ELECTRICITY METERING - DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL - PART 31: USE OF LOCAL AREA NETWORKS ON TWISTED PAIR WITH CARRIER SIGNALLING
Superseded date

29-04-2017

Published date

12-01-2013

AVANT-PROPOS
1 Généralités
  1.1 Domaine d'application
  1.2 Références normatives
2 Présentation générale
  2.1 Vocabulaire de base
  2.2 Couches et protocoles
  2.3 Langage de spécification
  2.4 Services de communication pour l'échange de
      données en bus local sans DLMS
  2.5 Services de communication pour l'échange de
      données par bus local avec DLMS
  2.6 Système d'administration
3 Echange de données par bus local sans DLMS
  3.1 Couche Physique
  3.2 Couche Liaison
  3.3 Couche Application
4 Echange de données par bus local avec DLMS
  4.1 Couche Physique
  4.2 Couche Liaison
  4.3 Couche Application
5 Echange des données par bus en local - Spécifications
  matérielles
  5.1 Généralités
  5.2 Caractéristiques générales
  5.3 Spécification du bus
  5.4 Couplage magnétique
  5.5 Spécifications fonctionnelles de l'émetteur de la
      Station Primaire
  5.6 Spécifications fonctionnelles du récepteur de la
      Station Primaire
  5.7 Spécifications fonctionnelles de l'émetteur de la
      Station Secondaire
  5.8 Spécifications fonctionnelles du récepteur de la
      Station Secondaire
Annexe A (normative) Langage de spécification
Annexe B (normative) Types et caractéristiques des
                        temps
Annexe C (normative) Liste des erreurs fatales
Annexe D (normative) Codage du champ de commande des
                        trames
Annexe E (normative) Principe du CRC
Annexe F (normative) Génération de nombres aléatoires
                        pour la réponse des stations
                        oubliées
Annexe G (normative) Génération de nombres aléatoires
                        pour l'authentification
                        (architecture sans DLMS)
Annexe H (normative) Implémentation du service
                        d'administration des systèmes
Annexe I (informative) Précision sur les échanges
Annexe ZA (normative) Références normatives à d'autres
                        publications internationales avec
                        les publications européennes
                        correspondantes

Details two new architectures for local bus data exchange with stations either energized or not. The bus supplies energy for data exchange, for non-energized stations. First architecture completes the base protocol with remote transfer services. The second architecture gives operation of dlms services by using the same physical layer and medium. The compatibility guarantees possible use of Iec 61142 and iec 62056-31 equipment on the same bus.

DevelopmentNote
Indice de classement: C44-056-31PR. Supersedes NF EN 61142. (09/2000) Supersedes NFC 44 107. (09/2005) PR NF EN 62056-31 September 2010. (09/2010)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 62056-31:1999 Identical
I.S. EN 62056-31:2000 Identical
NBN EN 62056-31 : 2000 Identical
SN EN 62056-31 : 2000 Identical
DIN EN 62056-31 : 2000 Identical
UNE-EN 62056-31:2001 Identical
BS EN 62056-31:2000 Identical
EN 62056-31:2000 Identical

NFC 14 100 : 2008 AMD 3 2016 LOW-VOLTAGE MAINS INSTALLATIONS

IEC 61334-4-41:1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 41: Application protocol - Distribution line message specification
ISO/IEC 8482:1993 Information technology Telecommunications and information exchange between systems Twisted pair multipoint interconnections
NF EN 61334 4-41 : 1997 DISTRIBUTION AUTOMATION USING DISTRIBUTION LINE CARRIER SYSTEMS - PART 4: DATA COMMUNICATION PROTOCOLS - SECTION 41: APPLICATION PROTOCOLS - DISTRIBUTION LINE MESSAGE SPECIFICATION

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.