• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 60708:2005

Current
Current

The latest, up-to-date edition.

Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

24-06-2005

FOREWORD
1 Scope
2 Normative references
3 Quality assurance
4 Cable construction
  4.1 Conductor
       4.1.1 Conductor material
       4.1.2 Type of conductor
       4.1.3 Conductor-finish
       4.1.4 Continuity of conductor
  4.2 Insulation
       4.2.1 Insulation material
       4.2.2 Insulation thickness
       4.2.3 Colour of insulated conductor
  4.3 Cabling element
  4.4 Stranding
  4.5 Colour code
       4.5.1 General
       4.5.2 Sub-units, units and cables up to and including
              100 pairs or 100 quads
       4.5.3 Cables of more than 100 pairs or 100 quads
  4.6 Spare pairs or quads
  4.7 Filling
  4.8 Core protection
  4.9 Sheath
       4.9.1 Sheath material
       4.9.2 Application of the sheath
  4.10 Cable protection
  4.11 Finished cable
       4.11.1 Overall diameter
       4.11.2 Sheath marking
       4.11.3 Sealing of ends
  4.12 Delivery
5 Mechanical requirements
  5.1 Conductor
  5.2 Insulation
  5.3 Sheath
       5.3.1 Tensile strength and elongation
       5.3.2 Adhesion of aluminium tape to the polyethylene
       5.3.3 Adhesion of aluminium tape at the overlap
  5.4 Finished cable
       5.4.1 Sheath integrity
       5.4.2 Resistance to water penetration
       5.4.3 Cable drip
6 Thermal stability and environmental requirements
  6.1 Insulation
       6.1.1 Thermal oxidative stability (OIT-test)
       6.1.2 Shrinkage
       6.1.3 Wrapping test of insulation after thermal aging
       6.1.4 Bending test at low temperature
  6.2 Sheath
       6.2.1 Elongation at break after ageing
       6.2.2 Resistance to weathering
       6.2.3 Resistance to environmental stress cracking
7 Electrical requirements
  7.1 General
  7.2 Electrical resistance of conductor
  7.3 Electrical resistance unbalance
  7.4 Dielectric strength
  7.5 Insulation resistance
  7.6 Mutual capacitance
  7.7 Capacitance unbalance
  7.8 Transmission characteristics (when used for digital
       communication)
       7.8.1 Attenuation
       7.8.2 Near End Crosstalk (NEXT)
       7.8.3 Equal Level Far-end Crosstalk (ELFEXT)
       7.8.4 Power sum (PS) of crosstalk loss
       7.8.5 Characteristic impedance
       7.8.6 Velocity of propagation
Annex A (normative) Colour code: 10 pair or 5 quad count
Annex B (normative) Colour code: sub-unit identification for
                    50 pair (25 quad) and 100 pair (50 quad)
                    cables or units, using 10 pair or 5 quad
                    count
Annex C (normative) Colour code: 25 pair count
Annex D (normative) Colour code: unit identification for
                    50 pair or quad and 100 pair or quad
                    cables or units, using 25 pair or quad
                    count
Annex E (normative) Colour code: 25 quad count
Annex F (normative) Colour code: unit identification for
                    cables with more than 100 pairs, 25 pair
                    count
Annex G (normative) Colour code: unit identification for
                    cables with more than 100 pairs or 50 quads,
                    using 10 pair or 5 quad count or 25 quad
                    count

IEC 60708:2005 is intended to define polyolefin insulated cables for insertion into local outdoor networks. Is applicable to polyolefin insulated and moisture barrier polyolefin sheathed telephone cables, filled or unfilled with copper conductors, includes general design details and requirements for dimensions and other constructional details as well as mechanical, electrical and environmental characteristics for all types of low-frequency cables with polyolefin insulation (solid or cellular), filled or unfilled, and moisture barrier polyolefin sheath (with integral suspension strand). The contents of the corrigendum of August 2016 have been included in this copy.

