• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NF EN 62153-1-1 : 2004

Current

Current

The latest, up-to-date edition.

METALLIC COMMUNICATION CABLES TEST METHODS - PART 1-1: ELECTRICAL - MEASUREMENT OF THE PULSE/STEP RETURN LOSS IN THE FREQUENCY DOMAIN USING THE INVERSE DISCRETE FOURIER TRANSFORMATION (IDFT)

Published date

12-01-2013

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Measurement principle
5 Performance calculations
6 Procedure
  6.1 Coaxial cables
      6.1.1 Equipment
      6.1.2 Preparation of test specimen
      6.1.3 Calibration
      6.1.4 Attenuation constant
  6.2 Balanced cables
7 Expression of results
8 Requirements
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

Specifies the test which determines the regularity of impedance of r.f. cables by measuring the return loss in the frequency domain using a vector network analyser equipped with a reflection test set (bridge) and transferring the results into the time domain by using the Inverse Discrete Fourier Transformation (IDFT).

DevelopmentNote
Indice de classement: C90-133-1-1. (05/2004)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

Standards Relationship
BS EN 62153-1-1:2004 Identical
EN 62153-1-1:2004 Identical
DIN EN 62153-1-1:2004-09 Identical
IEC 62153-1-1:2003 Identical
I.S. EN 62153-1-1:2004 Identical

NF EN 50117-2-1 : 2005 AMD 2 2016 COAXIAL CABLES - PART 2-1: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
NF EN 50117-4-1 : 2008 AMD 1 2013 COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
NF EN 50117-2-3 : 2005 AMD 2 2016 COAXIAL CABLES - PART 2-3: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
NF EN 50117-2-2 : 2005 AMD 2 2016 COAXIAL CABLES - PART 2-2: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
NF EN 50117-2-4 : 2005 AMD 2 2016 COAXIAL CABLES - PART 2-4: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
NF EN 50117-2-5 : 2005 AMD 2 2016 COAXIAL CABLES - PART 2-5: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.