ISO 4802-1:2016 specifies:

a) a method for determining the hydrolytic resistance of the interior surfaces of glass containers when subjected to attack by water at 121 °C ± 1 °C for 60 min ± 1 min. The resistance is measured by titration of a known aliquot portion of the extraction solution produced with hydrochloric acid solution, in which case the resistance is inversely proportional to the volume of acid required;

b) a classification of glass containers according to the hydrolytic resistance of the interior surfaces determined by the methods specified in ISO 4802-1:2016.

Committee
ISO/TC 76
DevelopmentNote
Supersedes ISO 4802 (04/2001) Supersedes ISO/DIS 4802-1. (06/2016)
DocumentType
Standard
Pages
13
PublisherName
International Organization for Standardization
Status
Superseded
SupersededBy
Supersedes

03/106304 DC : DRAFT APR 2003 BS ISO 11418-2 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 2: SCREW-NECK BOTTLES FOR SYRUPS
15/30314949 DC : 0 BS ISO 11418-2 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 2: SCREW-NECK GLASS BOTTLES FOR SYRUPS
15/30314886 DC : 0 BS ISO 11418-1 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 1: DROP-DISPENSING GLASS BOTTLES
03/106303 DC : DRAFT APR 2003 BS ISO 11418-1 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 1: DROP-DISPENSING BOTTLES
BS 7709-3:1993 Analysis of extract solutions of glass Method for determination of calcium oxide and magnesium oxide by flame atomic absorption spectrometry
BS 7709-5:1993 Analysis of extract solutions of glass Method for determination of iron (III) oxide by molecular absorption spectrometry and flame atomic absorption spectrometry
BS 7709-1:1993 Analysis of extract solutions of glass Method for determination of silicon dioxide by molecular absorption spectrometry
ISO 1135-1:1987 Transfusion equipment for medical use Part 1: Glass transfusion bottles, closures and caps
NF EN ISO 8362-1 : 2010 AMD 1 2016 INJECTION CONTAINERS AND ACCESSORIES - PART 1: INJECTION VIALS MADE OF GLASS TUBING
BS EN ISO 9187-1:2010 Injection equipment for medical use Ampoules for injectables
BS EN ISO 8362-1 : 2009 INJECTION CONTAINERS AND ACCESSORIES - PART 1: INJECTION VIALS MADE OF GLASS TUBING (ISO 8362-1:2009)
DIN ISO 11040-1:2017-07 PREFILLED SYRINGES - PART 1: GLASS CYLINDERS FOR DENTAL LOCAL ANAESTHETIC CARTRIDGES (ISO 11040-1:2015)
EN ISO 8362-1:2009/A1:2015 INJECTION CONTAINERS AND ACCESSORIES - PART 1: INJECTION VIALS MADE OF GLASS TUBING (ISO 8362-1:2009/AMD 1:2015)
03/106306 DC : DRAFT APR 2003 BS ISO 11418-4 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 4: TABLET BOTTLES
DIN ISO 11040-1:1993-07 PREFILLED SYRINGES - PART 1: GLASS CYLINDERS FOR DENTAL LOCAL ANAESTHETIC CARTRIDGES (ISO 11040-1:2015)
BS ISO 11418-1:2016 Containers and accessories for pharmaceutical preparations Drop-dispensing glass bottles
BS ISO 11040-1:2015 Prefilled syringes Glass cylinders for dental local anaesthetic cartridges
DIN ISO 11040-4 E : 2017 PREFILLED SYRINGES - PART 4: GLASS BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING (ISO 11040-4:2015)
15/30314850 DC : 0 BS ISO 11418-7 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 7: SCREW-NECK VIALS MADE OF GLASS TUBING FOR LIQUID DOSAGE FORMS
BS ISO 11040-4:2015 Prefilled syringes Glass barrels for injectables and sterilized subassembled syringes ready for filling
BS 7709-6:1993 Analysis of extract solutions of glass Method for determination of boron (III) oxide by molecular absorption spectrometry
ISO 11040-1:2015 Prefilled syringes Part 1: Glass cylinders for dental local anaesthetic cartridges
ISO 8362-1:2009 Injection containers and accessories Part 1: Injection vials made of glass tubing
I.S. EN ISO 8536-1:2011 INFUSION EQUIPMENT FOR MEDICAL USE - PART 1: INFUSION GLASS BOTTLES (ISO 8536-1:2011)
I.S. EN ISO 9187-1:2010 INJECTION EQUIPMENT FOR MEDICAL USE - PART 1: AMPOULES FOR INJECTABLES
I.S. EN ISO 8362-4:2011 INJECTION CONTAINERS AND ACCESSORIES - PART 4: INJECTION VIALS MADE OF MOULDED GLASS (ISO 8362-4:2011)
ISO 7348:1992 Glass containers Manufacture Vocabulary
BS ISO 7348:1992 Glass containers. Manufacture. Vocabulary
ISO 11418-1:2016 Containers and accessories for pharmaceutical preparations — Part 1: Drop-dispensing glass bottles
13/30273499 DC : 0 BS ISO 11040-4 - PREFILLED SYRINGES - PART 4: GLASS BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING
ISO 11418-3:2016 Containers and accessories for pharmaceutical preparations — Part 3: Screw-neck glass bottles (veral) for solid and liquid dosage forms
BS ISO 11418-3 : 2016 CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 3: SCREW-NECK GLASS BOTTLES (VERAL) FOR SOLID AND LIQUID DOSAGE FORMS
