1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - PROCEDURE FOR QUALIFICATION INSPECTION

Specifies the general requirements for nonestablished reliability (non-ER), established reliability (ER), accurate, wire-wound, fixed resistors that have a maximum resistance tolerance of 1 percent and a high degree of stability with respect to time under specified environmental conditions.

This specification covers the general requirements for nonestablished reliability (non-ER), established reliability (ER), accurate, wirewound, fixed resistors that have a maximum resistance tolerance of 1 percent and a high degree of stability with respect to time under specified environmental conditions. The resistors are capable for continuous full-load (or voltage) operation at any ambient temperature up to 125OC, and when derated, up to 145OC (see 6.5). They are not capable for application where the alternating current (ac) characteristics are of critical importance. ER resistors have life failure rates (FR) ranging from 1.0 percent to 0.001 percent per 1,000 hours (see 1.2.1.5). These FR are established at 60-percent confidence level on the basis of the life tests. The FR, identified by the appropriate symbol, is referred to operation at full rated voltage and temperature.

DevelopmentNote
Supersedes MIL R 39005 (03/2004)
DocumentType
Standard
Pages
78
PublisherName
US Military Specs/Standards/Handbooks
Status
Current
Supersedes

DSCC 09008 : A RESISTOR, FIXED, WIREWOUND, (ACCURATE), RADIAL LEADED, 0.1 WATT (RBR81)
MIL-STD-1580 Revision B:2003 DESTRUCTIVE PHYSICAL ANALYSIS FOR ELECTRONIC, ELECTROMAGNETIC, AND ELECTROMECHANICAL PARTS
DSCC 15002 : 0 RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.33 WATT (RBR53)
MIL-PRF-39005-4 Revision G:2008 RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR55
DSCC 14007 : 0 RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.25 WATT (RBR54)
MIL-PRF-39005-3 Revision F:2008 RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR54
MIL STD 11991 : A GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES
MIL-PRF-39005-10 Revision B:1997 RESISTORS, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY, AND ESTABLISHED RELIABILITY STYLE RER76
DSCC 15003 : 0 RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.15 WATT (RBR55)
MIL-PRF-39005-1 Revision F:2008 RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR52
MIL-PRF-39005-9 Revision C:2008 RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR75
MIL-HDBK-199 Revision D:2018 Resistors, Selection and Use of
MIL-DTL-39032 Revision E:2000 RESISTORS, PACKAGING OF
MIL-PRF-39005-8 Revision C:2008 RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR74
MIL-PRF-39005-5 Revision H:2008 RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR56
MIL-PRF-39005-11 Revision C:2008 RESISTOR, FIXED, WIRE WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR80 AND RBR81
MIL-PRF-39005-2 Revision F:2008 RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR53
NASA MSFC STD 3012 : 2012 ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL (EEE) PARTS MANAGEMENT AND CONTROL REQUIREMENTS FOR MSFC SPACE FLIGHT HARDWARE
DSCC 15004 : A RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.125 WATT (RBR71)
DSCC 16001 : 0 RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.125 WATT (RBR75)
MIL-PRF-39005-7 Revision D:2008 RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR57
DSCC 14006 : 0 RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.5 WATT (RBR52)
MIL R 93 : F RESISTORS, FIXED, WIRE-WOUND (ACCURATE), GENERAL SPECIFICATION FOR
MIL-PRF-39005-6 Revision F:2008 RESISTOR, FIXED, WIRE-WOUND (ACCURATE), NONESTABLISHED RELIABILITY AND ESTABLISHED RELIABILITY STYLE RBR71
DSCC 14008 : A RESISTOR, FIXED, WIREWOUND, (ACCURATE), 0.125 WATT (RBR56)

MIL-STD-202-211 Base Document:2015 METHOD 211, TERMINAL STRENGTH
MIL-STD-202-302 Base Document:2015 METHOD 302, INSULATION RESISTANCE
MIL-STD-202-304 Base Document:2015 METHOD 304, RESISTANCE-TEMPERATURE CHARACTERISTIC
MIL-STD-810 Revision G:2008 ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS
MIL-STD-202-210 Base Document:2015 METHOD 210, RESISTANCE TO SOLDERING HEAT
MIL-STD-1276 Revision H:2013 Leads for Electronic Component Parts
MIL-STD-202-303 Base Document:2015 METHOD 303, DC RESISTANCE
MIL-STD-202-107 Base Document:2015 METHOD 107, THERMAL SHOCK
MIL-STD-202-106 Base Document:2015 METHOD 106, MOISTURE RESISTANCE
MIL-STD-202-301 Base Document:2015 METHOD 301, DIELECTRIC WITHSTANDING VOLTAGE
MIL-STD-202-215 Base Document:2015 METHOD 215, RESISTANCE TO SOLVENTS
MIL-STD-790 Revision G:2011 ESTABLISHED RELIABILITY AND HIGH RELIABILITY QUALIFIED PRODUCTS LIST (QPL) SYSTEMS FOR ELECTRICAL, ELECTRONIC, AND FIBER OPTIC PARTS SPECIFICATIONS
MIL-STD-202-108 Base Document:2015 METHOD 108, LIFE (AT ELEVATED AMBIENT TEMPERATURE)
MIL-STD-202-105 Base Document:2015 METHOD 105, BAROMETRIC PRESSURE (REDUCED)
MIL-STD-202-208 Base Document:2015 METHOD 208, SOLDERABILITY
MIL-STD-202 Revision H:2015 ELECTRONIC AND ELECTRICAL COMPONENT PARTS
MIL-STD-1285 Revision D:2004 MARKING OF ELECTRICAL AND ELECTRONIC PARTS
EIA 557 : 2006 STATISTICAL PROCESS CONTROL SYSTEMS
MIL-STD-690 Revision D:2005 Failure Rate (FR) Sampling Plans and Procedures
MIL-STD-202-204 Base Document:2015 METHOD 204, VIBRATION, HIGH FREQUENCY
MIL-STD-202-213 Base Document:2015 METHOD 213, SHOCK (SPECIFIED PULSE)

View more information
£16.70
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.