    TELECOMMUNICATIONS PATHWAYS AND SPACES

    Available format(s): 

    Superseded date:  03-09-2022

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Telecommunications Industry Association

    Add to Watchlist

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Introduction
    1.1 General
    1.2 Purpose
    1.3 Expected usefulness
    1.4 Relation to other organizations
    1.5 Mandatory, advisory terms
    1.6 Metric equivalents of U.S. customary units
    1.7 Life of this standard
    2 Scope
    2.1 General
    2.2 Basic building elements
    2.3 Normative references
    3 Definitions, Abbreviations and Acronyms, Units
    3.1 Definitions
    3.2 Abbreviations and acronyms
    3.3 Units
    4 Horizontal Pathways and Related Spaces
    4.1 General
    4.2 Underfloor pathways
    4.3 Access floor
    4.4 Conduit
    4.5 Cable trays and wireways
    4.6 Ceiling pathway
    4.7 Perimeter pathways
    4.8 Miscellaneous
    5 Intrabuilding Backbone Pathways and Related Spaces
    5.1 General
    5.2 Design guidelines
    6 Work Area
    6.1 General
    6.2 Telecommunications outlet locations
    6.3 Furniture pathways and spaces
    6.4 Control center, attendant, and reception areas
    7 Telecommunications Closet
    7.1 General
    7.2 Design considerations
    8 Equipment Room
    8.1 General
    8.2 Design considerations
    8.3 Main terminal space
    9 Entrance Facilities
    9.1 General
    9.2 Entrance location considerations
    9.3 Service entrance pathway
    9.4 Entrance point
    9.5 Entrance room or space
    10 Miscellaneous Items
    10.1 Firestopping
    10.2 Elevator telecommunications
    10.3 Horizontal pathway separation from EMI sources
    Annexe A (normative) Firestopping
    A.1 Scope
    A.2 Terminology and definitions
    A.3 Firestops
    A.4 Quality control considerations
    A.5 Categories of firestop systems
    A.6 Design consideration checklist
    Annexe B (informative) Additional Section Information
    B.1 General
    B.2 Horizontal pathways
    B.3 Smaller building telecommunications closet
    B.4 Requirements for equipment delivery
    B.5 Grounding and bonding
    Annexe C (normative) Interbuilding Backbone Pathways and Related Spaces
    C.1 General
    C.2 Building site and entrance considerations
    C.3 Interbuilding and entrance pathways
    C.4 General considerations for pathway types
    C.5 Interbuilding pathway design considerations
    C.6 Space design considerations
    Annexe D (informative) References
    Figures
    2.2-1 Intrabuilding elements
    4.2-1 Single-level underfloor duct
    4.2-2 Two-level underfloor duct
    4.2-3 Flushduct underfloor system
    4.2-4 Multichannel raceway
    4.2-5 Header duct closet termination
    4.2-6 Underfloor duct layout
    4.2-7 Steel cellular floor
    4.2-8 Concrete cellular floor
    4.2-9 Trenchduct cellular floor
    4.3-1 Typical Access floor
    4.5-1 Ventilated cable tray
    4.5-2 Lay-in wireway
    4.6-1 Typical utility column
    4.6-2 Typical ceiling distribution system
    4.7-1 Typical perimeter raceway
    4.8-1 Typical transition boxes in columns
    5.2-1 Typical office building layout
    5.2-2 Typical sleeve and slot installations
    6.3-1 Dimensions for furniture telecommunications outlet opening
    7.2-1 Typical floor layout
    7.2-2 Typical telecommunications closet
    9.3-1 Typical Underground Entrance
    9.4-1 Entrance conduit or sleeve termination
    9.4-2 Encased entrance conduit termination
    A.5-1 Mechanical firestops
    B.3-1 Typical shallow closet
    C.1-1 Typical interbuilding underground layout
    C.4-1 Typical Underground Entrance
    C.4-2 Plate wall strap
    C.4-3 Large cable entrance
    C.4-4 Small cable entrance
    C.4-5 Attachment - unfinished buildings
    C.4-6 Typical tunnel section
    C.5-1 Entrance conduit or sleeve termination
    C.5-2 Maximum section length between maintenance holes
    C.6-1 Typical maintenance hole (Type A)
    C.6-2 Typical handhole
    Tables
    4.4-1 Conduit sizing
    4.8-1 Transition box sizes
    5.2-1 Conduit fill for backbone cable
    5.2-2 Pull box sizing
    5.2-3 Splice box sizing
    7.2-1 Telecommunications closet size
    8.2-1 Equipment room floor space
    8.2-2 Contamination limits
    8.3-1 Minimum termination wall length
    8.3-2 Minimum termination floor space
    B.1-1 Conduit dimensions
    B.2-1 Performance criteria for dynamic loading
    B.2-2 Performance criteria for static loading
    C.5-1 Conduit fill for backbone cable

    Abstract - (Show below) - (Hide below)

    Describes requirements for telecommunications pathways and spaces.

