We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
  • IEC 60068-2-42:2003

    Current The latest, up-to-date edition.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist.
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You need to be logged in to add this standard to your Watchlist.
    Please log in now or create an account to add.
    You already added this Product in the Watchlist.

    Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French, Spanish, Castilian

    Published date:  22-05-2003

    Publisher:  International Electrotechnical Committee

    Add to Watchlist

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope and object
    2 Normative references
    3 Test apparatus
    4 Test atmosphere
    5 Preconditioning
    6 Method
    7 Details to be specified
    Annex A (informative) Generation of the test atmosphere by
                          direct mixing of sulphur dioxide with
                          air
    Bibliography

    Abstract - (Show below) - (Hide below)

    Provides accelerated means to assess the corrosive effects of atmospheres polluted with sulphur dioxide on contacts and connections.

    General Product Information - (Show below) - (Hide below)

    Committee TC 48/SC 48B
    Development Note Stability date: 2020. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
    UNE-EN 54-22:2016 Fire detection and fire alarm system - Part 22 : Resettable line-type heat detectors
    DIN EN 54-23:2010-06 Fire detection and fire alarm systems - Part 23: Fire alarm devices - Visual alarm devices
    09/30196772 DC : 0 BS ISO 7240-24 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 24: SOUND-SYSTEM LOUDSPEAKERS
    03/106844 DC : DRAFT MAY 2003 ISO 7240-11 - FIRE DETECTION AND ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
    BS ISO 9022-20:2015 Optics and photonics. Environmental test methods Humid atmosphere containing sulfur dioxide or hydrogen sulfide
    BS EN 54-28:2016 FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NONRESETTABLE LINE-TYPE HEAT DETECTORS
    14/30295302 DC : 0 BS EN 61587-1 ED. 4.0 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITIONS
    13/30280627 DC : 0 BS ISO 7240-15 - FIRE DETECTION AND ALARM SYSTEMS - PART 15: POINT-TYPE FIRE DETECTORS USING SMOKE AND HEAT SENSORS
    BS EN 54-31 : 2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS
    10/30210160 DC : 0 BS ISO 12239 - SMOKE ALARMS
    EN 54-5:2017 Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
    PD CEN ISO/TS 14907-1:2015 Electronic fee collection. Test procedures for user and fixed equipment Description of test procedures
    BS EN 61757-1:2012 (published 2012-08) Fibre optic sensors Generic specification
    DIN EN 54-25 E : 2009 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
    ISO 7240-5:2012 Fire detection and alarm systems Part 5: Point-type heat detectors
    03/106843 DC : DRAFT MAY 2003 ISO 7240-6 - FIRE DETECTION AND ALARM SYSTEMS - PART 6: POINT-TYPE FIRE DETECTORS FOR DETECTION OF CARBON MONOXIDE
    PREN 54-11 : DRAFT 2013 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
    BS EN 61439-4:2013 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR CONSTRUCTION SITES (ACS)
    PREN 54-20 : DRAFT 2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
    PREN 14604 : DRAFT 2016 SMOKE ALARM DEVICES
    04/30112662 DC : DRAFT APR 2004 IEC 61810-7 ED.2 - ELECTROMECHANICAL ELEMENTARY RELAYS - PART 7: TEST AND MEASUREMENT PROCEDURES
    BS EN 61300-2-28:2013 Fibre optic interconnecting devices and passive components. Basic test and measurement procedures Tests. Corrosive atmosphere (sulphur dioxide)
    17/30347208 DC : 0 BS ISO 7240-7 - FIRE DETECTION AND ALARM SYSTEMS - PART 7: POINT-TYPE SMOKE DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    05/30135750 DC : DRAFT JUL 2005 ISO 7240-10 - FIRE DETECTION AND ALARM SYSTEMS - PART 10: POINT-TYPE FLAME DETECTORS
    PREN 54-10 : DRAFT 2012 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
    10/30218875 DC : 0 BS EN 50130-5:2010 - ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
    DD CEN ISO/TS 14907-1:2010 Electronic fee collection. Test procedures for user and fixed equipment Description of test procedures
    BS ISO 7240-8:2014 FIRE DETECTION AND ALARM SYSTEMS - PART 8: POINT-TYPE FIRE DETECTORS USING A CARBON MONOXIDE SENSOR IN COMBINATION WITH A HEAT SENSOR
    09/30184483 DC : 0 BS EN 54-3 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
    16/30349531 DC : 0 BS ISO 7240-5 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: POINT TYPE HEAT DETECTORS
    02/540596 DC : DRAFT JULY 2002 PREN 54-17 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 17: SHORT CIRCUIT ISOLATORS
    BS EN 196103:2000 BLANK DETAIL SPECIFICATION: ROTARY SWITCHES - ASSESSMENT LEVEL Y
