• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

PREN 772-16 : DRAFT 2010

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

METHODS OF TEST FOR MASONRY UNITS - PART 16: DETERMINATION OF DIMENSIONS
Superseded date

01-05-2011

Published date

12-01-2013

Foreword
1 Scope
2 Normative references
3 Principle
4 Symbols
5 Apparatus
6 Preparation of specimens
7 Procedure
8 Calculation and expression of results
9 Test report
Annex A (informative) - Examples of paths chosen for the
        measurement of combined thickness
Annex B (informative) - Significant technical changes between
        this European standard and the previous edition

Defines a method of determining the overall dimensions, thickness and combined thickness of shells and webs, depth of voids and plane parallelism of the bed faces of masonry units.

Committee
TC 125
DocumentType
Draft
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
10/30215383 DC : 0 Identical

EN 1052-4:2000 Methods of test for masonry - Part 4: Determination of shear strength including damp proof course
PREN 772-11 : DRAFT 2010 METHODS OF TEST FOR MASONRY UNITS - PART 11: DETERMINATION OF WATER ABSORPTION OF AGGREGATE CONCRETE, AUTOCLAVED AERATED CONCRETE, MANUFACTURED STONE AND NATURAL STONE MASONRY UNITS DUE TO CAPILLARY ACTION AND THE INITIAL RATE OF WATER ABSORPTION OF CLAY MASONRY UNITS
BS EN 1052-4:2000 Methods of test for masonry Determination of shear strength including damp proof course
UNI EN 1052-4 : 2001 METHODS OF TEST FOR MASONRY - DETERMINATION OF SHEAR STRENGTH INCLUDING DAMP PROOF COURSE
10/30215380 DC : 0 BS EN 772-11 - METHODS OF TEST FOR MASONRY UNITS - PART 11: DETERMINATION OF WATER ABSORPTION OF AGGREGATE CONCRETE, AUTOCLAVED AERATED CONCRETE, MANUFACTURED STONE AND NATURAL STONE MASONRY UNITS DUE TO CAPILLARY ACTION AND THE INITIAL RATE OF WATER ABSORPTION OF CLAY MASONRY UNITS
BS EN 772-3:1998 Methods of test for masonry units Determination of net volume and percentage of voids of clay masonry units by hydrostatic weighing
EN 772-3:1998 Methods of test for masonry units - Part 3: Determination of net volume and percentage of voids of clay masonry units by hydrostatic weighing

EN 771-3:2011+A1:2015 Specification for masonry units - Part 3: Aggregate concrete masonry units (Dense and lightweight aggregates)
EN 771-4:2011+A1:2015 Specification for masonry units - Part 4: Autoclaved aerated concrete masonry units
EN 771-6:2011+A1:2015 Specification for masonry units - Part 6: Natural stone masonry units
EN 771-1:2011+A1:2015 Specification for masonry units - Part 1: Clay masonry units
EN 771-5:2011+A1:2015 Specification for masonry units - Part 5: Manufactured stone masonry units
EN 771-2:2011+A1:2015 Specification for masonry units - Part 2: Calcium silicate masonry units

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.