IEC 60831-1 REDLINE : 3ED 2014

Current
Current

The latest, up-to-date edition.

SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
Published date

18-02-2014

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Test requirements
6 Classification of tests
7 Capacitance measurement and output calculation
8 Measurement of the tangent of the loss angle
   (tan [delta]) of the capacitor
9 Voltage tests between terminals
10 Voltage tests between terminals and container
11 Test of internal discharge device
12 Sealing test
13 Thermal stability test
14 Measurement of the tangent of the loss angle
   (tan [delta]) of the capacitor at elevated temperature
15 Lightning impulse voltage test between terminals
   and container
16 Discharge test
17 Ageing test
18 Self-healing test
19 Destruction test
20 Maximum permissible voltage
21 Maximum permissible current
22 Discharge device
23 Container connections
24 Protection of the environment
25 Other safety requirements
26 Marking of the unit
27 Marking of the bank
28 General
29 Choice of the rated voltage
30 Operating temperature
31 Special service conditions
32 Overvoltages
33 Overload currents
34 Switching and protective devices and connections
35 Choice of creepage distance
36 Capacitors connected to systems with audio-frequency
   remote control
37 Electromagnetic compatibility (EMC)
Annex A (normative) - Additional definitions, requirements
        and tests for power filter capacitors
Annex B (informative) - Formulae for capacitors and
        installations
Bibliography

Pertains to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage up to and including 1000 V and frequencies of 15 Hz to 60 Hz.

Committee
TC 33
DevelopmentNote
Stability date: 2020. (11/2017)
DocumentType
Standard
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
UNE-EN 60831-1:2014 Identical

IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
IEC 60143-2:2012 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
IEC 60143-1:2015 Series capacitors for power systems - Part 1: General
IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 61048:2006+AMD1:2015 CSV Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC TR 60996:1989 Method for verifying accuracy of tan delta measurements applicable to capacitors
IEC 61049:1991 Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements
IEC 60695-2-12:2010+AMD1:2014 CSV Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials
IEC 60721-2-6:1990 Classification of environmental conditions. Part 2: Environmental conditions appearing in nature. Earthquake vibration and shock
IEC 60831-2:2014 Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 2: Ageing test, self-healing test and destruction test
IEC 60273:1990 Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V
IEC 60358-1:2012 Coupling capacitors and capacitor dividers - Part 1: General rules
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
IEC 60252-1:2010+AMD1:2013 CSV AC motor capacitors - Part 1: General - Performance, testing andrating - Safety requirements - Guidance for installation and operation
IEC 60050-436:1990 International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60143-3:2015 Series capacitors for power systems - Part 3: Internal fuses
IEC 60143-4:2010 Series capacitors for power systems - Part 4: Thyristor controlled series capacitors
IEC 60110-1:1998 Power capacitors for induction heating installations - Part 1: General

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.