• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 61347-2-4:2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Lamp controlgear - Part 2-4: Particular requirements for d.c. supplied electronic ballasts for general lighting

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

19-05-2011

Language(s)

English - French, Spanish, Castilian

Published date

13-10-2000

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
      7.1 Mandatory markings
      7.2 Information to be provided, if applicable
8 Protection against accidental contact with live
      parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Pulse voltages
15 Abnormal conditions
      15.1 Removal of lamp(s)
      15.2 Lamp fails to start (cathodes intact
             electrically)
16 Fault conditions
17 Construction
18 Creepage distances and clearances
19 Screws, current-carrying parts and connections
20 Resistance to heat, fire and tracking
21 Resistance to corrosion
Annex A (normative) Test to establish whether a conductive
                    part is a live part which may cause an
                    electric shock
Annex B (normative) Particular requirements for thermally
                    protected lamp controlgear
Annex C (normative) Particular requirements for electronic
                    lamp controlgear with means of
                    protection against overheating
Annex D (normative) Requirements for carrying out the heating
                    tests of thermally protected lamp
                    controlgear
Annex E (normative) Use of constant S other than 4 500 in tw
                    tests
Annex F (normative) Draught-proof enclosure
Annex G (normative) Explanation of the derivation of the
                    values of pulse voltages
Annex H (normative) tests
Table 1 - Pulse voltages

This part of IEC 61347 specifies particular safety requirements for d.c. supplied electronic ballasts intended for operation from transient and surge-free power sources, operated directly from batteries without charging equipment as used in leisure equipment, for example, caravans, etc.This first edition of IEC 61347-2-4, together with IEC 61347-1, cancels and replaces section three of the first edition of IEC 60924, published in 1990, and constitutes a minor revision.This standard shall be used in conjunction with IEC 61347-1. It was established on the basis of the first edition (2000) of that standard.

DevelopmentNote
Supersedes IEC 60924 (03/2001) Also numbered as BS EN 61347-2-4 (04/2001)
DocumentType
Standard
Pages
21
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

NF EN 60079-15 : 2010 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
IEC 60079-7:2015+AMD1:2017 CSV Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
EN IEC 60079-7:2015/A1:2018 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017)
11/30243697 DC : 0 BS IEC 62718 - RAILWAY APPLICATIONS - ROLLING STOCK - D.C. SUPPLIED ELECTRONIC BALLASTS FOR LIGHTING FLUORESCENT LAMPS
I.S. EN 60079-15:2010 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
CSA C22.2 No. 60079-15 : 2016 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
BIS IS/IEC 60079-15 : 2005 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION 'N' ELECTRICAL APPARATUS
CEI EN 60079-15 : 2012 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
EN 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
14/30278882 DC : 0 BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
I.S. EN 60079-7:2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
BS EN 60079-15:2010 Explosive atmospheres Equipment protection by type of protection \'n\'
UL 1993:5ED 2017-01 Self-Ballasted Lamps and Lamp Adapters
C22.2 NO. 1993-17 Self-ballasted lamps and lamp adapters (Trinational standard with NMX-J-578/1-ANCE and UL 1993)
BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
GOST R 52350.15 : 2005 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION "N" ELECTRICAL APPARATUS
UNE-EN 60079-7:2016 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
UNE-EN 60079-15:2013 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
07/30168628 DC : 0 BS EN 60079-15 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N"
08/30186575 DC : DRAFT JULY 2008 BS EN 60079-15 ED. 4 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N"

IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
IEC 60925:1989+AMD1:1996+AMD2:2001 CSV DC supplied electronic ballasts for tubular fluorescent lamps - Performance requirements

View more information
£37.53
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.