BS ISO 11418-4:2005 Containers and accessories for pharmaceutical preparations Tablet glass bottles
ISO 11418-7:2016 Containers and accessories for pharmaceutical preparations Part 7: Screw-neck vials made of glass tubing for liquid dosage forms
BS 7709-4:1993 Analysis of extract solutions of glass Method for determination of aluminium oxide by molecular absorption spectrometry
DIN EN ISO 8362-1:2016-06 INJECTION CONTAINERS AND ACCESSORIES - PART 1: INJECTION VIALS MADE OF GLASS TUBING (ISO 8362-1:2009 + AMD 1:2015)
ISO 11418-2:2016 Containers and accessories for pharmaceutical preparations — Part 2: Screw-neck glass bottles for syrups
UNE-EN ISO 8362-4:2012 Injection containers and accessories - Part 4: Injection vials made of moulded glass (ISO 8362-4:2011)
ISO 9187-1:2010 Injection equipment for medical use Part 1: Ampoules for injectables
UNI EN ISO 9187-1 : 2010 INJECTION EQUIPMENT FOR MEDICAL USE - PART 1: AMPOULES FOR INJECTABLES
UNI EN ISO 8536-1 : 2011 INFUSION EQUIPMENT FOR MEDICAL USE - PART 1: INFUSION GLASS BOTTLES
UNI EN ISO 8362-4 : 2011 INJECTION CONTAINERS AND ACCESSORIES - PART 4: INJECTION VIALS MADE OF MOULDED GLASS
BS ISO 11418-7:2016 Containers and accessories for pharmaceutical preparations Screw-neck vials made of glass tubing for liquid dosage forms
ISO 11418-4:2005 Containers and accessories for pharmaceutical preparations — Part 4: Tablet glass bottles
DIN ISO 11040-1 E : 2017 PREFILLED SYRINGES - PART 1: GLASS CYLINDERS FOR DENTAL LOCAL ANAESTHETIC CARTRIDGES (ISO 11040-1:2015)
03/106305 DC : DRAFT APR 2003 BS ISO 11418-3 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 3: SCREW-NECK BOTTLES (VERAL) FOR SOLID AND LIQUID DOSAGE FORMS
BS 7709-2:1993 Analysis of extract solutions of glass Method for determination of sodium oxide and potassium oxide by flame spectrometric methods
ISO 12775:1997 Guidelines on types of glass of normal bulk-production composition and their test methods
DIN EN ISO 9187-1:2011-01 Injection equipment for medical use - Part 1: Ampoules for injectables (ISO 9187-1:2010)
ISO 11040-4:2015 Prefilled syringes Part 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling
DIN EN ISO 8536-1:2011-12 Infusion equipment for medical use - Part 1: Infusion glass bottles (ISO 8536-1:2011)
DIN EN ISO 8362-4:2011-12 Injection containers and accessories - Part 4: Injection vials made of moulded glass (ISO 8362-4:2011)
UNE-EN ISO 9187-1:2011 Injection equipment for medical use - Part 1: Ampoules for injectables (ISO 9187-1:2010)
BS EN 28362-4:1993 Injection containers for injectables and accessories Injection vials made of moulded glass
UNE-EN ISO 8536-1:2012 Infusion equipment for medical use - Part 1: Infusion glass bottles (ISO 8536-1:2011)
BS EN ISO 8536-1:2011 Infusion equipment for medical use Infusion glass bottles
BS EN ISO 8362-4:2011 Injection containers and accessories Injection vials made of moulded glass
ISO 8536-1:2011 Infusion equipment for medical use Part 1: Infusion glass bottles
EN ISO 8362-4:2011 Injection containers and accessories - Part 4: Injection vials made of moulded glass (ISO 8362-4:2011)
EN ISO 9187-1:2010 Injection equipment for medical use - Part 1: Ampoules for injectables (ISO 9187-1:2010)
EN ISO 8536-1:2011 Infusion equipment for medical use - Part 1: Infusion glass bottles (ISO 8536-1:2011)
14/30310712 DC : 0 BS ISO 11040-1 - PREFILLED SYRINGES - PART 1: GLASS CYLINDERS FOR DENTAL LOCAL ANAESTHETIC CARTRIDGES
15/30314952 DC : 0 BS ISO 11418-3 - CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 3: SCREW-NECK GLASS BOTTLES (VERAL) FOR SOLID AND LIQUID DOSAGE FORMS
BS ISO 12775:1997 Guidelines on types of glass of normal bulk-production composition and their test methods
DIN ISO 11040-4:2007-10 PREFILLED SYRINGES - PART 4: GLASS BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING (ISO 11040-4:2015)
BS 3473-4.2:1989 Chemical resistance of glass used in the production of laboratory glassware. Methods for determination of hydrolytic resistance ofthe interior surfaces of glass containers Determination by flame photometry and classification
BS ISO 11418-2 : 2016 CONTAINERS AND ACCESSORIES FOR PHARMACEUTICAL PREPARATIONS - PART 2: SCREW-NECK GLASS BOTTLES FOR SYRUPS
ISO 13926-1:2004 Pen systems Part 1: Glass cylinders for pen-injectors for medical use
I.S. EN ISO 8362-1:2009 INJECTION CONTAINERS AND ACCESSORIES - PART 1: INJECTION VIALS MADE OF GLASS TUBING (ISO 8362-1:2009)
DIN ISO 11040-4:2017-07 PREFILLED SYRINGES - PART 4: GLASS BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING (ISO 11040-4:2015)
UNE-EN ISO 8362-1:2010 Injection containers and accessories - Part 1: Injection vials made of glass tubing (ISO 8362-1:2009)

ISO 11040-4:2015 Prefilled syringes Part 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling
ISO 13926-1:2004 Pen systems Part 1: Glass cylinders for pen-injectors for medical use
ISO 385:2005 Laboratory glassware Burettes
ISO 720:1985 Glass Hydrolytic resistance of glass grains at 121 degrees C Method of test and classification
ISO 3585:1998 Borosilicate glass 3.3 Properties
ISO 648:2008 Laboratory glassware — Single-volume pipettes
ISO 3819:2015 Laboratory glassware Beakers
ISO 1773:1997 Laboratory glassware Narrow-necked boiling flasks
ISO 8362-4:2011 Injection containers and accessories Part 4: Injection vials made of moulded glass
ISO 8362-1:2009 Injection containers and accessories Part 1: Injection vials made of glass tubing
ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
ISO 11418-1:2016 Containers and accessories for pharmaceutical preparations — Part 1: Drop-dispensing glass bottles
ISO 11418-4:2005 Containers and accessories for pharmaceutical preparations — Part 4: Tablet glass bottles
ISO 11040-1:2015 Prefilled syringes Part 1: Glass cylinders for dental local anaesthetic cartridges
ISO 719:1985 Glass Hydrolytic resistance of glass grains at 98 degrees C Method of test and classification
ISO 9187-1:2010 Injection equipment for medical use Part 1: Ampoules for injectables
ISO 11418-7:2016 Containers and accessories for pharmaceutical preparations Part 7: Screw-neck vials made of glass tubing for liquid dosage forms
ISO 8536-1:2011 Infusion equipment for medical use Part 1: Infusion glass bottles

View more information
£58.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.