• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 61643-12:2008

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Low-voltage surge protective devices - Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

31-12-2021

Language(s)

English - French

Published date

13-11-2008

FOREWORD
0 Introduction
  0.1 General
  0.2 Keys to understanding the structure of this standard
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
  3.1 Terms and definitions
  3.2 List of abbreviations and acronyms used in this standard
4 Systems and equipment to be protected
  4.1 Low-voltage power distribution systems
  4.2 Characteristics of the equipment to be protected
5 Surge protective devices
  5.1 Basic functions of SPDs
  5.2 Additional requirements
  5.3 Classification of SPDs
  5.4 Characteristics of SPDs
  5.5 Additional information on characteristics of SPDs
6 Application of SPDs in low-voltage power distribution
  systems
  6.1 Installation and its effect on the protection given
      by SPDs
  6.2 Selection of SPD
  6.3 Characteristics of auxiliary devices
7 Risk analysis
Annex A (informative) Typical information given with
        inquiries and tenders and explanation of
        testing procedures
  A.1 Information given with inquiries
  A.2 Information given with tender
  A.3 Explanation of testing procedures used in IEC 61643-1
Annex B (informative) Examples of relationship between
        U[c] and the nominal voltage used in some systems
        and example of relationship between U[p] and U[c]
        for ZnO varistor
  B.1 Relationship between U[c] and the nominal voltage of
      the system
  B.2 Relationship between U[p] and U[c] for a ZnO varistor
Annex C (informative) Environment - Surge voltages in LV
        systems
  C.1 General
  C.2 Lightning overvoltages
  C.3 Switching overvoltages
Annex D (informative) Partial lightning current calculations
Annex E (informative) TOV in the low-voltage system due
        to faults between high-voltage systems and earth
  E.1 General
  E.2 Example of a TT system - Calculation of the possible
      temporary overvoltages
  E.3 Values of the temporary overvoltages according to
      IEC 60364-4-44
  E.4 Values of the temporary overvoltages for the US TN
      C-S system
Annex F (informative) Coordination rules and principles
  F.1 General
  F.2 Analytical studies: simple case of the coordination of
      two ZnO varistor based SPDs
  F.3 Analytical study: case of coordination between a
      gap-based SPD and a ZnO varistor based SPD
  F.4 Analytical study: general coordination of two SPDs
  F.5 Let-through energy (LTE) method
Annex G (informative) Examples of application
  G.1 Domestic application
  G.2 Industrial application
  G.3 Presence of a lightning protection system
Annex H (informative) Examples of application of the
        risk analysis
Annex I (informative) System stresses
  I.1 Lightning overvoltages and currents [4.1.1]
  I.2 Switching overvoltages [4.1.2]
  I.3 Temporary overvoltages U[TOV] [4.1.3]
Annex J (informative) Criteria for selection of SPDs
  J.1 U[T] temporary overvoltage characteristic [5.5.1.2]
  J.2 SPD failure modes [5.5.4]
Annex K (informative) Application of SPDs
  K.1 Location and protection given by SPDs [6.1]
  K.2 Selection of SPDs
Annex L (informative) Risk analysis
  L.1 Group A - Environmental
  L.2 Group B - Equipment and facilities
  L.3 Group C - Economics and service interruption
  L.4 Group D - Safety
  L.5 Group E - Cost of protection
Annex M (informative) Immunity vs. insulation withstand
Annex N (informative) Examples of SPD installation in power
        distribution boards in some countries
Annex O (informative) Coordination when equipment has
        both signalling and power terminals
Annex P (informative) Short circuit backup protection and
        surge withstand
  P.1 Introduction
  P.2 Information single shot 8/20 and 10/350 fuses withstand
  P.3 Fuse Influencing factors (reduction) for preconditioning
      and operating duty test
  P.4 Specific examples with estimated range of factors for
      reduction of single shot fuse withstand
Bibliography

IEC 61643-12:2008 describes the principles for selection, operation, location and coordination of SPDs to be connected to 50 Hz to 60 Hz a.c. and to d.c. power circuits and equipment rated up to 1 000 V r.m.s. or 1 500 V d.c. Specific change with respect to the previous edition is the incorporation of Amendment 1, which was not published separately due to the number of changes and pages.