    02/106353 DC : DRAFT OCT 2002 EN 12966-1 - VERTICAL ROAD TRAFFIC SIGNS - PART 1: VARIABLE MESSAGE SIGNS
    I.S. EN 60439-4:2004 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR CONSTRUCTION SITES (ACS)
    09/30197779 DC : 0 BS ISO 7240-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO TRANSMISSION PATHS
    BS EN 50132-2-1:1998 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - BLACK AND WHITE CAMERAS
    DIN ISO 10109:2015-12 OPTICS AND PHOTONICS - GUIDANCE FOR THE SELECTION OF ENVIRONMENTAL TESTS (ISO 10109:2015)
    ISO 7240-8:2014 Fire detection and alarm systems Part 8: Point-type fire detectors using a carbon monoxide sensor in combination with a heat sensor
    I.S. EN 61810-7:2006 ELECTROMECHANICAL ELEMENTARY RELAYS - PART 7: TEST AND MEASUREMENT PROCEDURES
    ISO 7240-20:2010 Fire detection and alarm systems Part 20: Aspirating smoke detectors
    I.S. EN 61757-1:2012 FIBRE OPTIC SENSORS - PART 1: GENERIC SPECIFICATION (IEC 61757-1:2012 (EQV))
    I.S. EN 60512-11-14:2003 ELECTROMECHANICAL COMPONENTS FOR ELECTRONIC EQUIPMENT - BASIC TESTING PROCEDURES AND MEASURING METHODS - CLIMATIC TESTS - FLOWING SINGLE GAS CORROSION TEST
    I.S. EN 54-23:2010 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 23: FIRE ALARM DEVICES - VISUAL ALARM DEVICES
    PREN 54-7 : DRAFT 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONISATION
    BIS IS/ISO 7240-5 : 2003 FIRE DETECTION AND ALARM SYSTEMS - PART 5: POINT-TYPE HEAT DETECTORS
    I.S. EN 61114-2:1999 METHODS OF MEASUREMENT ON RECEIVING ANTENNAS FOR SATELLITE BROADCAST TRANSMISSION IN THE 11/12 GHZ BAND - PART 2: MECHANICAL AND ENVIRONMENTAL TESTS ON INDIVIDUAL AND COLLECTIVE RECEIVING ANTENNAS
    14/30274689 DC : 0 BS EN 54-20 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
    13/30277397 DC : 0 BS EN 54-11 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
    ASTM B 845 : 1997 : R2008 : EDT 1 Standard Guide for Mixed Flowing Gas (MFG) Tests for Electrical Contacts
    ASTM B 845 : 1997 : R2003 Standard Guide for Mixed Flowing Gas (MFG) Tests for Electrical Contacts
    ASTM B 845 : 1997 Standard Guide for Mixed Flowing Gas (MFG) Tests for Electrical Contacts
    IEC 60079-7:2015+AMD1:2017 CSV Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
    EN IEC 60079-7:2015/A1:2018 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017)
    BS EN 12094-2:2003 Fixed firefighting systems. Components for gas extinguishing systems Requirements and test methods for non-electrical automatic control and delay devices
    PD IEC/TS 62861:2017 GUIDELINES FOR PRINCIPAL COMPONENT RELIABILITY TESTING FOR LED LIGHT SOURCES AND LED LUMINAIRES
    UNE-EN 50290-4-1:2016 Communication cables - Part 4-1: General considerations for the use of cables - Environmental conditions and safety aspects
    10/30218813 DC : 0 BS EN 61439-4 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: ASSEMBLIES FOR CONSTRUCTION SITES (ACS)
    IEC 61230:2008 Live working - Portable equipment for earthing or earthing and short-circuiting
    DIN EN 54-17:2006-03 Fire detection and fire alarm systems - Part 17: Short-circuit isolators
    EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
    EN 60966-1:1999 Radio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test methods
    EN 60439-4:2004 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
    EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
    EN 12094-2:2003 Fixed firefighting systems - Components for gas extinguishing systems - Part 2: Requirements and test methods for non-electrical automatic control and delay devices
    EN 60512-11-14:2003 Connectors for electronic equipment - Tests and measurements - Part 11-14: Climatic tests - Test 11p: Flowing single gas corrosion test
    EN 61114-2:1996 Methods of measurement on receiving antennas for satellite broadcast transmission in the 11/12 GHz band - Part 2: Mechanical and environmental tests on individual and collective receiving antennas
    PREN 54-5 : DRAFT 2011 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT DETECTORS
    02/540552 DC : DRAFT JUN 2002 BS 5446-2 - FIRE DETECTION AND FIRE ALARM DEVICES FOR DWELLINGS - PART 2: SPECIFICATION FOR HEAT ALARMS
    08/30195238 DC : 0
    11/30236311 DC : 0 BS ISO 7240-10 - FIRE DETECTION AND ALARM SYSTEMS - PART 10: POINT-TYPE FLAME DETECTORS
    I.S. EN 54-29:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS
    05/30117311 DC : 0 EN 54-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS AND SYSTEM REQUIREMENTS
    04/30113660 DC : DRAFT MAY 2004 IEC 60079-7 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY 'E'
    BS EN 196403:2000 HARMONIZED SYSTEMS OF QUALITY ASSESSMENT FOR ELECTRONIC COMPONENTS - BLANK DETAIL SPECIFICATION: PUSH BUTTON SWITCHES - ASSESSMENT LEVEL Y