Committee
TC 46/SC 46C
DevelopmentNote
Supersedes IEC 60708-1. (06/2005) Stability Date: 2020. A Bilingual edition has been published on 08/04/2014. (04/2014)
DocumentType
Standard
Pages
26
PublisherName
International Electrotechnical Committee
Status
Current

BS EN 50288-8:2012 Multi-element metallic cables used in analogue and digital communication and control Specification for type 1 cables characterised up to 2 MHz
PREN 50288-11-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
BS EN 50288-7:2005 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for instrumentation and control cables
BS EN 60695-1-40:2014 Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products. Insulating liquids
PREN 50288-12-1 : DRAFT 2016 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 12-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERISED FROM 1 MHZ UP TO 2000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
BS EN 50288-11-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for un-screened cables characterised up to 500 MHz. Horizontal and building backbone cables
I.S. EN 50288-9-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERISED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
10/30216201 DC : 0 BS EN 50882-11 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES, CHARACTERISED UP TO 500 MHZ, FOR HORIZONTAL AND BUILDING BACKBONE WIRING
BS EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
PREN 50288-9-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ - WORK AREA, PATCH CORD AND DATA CENTRE CABLES
DIN EN 187102 : 1996 FAMILY SPECIFICATION: OPTICAL AERIAL TELECOMMUNICATION CABLES
I.S. EN 50288-11-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES, CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
I.S. EN 50288-10-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
I.S. EN 50288-8:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 8: SPECIFICATION FOR TYPE 1 CABLES CHARACTERISED UP TO 2 MHZ
IEC 60695-1-40:2013 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids
EN 50288-9-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 9-1: Sectional specification for screened cables characterised up to 1 000 MHz - Horizontal and building backbone cables
EN 60794-3:2015 Optical fibre cables - Part 3: Sectional specification - Outdoor cables
EN 50288-9-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 9-2: Sectional specification for screened cables characterized from 1 MHz up to 1 000 MHz for work area, patch cord and data centre applications
EN 50288-10-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 10-1: Sectional specification for screened cables characterized up to 500 MHz - Horizontal floor and building backbone cables
10/30216235 DC : 0 BS EN 50288-10 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10: SECTIONAL SPECIFICATION FOR CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
I.S. EN 45510-2-9:2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
DIN EN 187101 : 1996 FAMILY SPECIFICATION: OPTICAL TELECOMMUNICATION CABLES TO BE USED IN DUCTS OR DIRECT BURIED APPLICATION
NF EN 60794-3-11 : 2011 OPTICAL FIBRE CABLES - PART 3-11: OUTDOOR CABLES - PRODUCT SPECIFICATION FOR DUCT, DIRECTLY BURIED, AND LASHED AERIAL SINGLE-MODE OPTICAL FIBRE TELECOMMUNICATION CABLES
PREN 50288-10 : DRAFT 2010 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10: SECTIONAL SPECIFICATION FOR CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
PREN 50288-9-1 : DRAFT 2010 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
CEI EN 60794-3-11 : 2012 OPTICAL FIBRE CABLES - PART 3-11: OUTDOOR CABLES - PRODUCT SPECIFICATION FOR DUCT, DIRECTLY BURIED AND LASHED AERIAL SINGLE-MODE OPTICAL FIBRE TELECOMMUNICATION CABLES
UNE-EN 50288-11-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 11-1: Sectional specification for un-screened cables characterised up to 500 MHz - Horizontal and building backbone cables
I.S. EN 60794-3-11:2010 OPTICAL FIBRE CABLES - PART 3-11: OUTDOOR CABLES - PRODUCT SPECIFICATION FOR DUCT, DIRECTLY BURIED AND LASHED AERIAL SINGLE-MODE OPTICAL FIBRE TELECOMMUNICATION CABLES
I.S. EN 50288-9-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
I.S. EN 50173-1:2011 INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS
I.S. EN 50288-7:0 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 7: SECTIONAL SPECIFICATION FOR INSTRUMENTATION AND CONTROL CABLES
BS EN 50288-9-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterised up to 1 000 MHz. Horizontal and building backbone cables
13/30277706 DC : 0 BS EN 50288-11-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
16/30331040 DC : 0 BS EN 50288-12-1 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 12-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERISED FROM 1 MHZ UP TO 2000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
BS EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
BS EN 50288-12-1:2017 Multi-element metallic cables used in analogue and digital communications and control Sectional specification for screened cables characterised from 1 MHz up to 2 000 MHz. Horizontal and building backbone cables
UNE-EN 50288-10-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 10-1: Sectional specification for screened cables characterized up to 500 MHz - Horizontal floor and building backbone cables
CEI EN 50173-1 : 2011 INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS
EN 50288-12-1:2017 Multi-element metallic cables used in analogue and digital communications and control - Part 12-1: Sectional specification for screened cables characterised from 1 MHz up to 2 000 MHz - Horizontal and building backbone cables
I.S. EN 50288-10-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL FLOOR AND BUILDING BACKBONE CABLES
UNE-EN 50288-8:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 8: Specification for type 1 cables characterised up to 2 MHz
I.S. EN 60695-1-40:2014 FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS
I.S. EN 60794-3:2002 OPTICAL FIBRE CABLES - PART 3: SECTIONAL SPECIFICATION - OUTDOOR CABLES
I.S. EN 50288-12-1:2017 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 12-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERISED FROM 1 MHZ UP TO 2000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
IEC 62255-1:2003 Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 1: Generic specification
EN 45510-2-9:2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
BS 3573:1990 Specification for polyolefin copper-conductor telecommunication cables
13/30260675 DC : 0 BS EN 50288-10-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
UNE-EN 60695-1-40:2014 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids
13/30260672 DC : 0 BS EN 50288-9-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ - WORK AREA, PATCH CORD AND DATA CENTRE CABLES
BS EN 50288-10-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized up to 500 MHz. Horizontal floor and building backbone cables
10/30216188 DC : 0 BS EN 50288-9-1 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
BS EN 60794-3-11:2010 Optical fibre cables Outdoor cables. Product specification for duct, directly buried and lashed aerial single-mode optical fibre telecommunication cables
PREN 50288-10-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
EN 50173-1:2011 Information technology - Generic cabling systems - Part 1: General requirements
IEC 60794-3:2014 Optical fibre cables - Part 3: Outdoor cables - Sectional specification
EN 45510-2-9 : 2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
I.S. EN 50288-11-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-1: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERISED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
BS EN 50173-1:2011 Information technology. Generic cabling systems General requirements
09/30197559 DC : 0 BS EN 60794-3-11 ED.2 - OPTICAL FIBRE CABLES - PART 3-11: OUTDOOR CABLES - PRODUCT SPECIFICATION FOR DUCT AND DIRECTLY BURIED SINGLE-MODE OPTICAL FIBRE TELECOMMUNICATION CABLES
UNE-EN 50288-12-1:2017 Multi-element metallic cables used in analogue and digital communications and control - Part 12-1: Sectional specification for screened cables characterised from 1 MHz up to 2 000 MHz - Horizontal and building backbone cables
UNE-EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 10-2: Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
CEI EN 60695-1-40 : 2014 FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS
UNE-EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 11-2: Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
UNE-EN 50288-9-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 9-1: Sectional specification for screened cables characterised up to 1 000 MHz - Horizontal and building backbone cables
BS EN 60794-3:2015 Optical fibre cables Sectional specification. Outdoor cables
IEC 61156-1:2007+AMD1:2009 CSV Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification
BS EN 45510-2-9:2008 Guide for procurement of power station equipment Electrical equipment. Cabling systems
IEC 60794-3-11:2010 Optical fibre cables - Part 3-11: Outdoor cables - Product specification for duct, directly buried, and lashed aerial single-mode optical fibre telecommunication cables
EN 50288-11-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 11-1: Sectional specification for un-screened cables characterised up to 500 MHz - Horizontal and building backbone cables
EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 10-2: Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
EN 60794-3-11:2010 Optical fibre cables - Part 3-11: Outdoor cables - Product specification for duct, directly buried and lashed aerial single-mode optical fibre telecommunication cables
EN 60695-1-40:2014 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids
EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 11-2: Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
EN 50288-7:2005 Multi-element metallic cables used in analogue and digital communication and control - Part 7: Sectional specification for instrumentation and control cables
EN 50288-8:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 8: Specification for type 1 cables characterised up to 2 MHz

IEC 60028:1925 International standard of resistance for copper
IEC 60811-4-1:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
IEC 60189-1:2007 Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods
IEC 60304:1982 Standard colours for insulation for low-frequency cables and wires
IEC 60794-1-2:2017 Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance
IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
IEC 61156-1:2007+AMD1:2009 CSV Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification
IEC 60811-4-2:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Wrapping test after conditioning at elevated temperature - Wrapping test after thermal ageing in air - Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
IEC 60811-5-1:1990+AMD1:2003 CSV Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop-point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - DC resistivity at 23 °C and 100 °C
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature

View more information
£178.24
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.