    General Product Information - (Show below) - (Hide below)

    Committee TR-42
    Development Note 2015 version includes AMD 1. (11/2016)
    Document Type Standard
    Publisher Telecommunications Industry Association
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    EEE 602 : 2007 ELECTRIC SYSTEMS IN HEALTH CARE FACILITIES
    ASTM E 1663 : 2003 Standard Classification for Serviceability of an Office Facility for Typical Office Information Technology
    CSA T529 : 0 DESIGN GUIDELINES FOR TELECOMMUNICATIONS WIRING SYSTEMS IN COMMERCIAL BUILDINGS
    BS ISO 16425 : 2013 SHIPS AND MARINE TECHNOLOGY - GUIDELINES FOR INSTALLATION OF SHIP COMMUNICATION NETWORK FOR SHIPBOARD EQUIPMENT AND SYSTEMS
    CSA T568.1-2 : 2005 COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 1: GENERAL REQUIREMENTS - ADDENDUM 2 - GROUNDING AND BONDING SPECIFICATIONS FOR SCREENED BALANCED TWISTED-PAIR HORIZONTAL CABLING
    TIA/EIA 568 SET : C2009 COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD SET
    UFC 3-580-01 : Change 1 UNIFIED FACILITIES CRITERIA - TELECOMMUNICATIONS INTERIOR INFRASTRUCTURE PLANNING AND DESIGN
    CSA T568.1-2 : 2005 : R2010 COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 1: GENERAL REQUIREMENTS - ADDENDUM 2 - GROUNDING AND BONDING SPECIFICATIONS FOR SCREENED BALANCED TWISTED-PAIR HORIZONTAL CABLING
    CSA T568.3 : 2005 : R2010 OPTICAL FIBER CABLING COMPONENTS STANDARD
    CSA T568.3 : 2005 OPTICAL FIBER CABLING COMPONENTS STANDARD
    CSA T568.1 : 2005 COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 1: GENERAL REQUIREMENTS
    CSA T568.1 : 2005 : R2010 COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 1: GENERAL REQUIREMENTS
    SCTE 203 : 2014 PRODUCT ENVIRONMENTAL REQUIREMENTS FOR CABLE TELECOMMUNICATIONS FACILITIES - TEST METHODS
    EIA/TIA 568 : A95 ADDENDA 5 00 COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD
    IEEE 525 : 2007 DESIGN AND INSTALLATION OF CABLE SYSTEMS IN SUBSTATIONS
    ISO 16425:2013 Ships and marine technology Guidelines for the installation of ship communication networks for shipboard equipment and systems
    ASTM E 1663 : 2003 : R2010 Standard Classification for Serviceability of an Office Facility for Typical Office Information Technology
    NEMA PRP 5 : 2015 INSTALLATION GUIDELINES FOR SURFACE NONMETALLIC RACEWAY
    NFPA 99 : 2018 HEALTH CARE FACILITIES CODE
    IEEE 1682 : 2011 TRIAL-USE STANDARD FOR QUALIFYING FIBER OPTIC CABLES, CONNECTIONS, AND OPTICAL FIBER SPLICES FOR USE IN SAFETY SYSTEMS IN NUCLEAR POWER GENERATING STATIONS
    CSA Z8000 : 2011 : R2016 CANADIAN HEALTH CARE FACILITIES
    CSA Z8000 : 2011 CANADIAN HEALTH CARE FACILITIES
    CSA Z8000 : 2011 : INC : UPD 1 : 2013 CANADIAN HEALTH CARE FACILITIES
    SCTE 186 : 2016 PRODUCT ENVIRONMENTAL REQUIREMENTS FOR CABLE TELECOMMUNICATIONS
    CSA T528 : 93(R1997) DESIGN GUIDELINES FOR ADMINISTRATION OF TELECOMMUNICATIONS INFRASTRUCTURE IN COMMERCIAL BUILDINGS
    CSA T527 : 0 GROUNDING AND BONDING FOR TELECOMMUNICATIONS IN COMMERCIAL BUILDINGS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective