NF EN 60565 : 2007

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

UNDERWATER ACOUSTICS - HYDROPHONES - CALIBRATION IN THE FREQUENCY RANGE 0,01 HZ TO 1 MHZ
Superseded date

05-10-2021

Published date

12-01-2013

1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Procedures for calibrations
   5.1 Principles
   5.2 Field limitations
   5.3 Schematic survey of procedures
   5.4 Reporting of results
   5.5 Recalibration periods
   5.6 Temperature and pressure considerations for
         calibration
6 Preparation of transducers
   6.1 Wetting
   6.2 Hydrophone support
   6.3 Influence of cable
7 Electrical measurements
   7.1 Signal type
   7.2 Earthing
   7.3 Measurement of hydrophone output voltage
   7.4 Measurement of projector current
   7.5 Measurement of transfer impedance
8 Free-field reciprocity calibration
   8.1 General principle
   8.2 Theory
   8.3 Separation distance
   8.4 Minimum distance from transducers to boundary surface
   8.5 Frequency limitation
   8.6 Measurements and checks
   8.7 Uncertainty
9 Free-field calibration by comparison
   9.1 Principle
   9.2 Comparison with a standard hydrophone
   9.3 Calibration with a calibrated projector
10 Calibration by hydrostatic excitation
   10.1 Principle
   10.2 Determination of equivalent pressure
   10.3 Measurement of the sensitivity of hydrophones
   10.4 Design of vibration system
   10.5 Uncertainty
   10.6 Alternative method for hydrostatic excitation
11 Calibration by piezoelectric compensation
   11.1 Principle
   11.2 Procedure
   11.3 Design of the calibration chamber
   11.4 Practical limitations of the piezoelectric
         compensation method
   11.5 Uncertainty
12 Acoustic coupler reciprocity calibration
   12.1 Principle
   12.2 Procedure
   12.3 Theory
   12.4 Acoustic compliance
   12.5 High-frequency limit
   12.6 Low-frequency limit
   12.7 Measurement
   12.8 Uncertainty
   12.9 Limitations
   12.10 Acoustic-coupler calibration using a reference
         coupler with two reciprocal transducers and an
         auxiliary coupler with the same two transducers
         and a hydrophone to be calibrated
   12.11 Acoustic-coupler calibration using a reference coupler
         with two reciprocal transducers and an auxiliary
         coupler with the same two transducers, a hydrophone
         to be calibrated, and a sound source
   12.12 Acoustic-coupler calibration using a coupler,
         a reciprocal transducer, a projector, a hydrophone
         to be calibrated, and a subsidiary body of known
         compliance
13 Calibration with a pistonphone
   13.1 Principle
   13.2 Procedure
   13.3 Limitations
   13.4 Uncertainty
14 Calibration with a vibrating column
   14.1 Principle
   14.2 Procedure
   14.3 Expression for the pressure
   14.4 Determination of the sensitivity
   14.5 Conditions of measurement
   14.6 Uncertainty
Annex A (informative) Directional response of a hydrophone
Annex B (informative) Electrical loading corrections
Annex C (informative) Pulsed techniques in free-field
                      calibrations
Annex D (informative) Assessment of uncertainty in the
                      calibration of hydrophones
Annex E (informative) Equivalent circuit of the excitation
                      system for calibration with a vibrating
                      column
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications
Bibliography

Specifies methods for calibration of hydrophones or reversible transducers when used as a hydrophone, particularly in the frequency range from 0,01 Hz to 1 MHz. Rules for the presentation of the calibration data are established.

DevelopmentNote
Indice de classement: C97-915 PR NF EN 60565 November 2004. (11/2004)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
IEC 60565:2006 Identical
EN 60565:2007 Identical
NBN EN 60565 : 2007 Identical
I.S. EN 60565:2007 Identical
BS EN 60565:2007 Identical
DIN EN 60565:2007-08 Identical

NF EN 62127-1 : 2008 AMD 1 2013 ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ
NF EN 62127-2 : 2008 AMD 2 2017 ULTRASONICS - HYDROPHONES - PART 2: CALIBRATION FOR ULTRASONIC FIELDS UP TO 40 MHZ

IEC 60050-801:1994 International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics
NFC 01 801 : 1999 ELECTROTECHNICAL VOCABULARY - CHAPTER 801: ACOUSTICS AND ELECTRO ACOUSTICS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.