Committee
TC 37/SC 37A
DevelopmentNote
To be used in conjunction with IEC 61643-1. (11/2008) Stability Date: 2015. (10/2012)
DocumentType
Standard
Pages
318
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

03/305096 DC : DRAFT MAR 2003 IEC 62305-2 - PROTECTION AGAINST LIGHTNING - PART 2: RISK MANAGEMENT
15/30259978 DC : 0 BS EN 62477-2 - SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 2: POWER ELECTRONIC CONVERTERS FROM 1000 V A.C. OR 1500 V D.C. UP TO 36 KV A.C. OR 54 KV D.C.
03/305097 DC : DRAFT MAR 2003 IEC 62305-3 - PROTECTION AGAINST LIGHTNING - PART 3: PHYSICAL DAMAGE TO STRUCTURES AND LIFE HAZARD
14/30316036 DC : 0 BS EN 61643-32 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC USE INCLUDING D.C. - PART 32: SELECTION AND APPLICATION PRINCIPLES - SPDS CONNECTED TO PHOTOVOLTAIC INSTALLATIONS
IEC TR 62066:2002 Surge overvoltages and surge protection in low-voltage a.c. power systems - General basic information
UNE-EN 61400-24:2011 Wind turbines - Part 24: Lightning protection
S.R. HD 60364-5-534:2016 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - ISOLATION, SWITCHING AND CONTROL - CLAUSE 534: DEVICES FOR PROTECTION AGAINST TRANSIENT OVERVOLTAGES
BS EN 61000-4-5:2014 Electromagnetic compatibility (EMC) Testing and measurement techniques. Surge immunity test
BS EN 61400-24:2010 Wind turbines Lightning protection
IEC TR 61400-24:2002 Wind turbine generator systems - Part 24: Lightning protection
S.R. CLC/TS 50539-22:2010 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 22: SELECTION AND APPLICATION PRINCIPLES - WIND TURBINE APPLICATIONS
BS EN 61643-21 : 2001 LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS
S.R. CLC/TS 61643-22:2016 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 22: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - SELECTION AND APPLICATION PRINCIPLES
I.S. EN 61000-4-5:2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST
UTEC 17 100-2 : 2005 PROTECTION AGAINST LIGHTNING - PART 2: RISK MANAGEMENT
NFPA 780 : 2017 INSTALLATION OF LIGHTNING PROTECTION SYSTEMS
08/30177777 DC : DRAFT FEB 2008 BS EN 62548 - INSTALLATION AND SAFETY REQUIREMENTS FOR PHOTOVOLTAIC (PV) GENERATORS
PD IEC/TR 61439-0:2013 Low-voltage switchgear and controlgear assemblies Guidance to specifying assemblies
13/30238229 DC : 0 BS EN 62052-31 - ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TEST AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS
BS EN 62477-1 : 2012 SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 1: GENERAL (IEC 62477-1:2012)
14/30244780 DC : 0 BS ISO 19859 - GAS TURBINE APPLICATIONS - REQUIREMENTS FOR POWER GENERATION
EN 61800-5-1:2007/A1:2017 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-1: SAFETY REQUIREMENTS - ELECTRICAL, THERMAL AND ENERGY (IEC 61800-5-1:2007/A1:2016)
EN 62052-31:2016 Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests
CLC/TS 61643-22:2016 Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles
EN 62305-4:2011/AC:2016 PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010)
CLC/TS 50544:2010 Low voltage d.c. surge protective device for traction systems - Selection and application rules for surge arresters
HD 60364-5-534:2016 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages
EN 61000-4-5:2014/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST (IEC 61000-4-5:2014/A1:2017)
HD 60364-5-54:2011/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS
IEC TR 60664-2-2:2002 Insulation coordination for equipment within low-voltage systems - Part 2-2: Interface considerations - Application guide
PD CLC/TS 61643-22:2016 Low-voltage surge protective devices Surge protective devices connected to telecommunications and signalling networks. Selection and application principles
15/30324832 DC BS EN 62305-4. Protection against lightning. Part 4. Electrical and electronic systems within structures
