ISO 52016-1:2017 specifies calculation methods for the assessment of:

a) the (sensible) energy need for heating and cooling, based on hourly or monthly calculations;

b) the latent energy need for (de-)humidification, based on hourly or monthly calculations;

c) the internal temperature, based on hourly calculations;

d) the sensible heating and cooling load, based on hourly calculations;

e) the moisture and latent heat load for (de-)humidification, based on hourly calculations;

f) the design sensible heating or cooling load and design latent heat load using an hourly calculation interval;

g) the conditions of the supply air to provide the necessary humidification and dehumidification.

The calculation methods can be used for residential or non-residential buildings, or a part of it, referred to as "the building" or the "assessed object".

ISO 52016-1:2017 also contains specifications for the assessment of thermal zones in the building or in the part of a building. The calculations are performed per thermal zone. In the calculations, the thermal zones can be assumed to be thermally coupled or not.

The calculation methods have been developed for the calculation of the basic energy loads and needs, without interaction with specific technical building systems, and for the calculation of the system specific energy loads and needs, including the interaction with specific systems. The hourly calculation procedures can also be used as basis for calculations with more extensive system control options.

ISO 52016-1:2017 is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.

NOTE Table 1 in the Introduction shows the relative position of ISO 52016-1:2017 within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.

DevelopmentNote
Supersedes ISO/DIS 52016-1. (06/2017)
DocumentType
Standard
Pages
204
PublisherName
International Organization for Standardization
Status
Current
Supersedes

