests
IEC 61094-6:2004 Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response
IEC 61260:1995 Electroacoustics - Octave-band and fractional-octave-band filters
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

View more information
£58.57
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.