NFPA 8503 : 1997

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

PULVERIZED FUEL SYSTEMS
Available format(s)

Hardcopy

Superseded date

09-02-2001

Language(s)

English

Published date

01-01-1997

Chapter 1 Introduction
1-1 Scope
1-2 Purpose
1-3 Basic principles
1-4 Definitions
Chapter 2 Design
2-1 Introduction
2-2 System arrangement requirements
2-3 Piping arrangement
2-4 Inerting arrangement
2-5 System arrangements
2-6 Pulverizer system component design requirments
2-7 Safety interlock systems
Chapter 3 Operation
3-1 Introduction
3-2 Operation of all pulverized fuel systems
3-3 Operation of direct-fired systems
3-4 Operation of storage systems
3-5 Abnormal pulverizer system conditions
Chapter 4 Personnel Safety
4-1 Confined spaces
4-2 Raw fuel bunkers
4-3 Maintenance rules
4-4 Electrical tools and lighting
Chapter 5 Special Systems
5-1 Introduction
5-2 Semi-direct-firing system
5-3 Pulverized fuel system for blast furnace injection
5-4 Firing system for rotary kilns
Chapter 6 Referenced Publications
Appendix A Explanatory material
Appendix B Direct-firing circulating system
Appendix C Direct-firing system for firing zinc-fuming
            furnace
Appendix D Maintenance, inspection and training
Appendix E Reference publications
Index

Details requirements for design, installation, operation, maintenance and personnel safety around pulverised fuel systems. Also includes contributing to operating safety and minimizing the probability of pulverized fuel system explosions and the effects of explosions that occur. This standard covers only those fuels having reactivities greater than that of Pennsylvania anthracite with a volatile content of 8 percent on a dry basis.

DevelopmentNote
Formerly NFPA 85F
DocumentType
Standard
Pages
41
PublisherName
National Fire Protection Association
Status
Superseded
SupersededBy
Supersedes

NFPA 8502 : 1999 PREVENTION OF FURNACE EXPLOSIONS/IMPLOSIONS IN MULTIPLE BURNER BOILERS
ASHRAE HDBK REFRIGERATION : 2014 ASHRAE HANDBOOK - REFRIGERATION
UFC 3-430-11 : 2001 UNIFIED FACILITIES CRITERIA - BOILER CONTROL SYSTEMS

View more information

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.