I.S. EN ISO 52017-1:2017 ENERGY PERFORMANCE OF BUILDINGS - SENSIBLE AND LATENT HEAT LOADS AND INTERNAL TEMPERATURES - PART 1: GENERIC CALCULATION PROCEDURES (ISO 52017-1:2017)
BS EN 15232-1:2017 Energy Performance of Buildings Impact of Building Automation, Controls and Building Management. Modules M10-4,5,6,7,8,9,10
PREN 17213 : DRAFT 2018 WINDOWS AND DOORS - ENVIRONMENTAL PRODUCT DECLARATIONS - PRODUCT CATEGORY RULES FOR WINDOWS AND PEDESTRIAN DOORSETS
DIN EN 16947-1:2016-01 (Draft) ENERGY PERFORMANCE OF BUILDINGS - BUILDING MANAGEMENT SYSTEM - PART 1: MODULE M10-12
PD CEN ISO/TR 52016-2:2017 Energy performance of buildings. Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Explanation and justification of ISO 52016-1 and ISO 52017-1
DIN EN 16947-1 E : 2017 ENERGY PERFORMANCE OF BUILDINGS - BUILDING MANAGEMENT SYSTEM - PART 1: MODULE M10-12
CEN ISO/TR 52000-2:2017 Energy performance of buildings - Overarching EPB assessment - Part 2: Explanation and justification of ISO 52000-1 (ISO/TR 52000-2:2017)
I.S. EN ISO 13370:2017 THERMAL PERFORMANCE OF BUILDINGS - HEAT TRANSFER VIA THE GROUND - CALCULATION METHODS (ISO 13370:2017)
I.S. EN 16798-5-1:2017 ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 5-1: CALCULATION METHODS FOR ENERGY REQUIREMENTS OF VENTILATION AND AIR CONDITIONING SYSTEMS (MODULES M5-6, M5-8, M6-5, M6-8, M7-5, M7-8) - METHOD 1: DISTRIBUTION AND GENERATION
I.S. EN ISO 52018-1:2017 ENERGY PERFORMANCE OF BUILDINGS - INDICATORS FOR PARTIAL EPB REQUIREMENTS RELATED TO THERMAL ENERGY BALANCE AND FABRIC FEATURES - PART 1: OVERVIEW OF OPTIONS (ISO 52018-1:2017)
CEN ISO/TR 52010-2:2017 Energy performance of buildings - External climatic conditions - Part 2: Explanation and justification of ISO 52010-1 (ISO/TR 52010-2:2017)
CEN ISO/TR 52016-2:2017 Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1 (ISO/TR 52016-2:2017)
S.R. CEN ISO/TR 52010-2:2017 ENERGY PERFORMANCE OF BUILDINGS - EXTERNAL CLIMATIC CONDITIONS - PART 2: EXPLANATION AND JUSTIFICATION OF ISO 52010-1 (ISO/TR 52010-2:2017)
S.R. CEN ISO/TR 52019-2:2017 ENERGY PERFORMANCE OF BUILDINGS - HYGROTHERMAL PERFORMANCE OF BUILDING COMPONENTS AND BUILDING ELEMENTS - PART 2: EXPLANATION AND JUSTIFICATION (ISO/TR 52019-2:2017)
PD CEN ISO/TR 52019-2:2017 Energy performance of buildings. Hygrothermal performance of building components and building elements Explanation and justification
CEI UNI EN 16247-2:2022 Energy audits Part 2: Buildings<br>
BS EN ISO 13370:2017 Thermal performance of buildings. Heat transfer via the ground. Calculation methods
S.R. CEN ISO/TR 52000-2:2017 ENERGY PERFORMANCE OF BUILDINGS - OVERARCHING EPB ASSESSMENT - PART 2: EXPLANATION AND JUSTIFICATION OF ISO 52000-1 (ISO/TR 52000-2:2017)
S.R. CEN ISO/TR 52016-2:2017 ENERGY PERFORMANCE OF BUILDINGS - ENERGY NEEDS FOR HEATING AND COOLING, INTERNAL TEMPERATURES AND SENSIBLE AND LATENT HEAT LOADS - PART 2: EXPLANATION AND JUSTIFICATION OF ISO 52016-1 AND ISO 52017-1 (ISO/TR 52016-2:2017)
BS EN ISO 52018-1:2017 Energy performance of buildings. Indicators for partial EPB requirements related to thermal energy balance and fabric features Overview of options
BS ISO 18566-3:2017 Building environment design. Design, test methods and control of hydronic radiant heating and cooling panel systems Design of ceiling mounted radiant panels
ISO 52017-1:2017 Energy performance of buildings — Sensible and latent heat loads and internal temperatures — Part 1: Generic calculation procedures
ISO/TR 52000-2:2017 Energy performance of buildings Overarching EPB assessment Part 2: Explanation and justification of ISO 52000-1
EN 15232-1:2017 Energy Performance of Buildings - Energy performance of buildings - Part 1: Impact of Building Automation, Controls and Building Management - Modules M10-4,5,6,7,8,9,10
ISO 52018-1:2017 Energy performance of buildings — Indicators for partial EPB requirements related to thermal energy balance and fabric features — Part 1: Overview of options
EN ISO 52010-1:2017 Energy performance of buildings - External climatic conditions - Part 1: Conversion of climatic data for energy calculations (ISO 52010-1:2017)
ISO/TR 52016-2:2017 Energy performance of buildings Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
ISO 18566-3:2017 Building environment design — Design, test methods and control of hydronic radiant heating and cooling panel systems — Part 3: Design of ceiling mounted radiant panels
PD CEN ISO/TR 52000-2:2017 Energy performance of buildings. Overarching EPB assessment Explanation and justification of ISO 52000-1
BS EN ISO 52010-1:2017 Energy performance of buildings. External climatic conditions Conversion of climatic data for energy calculations
18/30367193 DC : 0 BS EN 17213 - WINDOWS AND DOORS - ENVIRONMENTAL PRODUCT DECLARATIONS - PRODUCT CATEGORY RULES FOR WINDOWS AND PEDESTRIAN DOORSETS
I.S. EN 15232-1:2017 ENERGY PERFORMANCE OF BUILDINGS - ENERGY PERFORMANCE OF BUILDINGS - PART 1: IMPACT OF BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - MODULES M10-4, 5, 6, 7, 8, 9, 10
PD CEN ISO/TR 52010-2:2017 Energy performance of buildings. External climatic conditions Explanation and justification of ISO 52010-1
EN 16798-5-1:2017 Energy performance of buildings - Ventilation for buildings - Part 5-1: Calculation methods for energy requirements of ventilation and air conditioning systems (Modules M5-6, M5-8, M6-5, M6-8, M7-5, M7-8) - Method 1: Distribution and generation
I.S. EN ISO 52010-1:2017 ENERGY PERFORMANCE OF BUILDINGS - EXTERNAL CLIMATIC CONDITIONS - PART 1: CONVERSION OF CLIMATIC DATA FOR ENERGY CALCULATIONS (ISO 52010-1:2017)
EN 16947-1:2017 Energy Performance of Buildings - Building Management System - Part 1: Module M10-12
ISO/TR 52010-2:2017 Energy performance of buildings - External climatic conditions Part 2: Explanation and justification of ISO 52010-1
ISO/TR 52019-2:2017 Energy performance of buildings Hygrothermal performance of building components and building elements Part 2: Explanation and justification
BS EN ISO 52017-1:2017 Energy performance of buildings. Sensible and latent heat loads and internal temperatures Generic calculation procedures
I.S. EN 16798-5-2:2017 ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 5-2: CALCULATION METHODS FOR ENERGY REQUIREMENTS OF VENTILATION SYSTEMS (MODULES M5-6, M5-8, M6-5, M6-8, M7-5, M7-8) - METHOD 2: DISTRIBUTION AND GENERATION
BS EN 16947-1:2017 Energy Performance of Buildings. Building Management System Module M10-12
BS EN 16798-5-1:2017 Energy performance of buildings. Ventilation for buildings Calculation methods for energy requirements of ventilation and air conditioning systems (Modules M5-6, M5-8, M6-5, M6-8, M7-5, M7-8). Method 1: Distribution and generation
EN ISO 52018-1:2017 Energy performance of buildings - Indicators for partial EPB requirements related to thermal energy balance and fabric features - Part 1: Overview of options (ISO 52018-1:2017)
EN ISO 52017-1:2017 Energy performance of buildings - Sensible and latent heat loads and internal temperatures - Part 1: Generic calculation procedures (ISO 52017-1:2017)
EN ISO 13370:2017 Thermal performance of buildings - Heat transfer via the ground - Calculation methods (ISO 13370:2017)
CEN ISO/TR 52019-2:2017 Energy performance of buildings - Hygrothermal performance of building components and building elements - Part 2: Explanation and justification (ISO/TR 52019-2:2017)

ISO 13789:2017 Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method
CEN/TS 16629:2014 Energy Performance of Buildings - Detailed Technical Rules for the set of EPB-standards
ISO 13792:2012 Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling Simplified methods
EN 673:2011 Glass in building - Determination of thermal transmittance (U value) - Calculation method
CEN/TS 16628:2014 Energy Performance of Buildings - Basic Principles for the set of EPB standards
ISO 9488:1999 Solar energy Vocabulary
EN 410:2011 Glass in building - Determination of luminous and solar characteristics of glazing
ISO 52022-3:2017 Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 3: Detailed calculation method of the solar and daylight characteristics for solar protection devices combined with glazing
ISO 15927-4:2005 Hygrothermal performance of buildings — Calculation and presentation of climatic data — Part 4: Hourly data for assessing the annual energy use for heating and cooling
ISO 15099:2003 Thermal performance of windows, doors and shading devices — Detailed calculations
EN 15265:2007 Energy performance of buildings - Calculation of energy needs for space heating and cooling using dynamic methods - General criteria and validation procedures
ISO 52000-1:2017 Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures
ISO 52017-1:2017 Energy performance of buildings — Sensible and latent heat loads and internal temperatures — Part 1: Generic calculation procedures
ISO 15927-5:2004 Hygrothermal performance of buildings Calculation and presentation of climatic data Part 5: Data for design heat load for space heating
ISO 52010-1:2017 Energy performance of buildings — External climatic conditions — Part 1: Conversion of climatic data for energy calculations
ISO/TR 52016-2:2017 Energy performance of buildings Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
ISO/TR 52019-2:2017 Energy performance of buildings Hygrothermal performance of building components and building elements Part 2: Explanation and justification
ISO 9050:2003 Glass in building — Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors
ISO 13786:2017 Thermal performance of building components — Dynamic thermal characteristics — Calculation methods
ISO 13370:2017 Thermal performance of buildings — Heat transfer via the ground — Calculation methods
ISO/TR 52000-2:2017 Energy performance of buildings Overarching EPB assessment Part 2: Explanation and justification of ISO 52000-1
ISO 13791:2012 Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling General criteria and validation procedures
EN 14351-1:2006+A2:2016 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets
ISO 15927-2:2009 Hygrothermal performance of buildings Calculation and presentation of climatic data Part 2: Hourly data for design cooling load
EN 15255:2007 Energy performance of buildings - Sensible room cooling load calculation - General criteria and validation procedures
ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods
ISO 10077-1:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General
ISO 13790:2008 Energy performance of buildings Calculation of energy use for space heating and cooling
ASHRAE 140 : 2014 METHOD OF TEST FOR THE EVALUATION OF BUILDING ENERGY ANALYSIS COMPUTER PROGRAMS
ISO 7345:1987 Thermal insulation Physical quantities and definitions
PREN 12831-1 : DRAFT 2014 HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF THE DESIGN HEAT LOAD - PART 1: SPACE HEATING LOAD
ISO 10292:1994 Glass in building — Calculation of steady-state U values (thermal transmittance) of multiple glazing

View more information
£199.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.