    03/114763 DC : DRAFT SEP 2003 EN 54-18 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 18: REQUIREMENTS AND TEST METHODS FOR INPUT/OUTPUT DEVICES FOR USE ON THE TRANSMISSION PATHS OF FIRE DETECTION AND FIRE ALARM SYSTEMS
    DIN EN 54-29:2015-06 Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors
    DIN EN 54-26:2015-11 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 26: CARBON MONOXIDE DETECTORS - POINT DETECTORS
    95/541995 DC : DRAFT AUG 1995 PREN ISO 12239 - SPECIFICATION FOR FIRE PROTECTION EQUIPMENT - SELF-CONTAINED SMOKE ALARMS
    ISO 7240-11:2011 Fire detection and alarm systems Part 11: Manual call points
    BS EN 61169-1:2013 Radio-frequency connectors Generic specification. General requirements and measuring methods
    DIN EN 54-24 E : 2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 24: COMPONENTS OF VOICE ALARM SYSTEMS - LOUDSPEAKERS
    NF EN 54-26 : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 26: CARBON MONOXIDE DETECTORS - POINT DETECTORS
    NF EN 54-27 : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 27: DUCT SMOKE DETECTORS
    DIN EN 54-26 E : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 26: CARBON MONOXIDE DETECTORS - POINT DETECTORS
    10/30234803 DC : 0 BS EN 61169-1 ED.2 - RADIO FREQUENCY CONNECTORS - PART 1: GENERIC SPECIFICATION - GENERAL REQUIREMENTS AND MEASURING METHODS
    NF EN 61020-1 : 2009 ELECTROMECHANICAL SWITCHES FOR USE IN ELECTRICAL AND ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION
    CEI EN 60512-11-14 : 2004 CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 11-14: CLIMATIC TESTS - TEST 11P: FLOWING SINGLE GAS CORROSION TEST
    95/541691 DC : 0 ISO/DIS 7240-5 - FIRE DETECTION AND ALARM SYSTEMS - POINT HEAT DETECTORS
    02/106354 DC : DRAFT OCT 2002 EN 12966-2 - VERTICAL ROAD TRAFFIC SIGNS - PART 2: VARIABLE MESSAGE SIGNS - INITIAL TYPE TESTING
    I.S. EN 54-26:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 26: CARBON MONOXIDE DETECTORS - POINT DETECTORS
    05/30127975 DC : DRAFT JAN 2005 ISO 7240-12 - FIRE DETECTION AND ALARM SYSTEMS - PART 12: LINE TYPE SMOKE DETECTORS USING A TRANSMITTING LIGHT BEAM
    CEI EN 61757-1 : 2013 FIBRE OPTIC SENSORS - PART 1: GENERIC SPECIFICATION
    NF EN 54-29 : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS
    PREN 54-28 : DRAFT 2015 FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NON-RESETTABLE LINE-TYPE HEAT DETECTORS
    DIN EN 54-30 E : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTISENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS
    IEC 61587-1:2016 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
    ISO 7240-18:2017 Fire detection and alarm systems — Part 18: Input/output devices
    I.S. EN 62146-1:2014 GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL
    BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
    BS EN 62146-1 : 2014 GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013)
    NF EN 54-30 : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS
    I.S. EN 61007:1998 TRANSFORMERS AND INDUCTORS FOR USE IN ELECTRONIC AND TELECOMMUNICATION EQUIPMENT - MEASURING METHODS AND TEST PROCEDURES
    BS EN 50019:2000 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY 'E'
    ISO 7240-25:2010 Fire detection and fire alarm systems Part 25: Components using radio transmission paths
    BS EN 54-7:2001 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    I.S. EN 54-5:2017 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS
    EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    BS EN 61587-1:2017 Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 series Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
    NF EN 61230 : 2009 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
    16/30315066 DC : 0 BS EN 14604 - SMOKE ALARM DEVICES
    I.S. EN 54-22:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS
    ISO 12239:2010 Smoke alarms using scattered light, transmitted light or ionization
    ASTM B 845 : 1997 : R2013 Standard Guide for Mixed Flowing Gas (MFG) Tests for Electrical Contacts
    BIS IS/ISO 7240-15 : 2004 FIRE DETECTION AND ALARM SYSTEMS - PART 15: POINT TYPE FIR E DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION SENSORS IN COMBINATION WITH A HEAT SENSOR
    NF EN 50132-4-1 : 2002 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 4-1: BLACK AND WHITE MONITORS
    IEC 61757:2018 Fibre optic sensors - Generic specification
    UNE-EN 54-3:2016 Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders
    DIN EN 54-23 :2010-06 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 23: FIRE ALARM DEVICES - VISUAL ALARM DEVICES
    DIN EN 14604:2016-02 (Draft) Smoke alarm devices; German and English version prEN 14604:2016
