MIL-PRF-85045 Revision G:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
05-11-2021
17-06-2014
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - QUALIFICATION OF MODIFIED DESIGN,
QUALIFICATION BY SIMILARITY FOR MM TO SM,
AND QUALIFICATION DUE TO PLANT RELOCATION
Specifies cables utilizing optical fibers for signal transmission.
This specification covers cables utilizing optical fibers for signal transmission.
DevelopmentNote |
Supersedes MIL C 85045 (E). (04/2009)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
MIL-STD-1678-2 Revision A:2013 | FIBER OPTIC CABLING SYSTEMS REQUIREMENTS AND MEASUREMENTS - PART 2: OPTICAL MEASUREMENTS (PART 2 OF 6 PARTS) |
MIL-STD-1678-6 Revision A:2016 | FIBER OPTIC CABLING SYSTEMS REQUIREMENTS AND MEASUREMENTS - PART 6: PARTS AND SUPPORT EQUIPMENT COMMONALITY AND STANDARDIZATION REQUIREMENTS (PART 6 OF 6 PARTS) |
MIL-PRF-85045-30 Base Document:2009 | CABLE, FIBER OPTIC, RADIATION HARDENED, CABLE CONFIGURATION TYPE 1 (BUFFERED FIBER), APPLICATION E (GROUND TACTICAL), CABLE CLASS SM, (METRIC) |
MIL-STD-2042-6 Revision C:2016 | FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (TESTS) (PART 6 OF 7 PARTS) |
MIL-DTL-24728-10 Base Document:2010 | INTERCONNECTION BOX, CABLE ROUTING, FIBER OPTIC, SPRAYTIGHT, 712 X 1017 MM |
MIL-PRF-32484 Base Document:2013 | PROTECTIVE RELAYS AND ATTACHMENTS, MEDIUM VOLTAGE VACUUM CIRCUIT BREAKER APPLICATIONS |
MIL-DTL-32483 Base Document:2013 | Switchgear, Power, Hard-Mounted, Medium Voltage, Naval Shipboard |
MIL-DTL-917 Revision F:2014 | ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR |
MIL-DTL-24728-9 Base Document:2010 | INTERCONNECTION BOX, CABLE ROUTING, FIBER OPTIC, SPRAYTIGHT, 712 X 1372 MM |
MIL STD 11991 : A | GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES |
MIL-C-83522-1 Revision F:2006 | CONNECTOR, PLUG, FIBER OPTIC, SINGLE TERMINUS, THREADED, (STEP-DOWN NOSE INTERFACE), LENSLESS, EPOXY, FOR 50/125 MICROMETER, 62.5/125 MICROMETER, AND 100/140 MICROMETER |
MIL-PRF-85045-8 Revision B:2008 | CABLE, FIBER OPTIC, RADIATION HARDENED, CABLE CONFIGURATION TYPE 1 (BUFFERED FIBER), APPLICATION E (GROUND TACTICAL), CABLE CLASS MM, (METRIC) |
MIL-PRF-85045-28 Revision A:2014 | Cable, Fiber Optic, Nineteen Tube, Blown Optical Fiber, Standard and Enhanced Performance, Cable Configuration Type 5 (Tube), Application B (Shipboard), Cable Class SM and MM, (Metric) |
MIL-STD-2042-2 Revision C:2016 | FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (EQUIPMENT) (PART 2 OF 7 PARTS) |
MIL-DTL-83526-21 Revision C:2014 | Connector, Fiber Optic, Circular Hermaphroditic, Bulkhead, Low Profile without Strain Relief, Jam-Nut Mount, 2 and 4 Positions, Expanded Beam |
MIL-DTL-83522-16 Revision C:2013 | Connector, Fiber Optic, Single Terminus, Plug, Bayonet Coupling (ST Style), 2.5 Millimeters Diameter Ferrule, Epoxy |
MIL-STD-1678-5 Revision B:2016 | FIBER OPTIC CABLING SYSTEMS REQUIREMENTS AND MEASUREMENTS - PART 5: DESIGN PHASE, SUPPLEMENTAL AND LEGACY MEASUREMENTS (PART 5 OF 6 PARTS) |