PD IEC/TR 61400-24:2002 Wind turbine generator systems Lightning protection
CSA IEC 61400-24 : 2012 : R2017 WIND TURBINES - PART 24: LIGHTNING PROTECTION
DD IEC TS 62257-5 : DRAFT 2005 RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 5: PROTECTION AGAINST ELECTRICAL HAZARDS
PD IEC/TR 62066:2002 Surge overvoltages and surge protection in low-voltage a.c. power systems. General basic information
S.R. CLC/TS 50544:2010 LOW VOLTAGE D.C. SURGE PROTECTIVE DEVICE FOR TRACTION SYSTEMS - SELECTION AND APPLICATION RULES FOR SURGE ARRESTERS
IEC 61643-32:2017 Low-voltage surge protective devices - Part 32: Surge protective devices connected to the d.c. side of photovoltaic installations - Selection and application principles
CLC/TS 50539-22:2010 Low-voltage surge protective devices - Surge protective devices for specific application including d.c. - Part 22: Selection and application principles - Wind turbine applications
IEC 61643-11:2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
BIS IS/IEC 61400-24 : 2010 WIND TURBINES - PART 24: LIGHTNING PROTECTION
UTEC 15 443 : 2004 PROTECTION OF LOW-VOLTAGE ELECTRICAL INSTALLATIONS AGAINST OVER VOLTAGES OF ATMOSPHERIC DISCHARGES AND SWITCHING - SELECTION AND ERECTION OF SURGE PROTECTIVE DEVICES
CEI EN 62305-4 : 2013 PROTECTION CONTRE LA FOUDRE - PARTIE 4: RESEAUX DE PUISSANCE ET DE COMMUNICATION DANS LES STRUCTURES
IEC 61643-22:2015 Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
I.S. EN 61800-5-1:2007 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-1: SAFETY REQUIREMENTS - ELECTRICAL, THERMAL AND ENERGY
ISO 19859:2016 Gas turbine applications Requirements for power generation
VDI 3819 Blatt 2:2013-07 Fire protection building services - Functions and correlations
07/30174641 DC : DRAFT DEC 2007 BS EN 62305-3 - PROTECTION AGAINST LIGHTNING - PART 3: PHYSICAL DAMAGE TO STRUCTURES AND LIFE HAZARD
IEC TR 61439-0:2013 Low-voltage switchgear and controlgear assemblies - Part 0: Guidance to specifying assemblies
DD CLC/TS 50544:2010 Low voltage d.c. surge protective device for traction systems. Selection and application rules for surge arresters
03/318811 DC : DRAFT NOV 2003 IEC 62257-5 TS ED.1 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 5: SAFETY RULES - PROTECTION AGAINST ELECTRICAL HAZARDS
08/30176298 DC : DRAFT JAN 2008 BS EN 62477-1 - SAFETY REQUIREMENTS FOR POWER SEMICONDUCTOR CONVERTER SYSTEMS - PART 1: GENERAL
04/30123989 DC : DRAFT OCT 2004 IEC 61643-11 - SURGE PROTECTION DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - PART 11: PERFORMANCE REQUIREMENTS AND TESTING METHODS
09/30210369 DC : DRAFT SEP 2009 IEC 61643-11 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - PERFORMANCE REQUIREMENTS AND TESTING METHODS
BS EN 62305-4:2011 Protection against lightning Electrical and electronic systems within structures
UNE-EN 61000-4-5:2015 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
CEI EN 61643-11 : 2014 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TEST METHODS
I.S. EN 61643-11:2012 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TESTS METHODS
I.S. CLC TS 61643-22:2006 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 22: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - SELECTION AND APPLICATION PRINCIPLES
I.S. EN 62305-4:2011 PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES
CSA C61400-24 : 2007 WIND TURBINE GENERATOR SYSTEMS - PART 24: LIGHTNING PROTECTION
S.R. CLC/TS 61643-12:2009 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES
IEC 60204-1:2016 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC TS 62257-7-1:2010 Recommendations for small renewable energy and hybrid systems for rural electrification - Part 7-1: Generators - Photovoltaic generators