    DIN EN 54-20 E : 2009 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
    DIN EN 54-18 E : 2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 18: INPUT/OUTPUT DEVICES
    DIN EN 54-12 E : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM
    EN 54-22:2015 Fire detection and fire alarm systems - Part 22: Resettable line-type heat detectors
    DIN EN 54-10:2002-05 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
    DIN EN 54-3:2001-10 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
    I.S. EN ISO 10308:2006 METALLIC COATINGS - REVIEW OF POROSITY TESTS
    ISA 60079-7 : 2008 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E"
    BS 2011-2.1Kc:1991
    BS 5446-1:2000 FIRE DETECTION AND FIRE ALARM DEVICES FOR DWELLINGS - PART 1: SPECIFICATION FOR SMOKE ALARMS
    12/30256417 DC : 0 BS EN 54-31 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS
    PREN 50290-4-1 : DRAFT 2013 COMMUNICATION CABLES - PART 4-1: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - ENVIRONMENTAL CONDITIONS AND SAFETY ASPECTS
    11/30241337 DC : DRAFT JAN 2011 BS EN 61757-1 - FIBRE OPTIC SENSORS - PART 1: GENERIC SPECIFICATION
    ISO 7240-6:2011 Fire detection and alarm systems Part 6: Carbon monoxide fire detectors using electro-chemical cells
    10/30218017 DC : 0 BS ISO 7240-11 - FIRE DETECTION AND ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
    BS EN 54-22:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS
    05/30135124 DC : DRAFT JUN 2005 IEC 61587-1 ED 2 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND 60297 - PART 1: CLIMATIC, MECHANICAL TESTS AND SAFETY ASPECTS FOR CABINETS, RACKS AND SUBRACKS
    DIN CEN ISO/TS 14907-1;DIN SPEC 91192:2015-12 ELECTRONIC FEE COLLECTION - TEST PROCEDURES FOR USER AND FIXED EQUIPMENT - PART 1: DESCRIPTION OF TEST PROCEDURES (ISO/TS 14907-1:2015)
    ISO 7240-10:2012 Fire detection and alarm systems Part 10: Point-type flame detectors
    12/30235047 DC : 0 BS EN 62146-1 ED.1 - GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS
    NF EN 54-23 : 2010 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 23: FIRE ALARM DEVICES - VISUAL ALARM DEVICES
    14/30278882 DC : 0 BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
    ISO 7240-23:2013 Fire detection and alarm systems Part 23: Visual alarm devices
    NF EN 60512 11-14 : 2006 CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 11-14: CLIMATIC TESTS - TEST 11P: FLOWING SINGLE GAS CORROSION TEST
    04/30104415 DC : DRAFT AUG 2004 EN 54-20 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
    12/30254902 DC : DRAFT JAN 2012 BS EN 54-10 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
    DIN EN 54-22:2015-07 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS
    UNI EN 54-24 : 2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 24: COMPONENTS OF VOICE ALARM SYSTEMS - LOUDSPEAKERS
    BS EN 54-25:2008 Fire detection and fire alarm systems Components using radio links
    CEI EN 61587-1 : 2012 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITION USE AND TRANSPORTATION
    BS EN 54-30:2015 Fire detection and fire alarm systems Multi-sensor fire detectors. Point detectors using a combination of carbon monoxide and heat sensors
    11/30240406 DC : 0 BS ISO 7240-5 - FIRE DETECTION AND ALARM SYSTEMS - PART 5: POINT-TYPE HEAT DETECTORS
    BS EN 50290-4-1:2014 COMMUNICATION CABLES - PART 4-1: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - ENVIRONMENTAL CONDITIONS AND SAFETY ASPECTS
    BS EN 50136-2-1:1998 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2-1: GENERAL REQUIREMENTS FOR ALARM TRANSMISSION EQUIPMENT
    ISO 9022-20:2015 Optics and photonics Environmental test methods Part 20: Humid atmosphere containing sulfur dioxide or hydrogen sulfide
    DIN EN 54-7:2015-07 (Draft) FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    CEI EN 61114-2 : 1997 METHODS OF MEASUREMENT ON RECEIVING ANTENNAS FOR SATELLITE BROADCAST TRANSMISSION IN THE 11/12 GHZ BAND PART 2: MECHANICAL AND ENVIRONMENTAL TESTS ON INDIVIDUAL AND COLLECTIVE RECEIVING ANTENNAS
    I.S. EN 54-7:2000 COMPONENTS OF AUTOMATIC FIRE DETECTION SYSTEMS - POINT-TYPE SMOKE DETECTORS - DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    ISO/TS 7240-29:2017 Fire detection and alarm systems Part 29: Video fire detectors
    IEC 60300-3-5:2001 Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles
    NFS 61 023 : 2004 XP FIRE DETECTION SYSTEMS (FDS) USING RADIO LINKS
    EN 54-12:2015 Fire detection and fire alarm systems - Part 12: Smoke detectors - Line detectors using an optical beam
    ISO 7240-27:2009 Fire detection and alarm systems Part 27: Point-type fire detectors using a scattered-light, transmitted-light or ionization smoke sensor, an electrochemical-cell carbon-monoxide sensor and a heat sensor
