• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ISO 10916:2014

Current
Current

The latest, up-to-date edition.

Calculation of the impact of daylight utilization on the net and final energy demand for lighting
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

17-06-2014

ISO 10916:2014 defines the calculation methodology for determining the monthly and annual amount of usable daylight penetrating non-residential buildings through vertical facades and rooflights and the impact thereof on the energy demand for electric lighting. It can be used for existing buildings and the design of new and renovated buildings.

ISO 10916:2014 provides the overall lighting energy balance equation relating the installed power density of the electric lighting system with daylight supply and lighting controls (proof calculation method).

The determination of the installed power density is not in the scope of this method, neither are controls relating, for instance, to occupancy detection. Provided the determination of the installed power density and control parameters using external sources, the internal loads by lighting and the lighting energy demand itself can be calculated. The energy demand for lighting and internal loads by lighting can then be taken into account in the overall building energy balance calculations: heating; ventilation; climate regulation and control (including cooling and humidification); and heating the domestic hot-water supply of buildings.

For estimating the daylight supply and rating daylight-dependent artificial lighting control systems, a simple table-based calculation approach is provided. The simple method describes the division of a building into zones as required for daylight illumination-engineering purposes, as well as considerations on the way in which daylight supplied by vertical facade systems and rooflights is utilized and how daylight-dependent lighting control systems effect energy demand. Dynamic vertical facades with optional shading and light redirection properties are considered, i.e. allowing a separate optimization of facade solutions under direct insolation and under diffuse skies. For rooflighting systems standard, static solutions like shed rooflights and continuous rooflights are considered. The method is applicable for different latitudes and climates. For standard building zones (utilizations), operation times are provided.

For detailed computer-based analysis (comprehensive calculation), minimum requirements are specified.

To support overall building performance assessment, additional daylight performance indicators on the overall building level are provided.

DevelopmentNote
Supersedes ISO/DIS 10916. (06/2014)
DocumentType
Standard
Pages
63
ProductNote
This standard also refers to CIE S 017/E:2011.
PublisherName
International Organization for Standardization
Status
Current

Standards Relationship
BS ISO 10916:2014 Identical

I.S. EN 15193-1:2017 ENERGY PERFORMANCE OF BUILDINGS - ENERGY REQUIREMENTS FOR LIGHTING - PART 1: SPECIFICATIONS, MODULE M9
15/30263791 DC : 0 BS ISO 17772-1 - ENERGY PERFORMANCE OF BUILDINGS - INDOOR ENVIRONMENTAL QUALITY - PART 1: INDOOR ENVIRONMENTAL INPUT PARAMETERS FOR THE DESIGN AND ASSESSMENT OF ENERGY PERFORMANCE OF BUILDINGS
17/30334840 DC BS ISO 20086. Light and lighting. Energy performance of lighting in buildings
EN 15193-1:2017 Energy performance of buildings - Energy requirements for lighting - Part 1: Specifications, Module M9
DIN EN 15193-1:2017-10 Energy performance of buildings - Energy requirements for lighting - Part 1: Specifications, Module M9
BS EN 15193-1:2017 Energy performance of buildings. Energy requirements for lighting Specifications, Module M9

EN 15193:2007/AC:2010 ENERGY PERFORMANCE OF BUILDINGS - ENERGY REQUIREMENTS FOR LIGHTING
DIN V 18599-4:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 4: NET AND FINAL ENERGY DEMAND FOR LIGHTING
DIN V 18599-2:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 2: NET ENERGY DEMAND FOR HEATING AND COOLING OF BUILDING ZONES
DIN 5034-6:2007-02 Daylight in interiors - Part 6: Simplified determination of suitable dimensions for rooflights
DIN V 18599-10:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 10: BOUNDARY CONDITIONS OF USE, CLIMATIC DATA

View more information
£178.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.