MIL-DTL-83526-20 Revision C:2014 | Connector, Fiber Optic Plug, Circular Hermaphroditic, In-Line Mount, 2 and 4 Positions, Expanded Beam |
MIL-DTL-83526 Revision D:2014 | CONNECTORS, FIBER OPTIC, CIRCULAR, ENVIRONMENTAL RESISTANT, HERMAPHRODITIC, GENERAL SPECIFICATION FOR |
SAE AS 6479 : 2014 | SPLICER, FUSION, FIBER OPTIC, AEROSPACE |
SAE AS 6021 : 2014 | AS6021 AEROSPACE FIBER OPTIC CABLE ASSEMBLY DRAWING SPECIFICATION |
MIL-STD-1678-4 Revision C:2016 | FIBER OPTIC CABLING SYSTEMS REQUIREMENTS AND MEASUREMENTS - PART 4: TEST SAMPLE CONFIGURATION AND FABRICATION REQUIREMENTS (PART 4 OF 6 PARTS) |
MIL-DTL-49292 Revision B:2006 | Cable Assemblies, Nonpressure Proof, Fiber Optic, Metric, General Specification for |
MIL-PRF-85045-32 Base Document:2013 | CABLE, FIBER OPTIC, SINGLE (ONE) FIBER, CABLE CONFIGURATION TYPE 2 (OFCC), CABLE CLASS SM AND MM, LOW SMOKE ZERO HALOGEN WITH EXTENDED PERFORMANCE CHARACTERISTICS (METRIC) |
IEEE 45.8-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Cable Systems |
IPC HDBK 630 : 0 | GUIDELINES FOR DESIGN, MANUFACTURE, INSPECTION AND TESTING OF ELECTRONIC ENCLOSURES ASSEMBLY |
MIL-PRF-85045-29 Revision B:2014 | Cable, Fiber Optic, Twelve/Eighteen Fiber Bundle, Blown Optical Fiber, Cable Configuration Type 3 (Cable Bundle), Application B (Shipboard), Cable Class SM and MM, (Metric) |
SAE ARP 5061 : 2003 | GUIDELINES FOR TESTING AND SUPPORT OF AEROSPACE, FIBER OPTIC, INTER-CONNECT SYSTEMS |
MIL-STD-2042-7 Base Document:2002 | FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR NAVAL SHIPS |
MIL-PRF-85045-31 Revision A:2015 | CABLE, FIBER OPTIC, SINGLE (ONE) FIBER, CABLE CONFIGURATION TYPE 2 (OFCC), CLASS SM AND MM, TEMPERATURE RANGE AND OTHER PERFORMANCE CHARACTERISTICS (METRIC) |
SAE AIR 6162 : 2017 | FUSION SPLICING FOR OPTICAL FIBERS |
SAE AIR 6282 : 2015 | FIBER OPTIC HARSH ENVIRONMENT TEST METHODS CROSS REFERENCE DOCUMENT |
SAE AIR 6258 : 2015 | FIBER OPTIC SENSORS FOR AEROSPACE APPLICATIONS |
SAE AS 5659/4 : 2017 | PHYSICAL LAYER SPECIFICATION |
SAE AS 5590 : 2013 | CONNECTORS, FIBER OPTIC, ADVANCED, CIRCULAR OR RECTANGULAR, PLUG AND RECEPTACLE, ENVIRONMENT RESISTANT, REMOVABLE TERMINI/CONTACTS, GENERAL SPECIFICATION FOR |
MIL-DTL-24705-4 Revision A:2014 | PENETRATORS, MULTIPLE CABLE, COMPACT RECTANGULAR METAL FRAME AND BLOCKS, ELECTRICAL AND FIBER OPTIC CABLE |
MIL-STD-2042-1 Revision C:2016 | FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (CABLES) (PART 1 OF 7 PARTS) |
MIL-C-83522-2 Revision G:2006 | CONNECTOR, PLUG, FIBER OPTIC, SINGLE TERMINUS, THREADED, (STRAIGHT NOSE INTERFACE), LENSLESS, EPOXY, FOR 50/125 MICROMETER, 62.5/125 MICROMETER, AND 100/140 MICROMETER |
DSCC 09001 : B | CABLE, FIBER OPTIC, MIXED FIBER (MULTIMODE AND SINGLE MODE FIBERS) |
UL 1685:4ED 2015-07 | Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables |
ASTM E 800 : 2014 : REDLINE | Standard Guide for Measurement of Gases Present or Generated During Fires |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
TIA 455-87 : B1993(R2013) | FOTP-87 - FIBER OPTIC CABLE KNOT TEST |
TIA/EIA 455-81 : B2000 | FOTP-81 - COMPOUND FLOW (DRIP) TEST FOR FILLED FIBER OPTIC CABLE |