    DIN EN 54-5:2001-03 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS
    ISO 10109:2015 Optics and photonics Guidance for the selection of environmental tests
    ISO 7240-17:2009 Fire detection and fire alarm systems Part 17: Short-circuit isolators
    ISO 7240-22:2017 Fire detection and alarm systems — Part 22: Smoke-detection equipment for ducts
    ISO 7240-24:2016 Fire detection and fire alarm systems Part 24: Fire alarm loudspeakers
    IEC 62103:2003 Electronic equipment for use in power installations
    I.S. EN 50290-4-1:2014 COMMUNICATION CABLES - PART 4-1: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - ENVIRONMENTAL CONDITIONS AND SAFETY ASPECTS
    I.S. EN 61587-1:2017 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITION USE AND TRANSPORTATION
    BS EN 54-17:2005 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 17: SHORT-CIRCUIT ISOLATORS
    IEC 61169-1:2013 Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods
    DIN EN 54-17 E : 2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 17: SHORT-CIRCUIT ISOLATORS
    UNI EN 54-3 : 2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
    EN 61007:1997 Transformers and inductors for use in electronic and telecommunication equipment - Measuring methods and test procedures
    UNI EN 54-23 : 2010 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 23: FIRE ALARM DEVICES - VISUAL ALARM DEVICES
    EN 50136-2-1 : 98 AMD 1 2001 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2-1: GENERAL REQUIREMENTS FOR ALARM TRANSMISSION EQUIPMENT
    UNI EN 54-20 : 2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
    UNI EN 14604 : 2005 SMOKE ALARM DEVICES
    NF EN 54-7 : 2001 AMD 2 2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    11/30242675 DC : 0 BS EN 60099-4 F2 - SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
    ISO 7240-12:2014 Fire detection and alarm systems Part 12: Line type smoke detectors using a transmitted optical beam
    11/30205538 DC : 0 BS EN 54-5 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT DETECTORS
    BS ISO 10109:2015 OPTICS AND PHOTONICS - GUIDANCE FOR THE SELECTION OF ENVIRONMENTAL TESTS
    95/541692 DC : 0 ISO/DIS 7240-7 - FIRE DETECTION AND ALARM SYSTEMS - SMOKE POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    05/30134095 DC : DRAFT MAY 2005 IEC 61587-1 ED 2 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND 60297 - PART 1: CLIMATIC, MECHANICAL TESTS AND SAFETY ASPECTS FOR CABINETS, RACKS AND SUBRACKS
    ISO 7240-15:2014 Fire detection and alarm systems Part 15: Point-type fire detectors using smoke and heat sensors
    08/30188489 DC : DRAFT AUG 2008 BS EN 54-27 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 27: DUCT SMOKE DETECTORS
    DIN ISO 9022-20:2015-06 OPTICS AND PHOTONICS - ENVIRONMENTAL TEST METHODS - PART 20: HUMID ATMOSPHERE CONTAINING SULFUR DIOXIDE OR HYDROGEN SULFIDE (ISO 9022-20:2015)
    13/30264600 DC : 0 BS EN 60747-14-8 ED 1.0 - SEMICONDUCTOR DEVICES - PART 14-8: SEMICONDUCTOR SENSORS - CAPACITIVE DEGRADATION SENSOR OF LIQUID
    11/30236274 DC : 0 BS ISO 7240-23 - FIRE DETECTION AND ALARM SYSTEMS - PART 23: VISUAL ALARM DEVICES
    DIN EN 54-3:2014-09 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
    CEI EN 60966-1 : 2001 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 1: GENERIC SPECIFICATION GENERAL REQUIREMENTS AND TEST METHODS
    BS EN 61007:1997 TRANSFORMERS AND INDUCTORS FOR USE IN ELECTRONIC AND TELECOMMUNICATION EQUIPMENT - MEASURING METHODS AND TEST PROCEDURES
    NF EN 54-22 : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS
    BS 7740(1994) : 1994 AMD 9060 PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
    PREN 50130-5 : DRAFT 2010 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
    14/30272874 DC : 0 BS ISO 7240-29 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: VIDEO FIRE DETECTORS
    BS ISO 7240-15:2014 FIRE DETECTION AND ALARM SYSTEMS - PART 15: POINT-TYPE FIRE DETECTORS USING SMOKE AND HEAT SENSORS
    BS EN 50130-5:2011 Alarm systems Environmental test methods
    06/30117299 DC : 0 BS EN 54-15 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 15: POINT DETECTORS USING A COMBINATION OF DETECTED FIRE PHENOMENA
    BS PD6521(1988) : 1988 SUMMARIES OF TEST METHODS FOR ENVIRONMENTAL TESTING OF ELECTROTECHNICAL PRODUCTS
    15/30290851 DC : 0 BS EN 54-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
    BS EN 54-27:2015 FIRE DETECTION AND FIRE ALARMS SYSTEMS - PART 27: DUCT SMOKE DETECTORS
    07/30170224 DC : DRAFT AUG 2007 BS EN 61230 - LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
    BS EN 61810-7:2006 Electromechanical elementary relays Test and measurement procedures
