FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
4.1 Temperature classification
4.2 Level of protection
4.3 Level of protection "maD"
4.4 Level of protection "mbD"
4.5 Supply specifications
5 Requirements for compounds
5.1 General
5.2 Specification
6 Temperature
6.1 General
6.2 Temperature limitation
6.3 Determination of the limiting temperature values
7 Constructional requirements
7.1 General
7.2 Determination of possible faults
7.3 Switching contacts
7.4 External connections
7.5 Protection of bare live parts
7.6 Cells and batteries
7.7 Protective devices
8 Type tests
8.1 Tests on the compound - water absorption test
8.2 Tests on the apparatus
9 Routine verifications and tests
9.1 Visual inspections
9.2 Dielectric strength test
10 Marking
Annex A (informative) Basic requirements for compounds
for encapsulation "mD" apparatus
Annex B (normative) Allocation of test samples
Annex C (normative) Test procedure during thermal cycling test
Figures
Tables
Applicable to electrical apparatus protected by encapsulation type of protection "mD" and surface temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. Specifies requirements for design, construction and testing of electrical apparatus, parts of electrical apparatus and Ex components where the rated voltage does not exceed 10 kV.The application of electrical apparatus in atmospheres which may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protective measures.
DevelopmentNote |
To be read in conjunction with IEC 61241-0. (08/2004)
|
DocumentType |
Standard
|
Pages |
65
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
DIN EN 61241-18 : 2005 | Identical |
NF EN 61241-18 : 2005 | Identical |
GOST IEC 61241-18 : 2011 | Identical |
NEN EN IEC 61241-18 : 2004 | Identical |
I.S. EN 61241-18:2004 | Identical |
PN EN 61241-18 : 2005 | Identical |
SANS 61241-18 : 1ED 2005 | Identical |
AS/NZS 61241.18:2005 | Identical |
VDE 0170-15-18 : 2005 | Identical |
UNE-EN 61241-18:2006 | Identical |
BIS IS/IEC 61241-18 : 2004 | Identical |
BS EN 61241-18:2004 | Identical |
CEI EN 61241-18 : 2007 | Identical |
EN 61241-18:2004 | Identical |
GOST R IEC 61241-18 : 2009 | Identical |
BS EN 61241-17:2005 | Electrical apparatus for use in the presence of combustible dust Inspection and maintenance of electrical installations in hazardous areas (other than mines) |
BS EN 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust Selection and installation |
UNE-EN 1127-1:2012 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
EN 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation |
EN 61241-17:2005 | Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines) |
12/30270980 DC : 0 | BS EN 1127-2 - EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING |
I.S. EN 61241-14:2004 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 14: SELECTION AND INSTALLATION |
I.S. EN 1127-1:2011 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
DIN EN 1127-1:2011-10 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
BIS IS/IEC 60079-1 : 2007 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' |
02/204779 DC : DRAFT JULY 2002 | IEC 61241-17 ED.1 - ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES) |
CSA C22.4 No. 1 : 2009(R2018) | OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE |
I.S. EN 61241-17:2005 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES) |
BS EN 1127-1:2019 | Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology |
EEMUA 186 : 2016 | A PRACTITIONER'S HANDBOOK FOR POTENTIALLY EXPLOSIVE ATMOSPHERES |
IEC 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation |
IEC 61241-17:2005 | Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines) |
CSA C22.4 PACKAGE : 2009 | CONSISTS OF C22.4 NO. 1-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE AND C22.4 NO. 2-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE - SAFETY MANAGEMENT SYSTEM REQUIREMENTS |
UNI EN 1127-1 : 2011 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
02/205211 DC : DRAFT JULY 2002 | IEC 61241-14 ED.1 - ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 14: SELECTION AND INSTALLATION |
11/30247086 DC : 0 | BS EN 60079-1 ED. 7.0 - EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D" |
PREN 1127-2 : DRAFT 2012 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING |
BS EN 1127-1:2011 | Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology |
EN 1127-1:2011 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
IEC 61241-0:2004 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
IEC 61241-11:2005 | Electrical apparatus for use in the presence of combustible dust - Part 11: Protection by intrinsic safety 'iD' |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 61960-1:2000 | Secondary lithium cells and batteries for portable applications - Part 1: Secondary lithium cells |
IEC 61241-1:2004 | Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD" |
IEC 60691:2015 | Thermal-links - Requirements and application guide |
IEC 60086-1:2015 | Primary batteries - Part 1: General |
ISO 62:2008 | Plastics Determination of water absorption |
IEC 62326-4-1:1996 | Printed boards - Part 4: Rigid multilayer printed boards with interlayer connections - Sectional specification - Section 1: Capability detail specification - Performance levels A, B and C |
UL 248-1 : 3 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS |
IEC 61150:1992 | Alkaline secondary cells and batteries - Sealed nickel-cadmium rechargeable monobloc batteries in button cell design |
IEC 61436:1998 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-metal hydride rechargeable single cells |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60285:1993+AMD1:1995+AMD2:1998 CSV | Alkaline secondary cells and batteries - Sealed nickel-cadmium cylindrical rechargeable single cells |
IEC 60622:2002 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.