IEC 61643-1:2005 Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests
IEEE 2030.1.1-2015 IEEE Standard Technical Specifications of a DC Quick Charger for Use with Electric Vehicles
IEEE C62.72-2007 IEEE Guide for the Application of Surge Protective Devices for Low Voltage (1000 Volts or Less) AC Power Circuits
04/30119272 DC : DRAFT SEP 2004 IEC TS 62257-7-1 - RECOMMENDATION FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 7-1: GENERATORS - PHOTOVOLTAIC ARRAYS
DD CLC/TS 61643-12:2009 Low-voltage surge protective devices Surge protective devices connected to low-voltage power distribution systems. Selection and application principles
BS EN 61800-5-1:2007 Adjustable speed electrical power drive systems Safety requirements. Electrical, thermal and energy
UNE-EN 62305-4:2011 Protection against lightning -- Part 4: Electrical and electronic systems within structures
04/30116083 DC : DRAFT JUL 2004 IEC 62305-5 - PROTECTION AGAINST LIGHTNING - PART 5: SERVICES
03/305095 DC : DRAFT MAR 2003 IEC 62305-4 - PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES
CEI EN 61400-24 : 2011 WIND TURBINES - PART 24: LIGHTNING PROTECTION
CLC/TS 50539-12:2013 Low-voltage surge protective devices - Surge protective devices for specific application including d.c. - Part 12: Selection and application principles - SPDs connected to photovoltaic installations
02/209270 DC : DRAFT OCT 2002 IEC 62305-3 - PROTECTION AGAINST LIGHTNING - PART 3: PHYSICAL DAMAGE TO STRUCTURES AND LIFE HAZARD
NF EN 62305-4 : 2012 PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES
IEC 62305-4:2010 Protection against lightning - Part 4: Electrical and electronic systems within structures
DD CLC/TS 50539-12:2010 Low-voltage surge protective devices. Surge protective devices for specific application including d.c. Selection and application principles. SPDs connected to photovoltaic installations
04/30124138 DC : DRAFT OCT 2004 IEC 60364-5-53 ED.4 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - ISOLATION, SWITCHING AND CONTROL
CEI CLC/TS 50539-12 : 2011 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 12: SELECTION AND APPLICATION PRINCIPLES - SPDS CONNECTED TO PHOTOVOLTAIC INSTALLATIONS
07/30174629 DC : DRAFT DEC 2007 BS EN 62305-1 - PROTECTION AGAINST LIGHTNING - PART 1: GENERAL PRINCIPLES
CEI CLC/TS 50544 : 2011 LOW VOLTAGE D.C. SURGE PROTECTIVE DEVICE FOR TRACTION SYSTEMS - SELECTION AND APPLICATION RULES FOR SURGE ARRESTERS
DD CLC/TS 61643-22:2006 Low-voltage surge protective devices Surge protective devices connected to telecommunications and signalling networks. Selection and application principles
07/30174637 DC : DRAFT DEC 2007 BS EN 62305-4 - PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES
I.S. EN 61400-24:2010 WIND TURBINES - PART 24: LIGHTNING PROTECTION
S.R. HD 60364-5-54:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS
I.S. HD 60364-5-534:2008 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - ISOLATION, SWITCHING AND CONTROL - CLAUSE 534: DEVICES FOR PROTECTION AGAINST OVERVOLTAGES
I.S. EN 61643-21:2001 LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS (IEC 61643-21:2000 (EQV) + CORRIGENDUM MAR. 2001 (EQV))
IEC 60364-5-54:2011 Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors
IEC 62052-31:2015 Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests
12/30266531 DC : 0 BS EN TS 62257-1 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 1: GENERAL INTRODUCTION TO RURAL ELECTRIFICATION
07/30169755 DC : 0 BS EN 60364-5-53 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING
IEC 62477-1:2012+AMD1:2016 CSV Safety requirements for power electronic converter systems and equipment - Part 1: General
14/30238347 DC : 0 BS EN 60204-1 ED 6.0 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS
UNE-HD 60364-5-534:2016 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages
BS ISO 19859:2016 Gas turbine applications. Requirements for power generation
PD CLC/TS 50539-12:2013 Low-voltage surge protective devices. Surge protective devices for specific application including d.c. Selection and application principles. SPDs connected to photovoltaic installations
DD CLC/TS 50539-22:2010 Low-voltage surge protective devices. Surge protective devices for specific application including d.c. Selection and application principles. Wind turbine applications
S.R. CLC/TS 50539-12:2013 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 12: SELECTION AND APPLICATION PRINCIPLES - SPDS CONNECTED TO PHOTOVOLTAIC INSTALLATIONS
CSA IEC 61400-24:2012 WIND TURBINES - PART 24: LIGHTNING PROTECTION
07/30169774 DC : 0 BS EN 60364-5-53 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING
BS EN 61643-11 : 2012 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TEST METHODS
I.S. EN 62477-1:2012 SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 1: GENERAL
09/30190333 DC : 0 BS EN 61400-24 - WIND TURBINES - PART 24: LIGHTNING PROTECTION
CEI CLC/TS 50539-22 : 2012 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 22: SELECTION AND APPLICATION PRINCIPLES - WIND TURBINE APPLICATIONS
I.S. HD 60364-5-54:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS
I.S. EN 62052-31:2016 ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS AND TESTS
IEC TS 62257-5:2015 Recommendations for renewable energy and hybrid systems for rural electrification - Part 5: Protection against electrical hazards
EN 62477-1:2012/A1:2017 SAFETY REQUIREMENTS FOR POWER ELECTRONIC CONVERTER SYSTEMS AND EQUIPMENT - PART 1: GENERAL (IEC 62477-1:2012/A1:2016)
IEC 61400-24:2010 Wind turbines - Part 24: Lightning protection
PD IEC/TS 62257-5:2015 Recommendations for renewable energy and hybrid systems for rural electrification Protection against electrical hazards
15/30322229 DC : 0 BS EN 61800-5-1:2007/AMD 1 - ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-1: SAFETY REQUIREMENTS - ELECTRICAL, THERMAL AND ENERGY
UNE-CLC/TS 61643-12:2012 Low-voltage surge protective devices -- Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles
EN 61643-21:2001/A2:2013 LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS (IEC 61643-21:2000/A2:2012)
EN 61400-24:2010 Wind turbines - Part 24: Lightning protection
CLC/TS 61643-12 : 2009 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES
UNE-HD 60364-5-54:2015 Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors

IEC 60038:2009 IEC standard voltages
IEC 60364-4-43:2008 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
IEEE C62.41-1991 IEEE Recommended Practice for Surge Voltages in Low-Voltage AC Power Circuits
IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules
IEC 62305-1:2010 Protection against lightning - Part 1: General principles
IEC 60999-1:1999 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)
IEC 61643-22:2015 Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles
IEC 61643-1:2005 Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
IEC TR 61000-5-6:2002 Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences
IEC 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations
IEC TR 62066:2002 Surge overvoltages and surge protection in low-voltage a.c. power systems - General basic information
IEC 62305-4:2010 Protection against lightning - Part 4: Electrical and electronic systems within structures
IEC 62305-2:2010 Protection against lightning - Part 2: Risk management
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60364-4-42:2010+AMD1:2014 CSV Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 62305-3:2010 Protection against lightning - Part 3: Physical damage to structures and life hazard

View more information
£375.25
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.