    UNI EN 54-25 : 2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
    DIN ISO 10109 E : 2015 OPTICS AND PHOTONICS - GUIDANCE FOR THE SELECTION OF ENVIRONMENTAL TESTS (ISO 10109:2015)
    UNE-EN 61439-4:2013 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
    IEEE 1246 : 2011 GUIDE FOR TEMPORARY PROTECTIVE GROUNDING SYSTEMS USED IN SUBSTATIONS
    S.R. CEN ISO/TS 14907-1:2015 ELECTRONIC FEE COLLECTION - TEST PROCEDURES FOR USER AND FIXED EQUIPMENT - PART 1: DESCRIPTION OF TEST PROCEDURES (ISO/TS 14907-1:2015)
    ISO 7240-7:2011 Fire detection and alarm systems Part 7: Point-type smoke detectors using scattered light, transmitted light or ionization
    I.S. EN 54-28:2016 FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NON-RESETTABLE LINE-TYPE HEAT DETECTORS
    I.S. EN 54-30:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS
    I.S. EN 54-3:2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
    BIS IS/ISO 7240-11 : 2011 FIRE DETECTION AND ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
    15/30296472 DC : 0 BS EN 54-7 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    I.S. EN 54-12:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM
    I.S. EN 54-24:2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 24: COMPONENTS OF VOICE ALARM SYSTEMS - LOUDSPEAKERS
    CEI EN 61810-7 : 2006 ELECTROMECHANICAL ELEMENTARY RELAYS - PART 7: TEST AND MEASUREMENT PROCEDURES
    ISO 7240-3:2010 Fire detection and alarm systems Part 3: Audible alarm devices
    I.S. EN 61020-1:2009 ELECTROMECHANICAL SWITCHES FOR USE IN ELECTRICAL AND ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION
    I.S. EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
    I.S. EN 61169-1:2013 RADIO-FREQUENCY CONNECTORS - PART 1: GENERIC SPECIFICATION - GENERAL REQUIREMENTS AND MEASURING METHODS
    I.S. EN 61300-2-28:2013 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-28: TESTS - INDUSTRIAL ATMOSPHERE (SULPHUR DIOXIDE) (IEC 61300-2-28:2013 (EQV))
    I.S. EN 54-25:2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
    IEC 61007:1994 Transformers and inductors for use in electronic and telecommunication equipment - Measuring methods and test procedures
    EN 61169-1:2013/AC:2016-02 RADIO-FREQUENCY CONNECTORS - PART 1: GENERIC SPECIFICATION - GENERAL REQUIREMENTS AND MEASURING METHODS (IEC 61169-1:2013)
    DIN EN 14604 E : 2009 SMOKE ALARM DEVICES
    BS EN 54-12:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM
    BS EN 54-23:2010 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 23: FIRE ALARM DEVICES - VISUAL ALARM DEVICES
    95/214868 DC : 0 PREN 50178 - ELECTRONIC EQUIPMENT FOR USE IN POWER INSTALLATIONS
    IEC 61300-2-28:2013 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-28: Tests - Corrosive atmosphere (sulphur dioxide)
    BS EN 54-10:2002 Fire detection and fire alarm systems Flame detectors. Point detectors
    BS EN 60439-4:2004 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR CONSTRUCTION SITES (ACS)
    DIN EN 54-10 E : 2002 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
    03/100155 DC : DRAFT JAN 2003 IEC 60439-4 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR CONSTRUCTION SITES (ACS)
    ISO/TS 14907-1:2015 Electronic fee collection Test procedures for user and fixed equipment Part 1: Description of test procedures
    IEC 61020-1:2009 Electromechanical switches for use in electrical and electronic equipment - Part 1: Generic specification
    IEC 60966-1:1999 Radio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test methods
    IEC 61747-1:1998+AMD1:2003 CSV Liquid crystal and solid-state display devices - Part 1: Generic specification
    BS EN 54-5 : 2017 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS
    DIN EN 54-12:2015-10 Fire detection and fire alarm systems - Part 12: Smoke detectors - Line detectors using an optical beam
    IEC 61439-4:2012 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
    IEC 62146-1:2013+AMD1:2016 CSV Grading capacitors for high-voltage alternating current circuit-breakers - Part 1: General
    09/30207398 DC : 0 BS ISO 7240-3 - FIRE DETECTION AND ALARM SYSTEMS - PART 3: AUDIBLE ALARM DEVICES
    BS EN 12094-1:2003 Fixed firefighting systems. Components for gas extinguishing systems Requirements and test methods for electrical automatic control and delay devices
    BS EN 54-18:2005 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 18: INPUT/OUTPUT DEVICES
    BS EN 54-20:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
    DIN EN 54-20:2009-02 Fire detection and fire alarm systems - Part 20: Aspirating smoke detectors (includes Amendment AC:2008)
    DIN EN 54-18:2006-03 Fire detection and fire alarm systems - Part 18: Input/output devices
