NEN EN 14678-1 : 2013
Current
The latest, up-to-date edition.
12-01-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
4.1 Electrical equipment
4.1.1 General
4.1.2 Cabling insulation resistance
4.1.3 Cables used in hazardous area
4.1.4 Dead man push button
4.1.5 Insulation and isolation
4.1.6 Chemical cells in non-hazardous areas
4.2 Design
4.2.1 Design pressure
4.2.2 Design temperature
4.2.3 Materials
4.2.4 Pressure gauges
4.2.5 Trapped liquid
4.2.6 Joints
4.2.7 Seals and gaskets
4.2.8 Sight glass
4.2.9 LPG system
4.3 Explosion protection measures
4.3.1 General
4.3.2 Avoidance or reduction of ignition sources
4.3.3 Construction measures to limit explosive
atmospheres
4.4 Construction
4.4.1 Mechanical strength
4.4.2 Housing
4.4.3 Stability
4.4.4 Ventilation
4.4.5 Delivery hose assembly
4.4.6 Nozzle
4.4.7 Nozzle boot
4.4.8 Control provisions
5 Type tests
5.1 General
5.2 Sight glass tests
5.2.1 Impact test
5.2.2 Pressure test 1
5.2.3 Pressure test 2
5.3 Pressure tests for LPG system
5.3.1 Pressure test 1
5.3.2 Pressure test 2
5.4 Tests for electric cables used in hazardous areas
5.4.1 General
5.5 Stability test
5.5.1 Test procedure
5.5.2 Test interpretation
5.6 Electrical tests
5.6.1 Continuity of the protective bonding circuit
5.6.2 Insulation resistance tests
5.6.3 Voltage test
5.6.4 Functional tests
5.7 Operational test for the break-away coupling (safe
break)
5.7.1 Test procedure
5.7.2 Test interpretation
5.8 Operational test for the shear valve/break point
5.8.1 Test procedure
5.8.2 Test interpretation
6 Production tests
6.1 Electrical tests
6.2 LPG system tests for dispensers
6.2.1 General
6.2.2 Test procedures
6.2.3 Test interpretation
7 Documentation
7.1 General
7.2 Accompanying documents
8 Marking
8.1 Markings for the user
8.2 Minimum markings
Annex A (normative) Classification of hazardous areas in and
adjacent to the dispenser
A.1 Nozzle area - vapour releases only
A.2 Nozzle boot area
Annex B (normative) Classification of vapour barriers
B.1 General
B.2 Vapour barrier - Type 1
B.3 Vapour barrier - Type 2
B.4 Typical vapour barrier arrangements
Annex C (informative) Information on explosion protected
equipment
Annex ZA (informative) Relationship between this European
Standard and the Essential
Requirements of EU Directive 94/9/EC
Bibliography