ISO 4965-1:2012

Current

Current

The latest, up-to-date edition.

Metallic materials — Dynamic force calibration for uniaxial fatigue testing — Part 1: Testing systems

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

French, English

Published date

06-07-2012

ISO 4965-1:2012 describes two methods for determining the relationship between the dynamic force range applied to a test-piece in a uniaxial, sinusoidal, constant amplitude test and the force range indicated by the testing system.

These methods are applicable to dynamic testing systems operating away from system resonant frequencies and are relevant to testing systems where the dynamic force measurement errors are either unknown or where they are expected to exceed 1 % of the applied force range.

The dynamic force measurement errors are determined by comparison of the peak forces indicated by the dynamic testing system with those measured by the strain gauged dynamic calibration device (DCD). This DCD has previously undergone static calibration against the testing system indicator.

For Method A (Replica test-piece method), the dynamic calibration is applicable over the validated range of frequencies for that type of test-piece only. A frequency-dependent correction factor is applicable for the correction of dynamic force measurement errors of up to 10 % of dynamic force range. By using such a correction factor, the actual test specimen dynamic force measurement error will be reduced to less than 1 % of the dynamic force range.

For Method B (Compliance envelope method), the dynamic calibration is applicable over the range of test frequencies validated for test-pieces whose compliance lies between those of the two DCDs. No correction factor is applicable, as Method B does not permit dynamic force measurement errors above 1 % of the dynamic force range.

Committee
ISO/TC 164/SC 4
DevelopmentNote
Supersedes ISO/DIS 4965-1. Together with ISO 4965-2, supersedes ISO 4965. (07/2012)
DocumentType
Standard
Pages
14
PublisherName
International Organization for Standardization
Status
Current
Supersedes

Standards Relationship
NF ISO 4965-1:2022 Identical
BS ISO 4965-1:2012 Identical
NEN ISO 4965-1 : 2012 Identical

17/30352962 DC : 0 BS EN ISO 15630-1 - STEEL FOR THE REINFORCEMENT AND PRESTRESSING OF CONCRETE - TEST METHODS - PART 1: REINFORCING BARS, WIRE ROD AND WIRE
ISO 12108:2012 Metallic materials Fatigue testing Fatigue crack growth method
ISO 12106:2017 Metallic materials — Fatigue testing — Axial-strain-controlled method
15/30319527 DC : DRAFT DEC 2015 BS ISO 18192-3 - IMPLANTS FOR SURGERY - WEAR OF TOTAL INTERVERTEBRAL SPINAL DISC PROSTHESES - PART 3: LOADING AND DISPLACEMENT PARAMETERS FOR IMPINGEMENT-WEAR TESTING AND CORRESPONDING ENVIRONMENTAL CONDITIONS FOR TEST OF LUMBAR PROSTHESES UNDER ADVERSE KINEMATIC CONDITIONS
BS ISO 1099:2017 Metallic materials. Fatigue testing. Axial force-controlled method
ISO 1099:2017 Metallic materials — Fatigue testing — Axial force-controlled method
15/30323943 DC : 0 BS ISO 12106 - METALLIC MATERIALS - FATIGUE TESTING - AXIAL-STRAIN-CONTROLLED METHOD
BS ISO 18192-3:2017 Implants for surgery. Wear of total intervertebral spinal disc prostheses Impingement-wear testing and corresponding environmental conditions for test of lumbar prostheses under adverse kinematic conditions
17/30352970 DC : 0 BS EN ISO 15630-3 - STEEL FOR THE REINFORCEMENT AND PRESTRESSING OF CONCRETE - TEST METHODS - PART 3: PRESTRESSING STEEL
17/30352966 DC : 0 BS EN ISO 15630-2 - STEEL FOR THE REINFORCEMENT AND PRESTRESSING OF CONCRETE - TEST METHODS - PART 2: WELDED FABRIC AND LATTICE GIRDER
BS ISO 12108:2012 Metallic materials. Fatigue testing. Fatigue crack growth method
17/30361445 DC : DRAFT SEP 2017 BS ISO 12108 - METALLIC MATERIALS - FATIGUE TESTING - FATIGUE CRACK GROWTH METHOD
ISO 7206-6:2013 Implants for surgery — Partial and total hip joint prostheses — Part 6: Endurance properties testing and performance requirements of neck region of stemmed femoral components
BS ISO 12106:2017 Metallic materials. Fatigue testing. Axial-strain-controlled method
BS ISO 7206-6:2013 Implants for surgery. Partial and total hip joint prostheses Endurance properties testing and performance requirements of neck region of stemmed femoral components
15/30328599 DC : 0 BS ISO 1099 - METALLIC MATERIALS - FATIGUE TESTING - AXIAL FORCE-CONTROLLED METHOD
ASTM F 2777 : 2016 : REDLINE Standard Test Method for Evaluating Knee Bearing (Tibial Insert) Endurance and Deformation Under High Flexion
ISO 18192-3:2017 Implants for surgery — Wear of total intervertebral spinal disc prostheses — Part 3: Impingement-wear testing and corresponding environmental conditions for test of lumbar prostheses under adverse kinematic conditions

ISO 7500-1:2015 Metallic materials Calibration and verification of static uniaxial testing machines Part 1: Tension/compression testing machines Calibration and verification of the force-measuring system
ISO 4965-2:2012 Metallic materials — Dynamic force calibration for uniaxial fatigue testing — Part 2: Dynamic calibration device (DCD) instrumentation

View more information
£88.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.