    12/30248102 DC : 0 BS EN 14604 - SMOKE ALARM DEVICES
    IEC 61757-1:2012 Fibre optic sensors - Part 1: Generic specification
    EN 54-26:2015 Fire detection and fire alarm systems - Part 26: Carbon monoxide detectors - Point detectors
    EN 54-29 : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS
    EN 54-23:2010 Fire detection and fire alarm systems - Part 23: Fire alarm devices - Visual alarm devices
    EN 54-28:2016 Fire detection and fire alarm system - Part 28: Non-resettable line-type heat detectors
    EN 54-3:2014 Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders
    EN ISO 10308:2006 Metallic coatings - Review of porosity tests (ISO 10308:2006)
    EN 54-24:2008 Fire detection and fire alarm systems - Part 24: Components of voice alarm systems - Loudspeakers
    EN 54-17:2005/AC:2007 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 17: SHORT-CIRCUIT ISOLATORS
    EN 14604:2005/AC:2008 SMOKE ALARM DEVICES
    EN 54-27:2015 Fire detection and fire alarms systems - Part 27: Duct smoke detectors
    EN 54-20:2006/AC:2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
    EN 54-11:2001/A1:2005 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
    EN 54-10:2002/A1:2005 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
    EN 54-18:2005/AC:2007 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 18: INPUT/OUTPUT DEVICES
    EN 54-31:2014+A1:2016 Fire detection and fire alarm systems - Part 31: Multi-sensor fire detectors - Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors
    EN 54-30 : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS
    I.S. EN 61439-4:2013 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR CONSTRUCTION SITES (ACS) (IEC 61439-4:2012 (EQV))
    DIN EN 54-22 E : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS
    DIN EN 54-27 E : 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 27: DUCT SMOKE DETECTORS
    EN 61587-1:2017 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation
    ETR 344 : 20001 TERMINAL EQUIPMENT (TE) - THE TECHNICAL FEASIBILITY OF A HARMONIZED PLUG AND SOCKET STANDARD
    16/30353588 DC : 0 BS EN 61020-1 ED 3.0 - ELECTROMECHANICAL SWITCHES FOR USE IN ELECTRICAL AND ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION
    11/30205541 DC : 0 BS EN 54-7 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONISATION
    BS EN 54-29:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS
    CEI EN 61300-2-28 : 2014 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-28: TESTS - INDUSTRIAL ATMOSPHERE (SULPHUR DIOXIDE)
    NF EN 50136-2-1 : 98 AMD 1 2002 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2-1: GENERAL REQUIREMENTS FOR EQUIPMENT USED IN SYSTEMS USING DEDICATED ALARM PATHS
    BS EN 60966-1:1999 (published 1999-10) Radio frequency and coaxial cable assemblies Generic specification. General requirements and test methods
    BS EN 50132-4-1:2001 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS PART 4-1: BLACK AND WHITE MONITORS
    IEC 62599-1:2010 Alarm systems - Part 1: Environmental test methods
    BS EN 61020-1:2009 (published 2013-05) Electromechanical switches for use in electrical and electronic equipment Generic specification
    UNE-EN 50130-5:2011 Alarm systems - Part 5: Environmental test methods
    13/30264596 DC : 0 BS EN 60747-14-7 ED 1.0 - SEMICONDUCTOR DEVICES - PART 14-7: SEMICONDUCTOR SENSORS - FLOW METER
    PREN 54-25 : DRAFT 2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
    10/30219087 DC : 0 BS EN 61587-1 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 1: ENVIRONMENTAL REQUIREMENTS AND TESTS, SAFETY ASPECTS FOR FOR CABINETS, RACKS, SUBRACKS AND CHASSIS
    13/30291609 DC : 0 BS EN 60966-1 - RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 1: GENERIC SPECIFICATION - GENERAL REQUIREMENTS AND TEST METHODS
    BS EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
    DIN EN 54-30:2015-11 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS
    DIN EN 54-27:2015-05 Fire detection and fire alarm systems - Part 27: Duct smoke detectors
    BS EN 54-26:2015 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 26: CARBON MONOXIDE DETECTORS - POINT DETECTORS
    10/30228868 DC : 0 BS EN 61300-2-28 - FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-28: TESTS - INDUSTRIAL ATMOSPHERE (SULPHUR DIOXIDE)
    98/704428 DC : DRAFT FEB 1998 ISO/CD 16100 - AUTOMATIC INTEGRATED ENVIRONMENTAL CONTROL SYSTEMS
    BS EN 54-24:2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 24: COMPONENTS OF VOICE ALARM SYSTEMS - LOUDSPEAKERS
    13/30268917 DC : 0 BS EN 50290-4-1 ED.2 PREN 50290-4-1 ED.2 - COMMUNICATION CABLES - PART 4-1: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - ENVIRONMENTAL CONDITIONS AND SAFETY ASPECTS
