Automatic electrical controls for household and similar use - Part 2-2: Particular requirements for thermal motor protectors
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

10-04-2015

Language(s)

English - French

Published date

20-09-2005

FOREWORD
1 Scope and normative references
2 Definitions
3 General requirements
4 General notes on tests
5 Rating
6 Classification
7 Information
8 Protection against electric shock
9 Provision for protective earthing
10 Terminals and terminations
11 Constructional requirements
12 Moisture and dust resistance
13 Electric strength and insulation resistance
14 Heating
15 Manufacturing deviation and drift
16 Environmental stress
17 Endurance
18 Mechanical strength
19 Threaded parts and connections
20 Creepage distances, clearances and distances through
   insulation
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
23 Electromagnetic compatibility (EMC) requirements -
   emission
24 Components
25 Normal operation
26 Electromagnetic compatibility (EMC) requirements -
   Immunity
27 Abnormal operation
28 Guidance on the use of electronic disconnection
Annex C (normative) Cotton used for mercury switch test
Annex D (informative) Heat, fire and tracking (applicable in
        Canada and the USA)
Annex E (normative) Circuit for measuring leakage current
Annex H (normative) Requirements for electronic controls
Annex AA (informative) Testing of the combination of motor
                       and thermal motor protectors
Annex BB (informative) General comments on thermal motor
                       protectors which may help reduce
                       testing

This part of IEC 60730 applies to the partial evaluation of thermal motor protectors, as defined in IEC 60730-1, for household and similar use, including heating, air conditioning and similar applications.This consolidated version consists of the second edition (2001) and its amendment 1 (2005). Therefore, no need to order amendment inaddition to this publication.

Committee
TC 72
DevelopmentNote
Stability Date: 2013. (10/2012)
DocumentType
Standard
Pages
45
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

PD CLC/TR 50455:2008 List of interpretations on the EN 60730 series \'Automatic electrical controls for household and similar use\'
CLC/TR 50455:2008 List of interpretations on the EN 60730 series "Automatic electrical controls for household and similar use"
S.R. CLC/TR 50455:2008 LIST OF INTERPRETATIONS ON THE EN 60730 SERIES "AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE"

CISPR 14-1:2016 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60038:2009 IEC standard voltages
IEC 60738-1:2006+AMD1:2009 CSV Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification
IEC 60127:1974 Cartridge fuse-links for miniature fuses
IEC 60384-14:2013+AMD1:2016 CSV Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 60539:1976 Directly heated negative temperature coefficient thermistors
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEC 60998-2-2:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units
IEC 60707:1999 Flammability of solid non-metallic materials when exposed to flame sources - List of test methods
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 61058-1:2016 Switches for appliances - Part 1: General requirements
IEC 60738-1-1:2008 Thermistors - Directly heated positive step-function temperature coefficient - Part 1-1: Blank detail specification - Current limiting application - Assessment level EZ
IEC 60099-1:1991+AMD1:1999 CSV Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 60423:2007 Conduit systems for cable management - Outside diameters of conduits for electrical installations and threads for conduits and fittings
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60216-1:2013 Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)

View more information
£201.70
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.