FED-STD-228 Revision A:2014 | TEST METHODS FOR CABLES AND WIRE, INSULATED |
ASTM D 512 : 2012 | Standard Test Methods for Chloride Ion In Water (Withdrawn 2021) |
TIA 455-33 : B2005(R2013) | OPTICAL FIBER CABLE TENSILE LOADING AND BENDING TEST |
NASA STD 6001 : 2011 | FLAMMABILITY, OFFGASSING, AND COMPATIBILITY REQUIREMENTS AND TEST PROCEDURES |
MIL I 24728 : A | INTERCONNECTION BOX, FIBER OPTIC, METRIC, GENERAL SPECIFICATION FOR |
ASTM D 1141 : 1998 : EDT 1 | Standard Practice for the Preparation of Substitute Ocean Water |
TIA 455-37 : A1993(R2013) | FOTP-37 LOW OR HIGH TEMPERATURE BEND TEST FOR FIBER OPTIC CABLE |
TIA/EIA 455-25 : D2016 | FOTP-25 - IMPACT TESTING OF OPTICAL FIBER CABLES |
IEC 60794-1-2:2017 | Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance |
ASTM E 595 : 2015 : REDLINE | Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment |
TIA 455-84 : B1992(R1998) | JACKET SELF-ADHESION (BLOCKING) TEST FOR FIBER OPTIC CABLE |
TIA 455-13 : A1996(R2012) | VISUAL AND MECHANICAL INSPECTION OF FIBER OPTIC COMPONENTS, DEVICES, AND ASSEMBLIES |
TIA/EIA 455 : C2014 | STANDARD TEST PROCEDURE FOR FIBER OPTIC FIBERS, CABLES, TRANSDUCERS, SENSORS, CONNECTING AND TERMINATING DEVICES, AND OTHER FIBER OPTIC COMPONENTS |
TIA/EIA 455-88 : 2001 | FIBER OPTIC CABLE BEND TEST |
MIL-HDBK-454 Revision B:2007 | GENERAL GUIDELINES FOR ELECTRONIC EQUIPMENT |
DEFSTAN 02-711/3(2012) : 2012 | DETERMINATION OF THE SMOKE INDEX OF THE PRODUCTS OF COMBUSTION FROM SMALL SPECIMENS OF MATERIALS |
MIL-PRF-49291 Revision D:2013 | FIBER, OPTICAL, (METRIC) GENERAL SPECIFICATION FOR |
MIL-STD-2003-4 Revision A:2009 | ELECTRIC PLANT INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (CABLEWAYS) |
TIA 455-104 : B2016 | FOTP-104 - FIBER OPTIC CABLE CYCLIC FLEXING TEST |
TIA 455-39 : B1999(R2013) | FOTP-39 OPTICAL FIBER CABLE WATER WICKING TEST |
MIL-STD-2042 Revision C:2016 | FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES |
ASTM D 1246 : 2016 : REDLINE | Standard Test Method for Bromide Ion in Water |
TIA/EIA 455-41 : A1993(R2013) | COMPRESSIVE LOADING RESISTANCE OF FIBER OPTIC CABLES |
MIL S 901 : D | SHOCK TESTS, HI [HIGH IMPACT] SHIPBOARD MACHINERY, EQUIPMENT AND SYSTEMS, REQUIREMENTS FOR |
MIL-STD-1678-2 Revision A:2013 | FIBER OPTIC CABLING SYSTEMS REQUIREMENTS AND MEASUREMENTS - PART 2: OPTICAL MEASUREMENTS (PART 2 OF 6 PARTS) |
TT-P-645 Revision C:2013 | PAINT, ALKYD TYPE, FORMULA NUMBER 84 |
MIL-STD-1678-3 Revision C:2016 | FIBER OPTIC CABLING SYSTEMS REQUIREMENTS AND MEASUREMENTS - PART 3: PHYSICAL, MECHANICAL, ENVIRONMENTAL AND MATERIAL MEASUREMENTS (PART 3 OF 6 PARTS) |
MIL-S-24235 Revision C:1992 | STUFFING TUBE, METAL AND PACKING ASSEMBLIES FOR ELECTRIC CABLES, GENERAL SPECIFICATION FOR |
TIA 455-91 : 85(R1996) | FOTP-91 - FIBER OPTIC CABLE TWIST-BEND TEST |
ASTM D 1179 : 2016 : REDLINE | Standard Test Methods for Fluoride Ion in Water |
ASTM D 470 : 2013 : REDLINE | Standard Test Methods for Crosslinked Insulations and Jackets for Wire and Cable |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.