    CSA E60079.7 : 2003 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY "E"
    BS EN 60512-11-14:2003 (published 2003-11) Connectors for electronic equipment. Tests and measurements. Climatic tests Flowing single gas corrosion test
    15/30291072 DC : 0 BS EN 54-28 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 28: NON-RESETTABLE LINE TYPE HEAT DETECTORS
    BIS IS/IEC 60079-7 : 2006 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
    CEI EN 50130-5 : 2012 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
    PREN 54-3 : DRAFT 2009 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
    I.S. EN 60079-7:2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
    BIS IS/ISO 7240-7 : 2011 FIRE DETECTION AND ALARM SYSTEMS - PART 7: POINT-TYPE SMOKE DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    I.S. EN 54-31:2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS
    I.S. EN 54-27:2015 FIRE DETECTION AND FIRE ALARMS SYSTEMS - PART 27: DUCT SMOKE DETECTORS
    IEC 60512-11-14:2003 Connectors for electronic equipment - Tests and measurements - Part 11-14: Climatic tests - Test 11p: Flowing single gas corrosion test
    DIN EN 54-24:2008-06 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 24: COMPONENTS OF VOICE ALARM SYSTEMS - LOUDSPEAKERS
    NF EN 50132-2-1 : 1997 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 2-1: BLACK AND WHITE CAMERAS
    I.S. EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
    ONORM EN 54-7 : 2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    ASTM B 845 : 1997 : R2008 : EDT 2 Standard Guide for Mixed Flowing Gas (MFG) Tests for Electrical Contacts
    DIN EN 54-25:2015-10 (Draft) FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
    ASTM B 845 : 1997 : R2013 : EDT 2 Standard Guide for Mixed Flowing Gas (MFG) Tests for Electrical Contacts
    ASTM B 845 : 1997 : R2013 : EDT 1 Standard Guide for Mixed Flowing Gas (MFG) Tests for Electrical Contacts
    I.S. EN 50019:2001 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
    DIN EN ISO 10308:2006-04 METALLIC COATINGS - REVIEW OF POROSITY TESTS
    IEC 60439-4:2004 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
    IEC 61810-7:2006 Electromechanical elementary relays - Part 7: Test and measurement procedures
    BS EN 14604:2005 Smoke alarm devices
    BS EN 54-3:2014 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 3: FIRE ALARM DEVICES - SOUNDERS
    IEC TS 62861:2017 Guidelines for principal component reliability testing for LED light sources and LED luminaires
    ISO 10308:2006 Metallic coatings Review of porosity tests
    EN 50290-4-1:2014 Communication cables - Part 4-1: General considerations for the use of cables - Environmental conditions and safety aspects
    EN 61757-1 : 2012 FIBRE OPTIC SENSORS - PART 1: GENERIC SPECIFICATION (IEC 61757-1:2012)
    EN 62146-1:2014/A1:2016 GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013/A1:2016)
    DIN EN 54-28:2016-07 Fire detection and fire alarm system - Part 28: Non-resettable line-type heat detectors
    EN 61300-2-28:2013 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-28: TESTS - INDUSTRIAL ATMOSPHERE (SULPHUR DIOXIDE)
    EN 12094-1:2003 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices
    EN 50132-4-1 : 2001 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 4-1: BLACK AND WHITE MONITORS
    EN 61810-7:2006 Electromechanical elementary relays - Part 7: Test and measurement procedures
    EN 50019:2000/corrigendum Apr. 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
    EN 50132-2-1 : 1997 ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - BLACK AND WHITE CAMERAS
    DIN EN 12094-2:2003-09 Fixed firefighting systems - Components for gas extinguishing systems - Part 2: Requirements and test methods for non-electrical automatic control and delay devices; German version EN 12094-2:2003
    CEN ISO/TS 14907-1:2015 Electronic fee collection - Test procedures for user and fixed equipment - Part 1: Description of test procedures (ISO/TS 14907-1:2015)
    EN 54-25:2008/AC:2012 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS
    EN 61439-4:2013 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
    DIN VDE 0660-501 : 1992 SWITCHGEAR AND CONTROLGEAR; LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR CONSTRUCTION SITES (ACS)
    EN 61020-1:2009 Electromechanical switches for use in electrical and electronic equipment - Part 1: Generic specification

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    IEC 60068-2-49:1983 Basic environmental testing procedures - Part 2-49: Tests - Guidance to test Kc: Sulphur dioxide test for contacts and connections
    IEC 60512-2-1:2002 Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective