FOREWORD
1 Scope
2 Normative references
3 Definitions
4 Pressurization principle
   4.1 Protective gas
   4.2 Automatic disconnection
   4.3 Cleaning
   4.4 Discharge of protective gas
5 General constructional requirements
   5.1 Electrical performance of apparatus
   5.2 Mechanical strength
   5.3 Apertures
   5.4 Electrical connections to enclosures
   5.5 Doors and covers
6 Temperature limits
7 Safety provisions and safety devices (except for static
   pressurization)
   7.1 General
   7.2 Pressure- or flow-activated devices
   7.3 Electrical supply
   7.4 Switching off electrical supply
   7.5 Failure of pressurization
   7.6 Level of overpressure
   7.7 Possible sources of ignition
   7.8 Enclosed components
   7.9 Separate enclosures
8 Safety provisions and safety devices for static pressurization
9 Supply of protective gas
   9.1 Type of gas
   9.2 Second source of supply
   9.3 Temperature
10 Verification and tests
   10.1 General
   10.2 Type verification and tests
   10.3 Overpressure test
   10.4 Minimum overpressure test
   10.5 Leakage test
   10.6 Impact test
   10.7 Routine tests
11 Marking
   11.1 Pressurized enclosure
   11.2 Additional marking
   11.3 Pressurized enclosures protected by static pressurization
   11.4 Any other marking required
Annex A (normative) Ducts for protective gas supply
Annex B (normative) Installation requirements for pressurization

Gives requirements on the design, construction, testing and marking of electrical apparatus for use in combustible dust atmospheres in which a protective gas (air or inert gas), maintained at a pressure above that of the external atmosphere, is used to prevent the entry of dust which might otherwise lead to the formation of a combustible mixture within enclosures which do not contain a source of combustible dust.

Committee
TC 31
DevelopmentNote
Also numbered as BS IEC 61241-4. (09/2001) Stability Date: 2014. (10/2012)
DocumentType
Standard
Pages
22
PublisherName
International Electrotechnical Committee
Status
Superseded

UNE-EN 60079-17:2014 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
BS EN 60079-17:2014 Explosive atmospheres Electrical installations inspection and maintenance
I.S. EN 60079-0:2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011 (MOD))
BS EN 61241-17:2005 Electrical apparatus for use in the presence of combustible dust Inspection and maintenance of electrical installations in hazardous areas (other than mines)
12/30270980 DC : 0 BS EN 1127-2 - EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING
CSA C22.2 No. 60079.0 : 2015 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
BS EN 60079-19 : 2011 EXPLOSIVE ATMOSPHERES - PART 19: EQUIPMENT REPAIR, OVERHAUL AND RECLAMATION
BS EN 1127-1:2019 Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology
EN 60079-19:2011/A1:2015 EXPLOSIVE ATMOSPHERES - PART 19: EQUIPMENT REPAIR, OVERHAUL AND RECLAMATION (IEC 60079-19:2010)
UNE-EN 1127-1:2012 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology
EN 61241-17:2005 Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
NF EN 60079-19 : 2011 AMD 1 2015 EXPLOSIVE ATMOSPHERES - PART 19: EQUIPMENT REPAIR, OVERHAUL AND RECLAMATION
BS EN 1127-1:2011 Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology
09/30206527 DC : 0 BS EN 60079-0 ED 6.0 - EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
BIS IS/IEC 60079-0 : 2011 EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
DIN EN 1127-1:2011-10 EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY
EN 60079-14:2014/AC:2016 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016)
CSA C22.4 No. 1 : 2009(R2018) OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE
CEI EN 60079-17 : 2015 EXPLOSIVE ATMOSPHERES - PART 17: ELECTRICAL INSTALLATIONS INSPECTION AND MAINTENANCE
BS IEC 61241-4:2001 Electrical apparatus for use in the presence of combustible dust Type of protection \'pD\'
I.S. EN 60079-17:2014 EXPLOSIVE ATMOSPHERES - PART 17: ELECTRICAL INSTALLATIONS INSPECTION AND MAINTENANCE
I.S. EN 1127-1:2011 EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY
EEMUA 186 : 2016 A PRACTITIONER'S HANDBOOK FOR POTENTIALLY EXPLOSIVE ATMOSPHERES
UNE-EN 60079-14:2016 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
IEC 61241-17:2005 Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
C22.10-10 Québec Construction Code, Chapter V - Electricity Canadian Electrical Code, Part I (Twenty-first Edition) with Québec Amendments
CSA C22.4 PACKAGE : 2009 CONSISTS OF C22.4 NO. 1-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE AND C22.4 NO. 2-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE - SAFETY MANAGEMENT SYSTEM REQUIREMENTS
12/30268608 DC : 0 BS EN 60079-17/ED 5 - EXPLOSIVE ATMOSPHERES - PART 17: ELECTRICAL INSTALLATIONS INSPECTION AND MAINTENANCE
I.S. EN 61241-17:2005 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES)
UNE-EN 60079-0:2013 Explosive atmospheres - Part 0: Equipment - General requirements
05/30134569 DC : DRAFT JUN 2005 IEC 60079-0. ED. 5.0 - ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
IEC 60079-19:2010+AMD1:2015 CSV Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
BIS IS/IEC 60079-1 : 2007 EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D'
I.S. EN 60079-14:2014 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
11/30247086 DC : 0 BS EN 60079-1 ED. 7.0 - EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D"
UNI EN 1127-1 : 2011 EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY
PREN 1127-2 : DRAFT 2012 EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING
BS EN 60079-0 : 2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
UNE-EN 60079-19:2011 Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
12/30269297 DC : 0 BS EN 60079-14/ED 5 - EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
13/30286778 DC : 0 BS EN 60079-1 - EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D'
EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
EN 60079-17:2014 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
EN 1127-1:2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology

IEC 61241-1-1:1999 Electrical apparatus for use in the presence of combustible dust - Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus
IEC 61241-3:1997 Electrical apparatus for use in the presence of combustible dust - Part 3: Classification of areas where combustible dust are or may be present
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
IEC 61241-2-3:1994 Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 3: Method for determining minimum ignition energy of dust/air mixtures
IEC 61241-1-2:1999 Electrical apparatus for use in the presence of combustible dust - Part 1-2: Electrical apparatus protected by enclosures and surface temperature limitation - Selection, installation and maintenance
IEC 61241-2-1:1994 Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 1: Methods for determining the minimum ignition temperatures of dust

View more information
£140.72
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.