1 Scope
2 Normative references
3 Definitions, symbols and abbreviations
   3.1 Terms and definitions
   3.2 Symbols and abbreviations
4 Classification
   4.1 Exposure classes related to environmental actions
   4.2 Fresh concrete
        4.2.1 Consistence classes
        4.2.2 Classes related to maximum aggregate size
   4.3 Hardened concrete
        4.3.1 Compressive strength classes
        4.3.2 Density classes for light-weight concrete
5 Requirements for concrete and methods of verification
   5.1 Basic requirements for constituent materials
        5.1.1 General
        5.1.2 Cement
        5.1.3 Aggregates
        5.1.4 Mixing water
        5.1.5 Admixtures
        5.1.6 Additions (including mineral fillers and pigments)
   5.2 Basic requirements for composition of concrete
        5.2.1 General
        5.2.2 Selection of cement
        5.2.3 Use of aggregates
        5.2.4 Use of recycled water
        5.2.5 Use of additions
        5.2.6 Use of admixtures
        5.2.7 Chloride content
        5.2.8 Concrete temperature
   5.3 Requirements related to exposure classes
        5.3.1 General
        5.3.2 Limiting values for concrete composition
        5.3.3 Performance-related design methods
   5.4 Requirements for fresh concrete
        5.4.1 Consistence
        5.4.2 Cement content and water/cement ratio
        5.4.3 Air content
        5.4.4 Maximum aggregate size
   5.5 Requirements for hardened concrete
        5.5.1 Strength
        5.5.2 Density
        5.5.3 Resistance to water penetration
        5.5.4 Reaction to fire
6 Specification of concrete
   6.1 General
   6.2 Specification for designed concrete
        6.2.1 General
        6.2.2 Basic requirements
        6.2.3 Additional requirements
   6.3 Specification for prescribed concrete
        6.3.1 General
        6.3.2 Basic requirements
        6.3.3 Additional requirements
   6.4 Specification of standardized prescribed concrete
7 Delivery of fresh concrete
   7.1 Information from the user of the concrete to the producer
   7.2 Information from the producer of the concrete to the user
   7.3 Delivery ticket for ready-mixed concrete
   7.4 Delivery information for site-mixed concrete
   7.5 Consistence at delivery
8 Conformity control and conformity criteria
   8.1 General
   8.2 Conformity control for designed concrete
        8.2.1 Conformity control for compressive strength
        8.2.2 Conformity control for tensile splitting strength
        8.2.3 Conformity control for properties other than strength
   8.3 Conformity control of prescribed concrete including
        standardized prescribed concrete
   8.4 Actions in the case of non-conformity of the product
9 Production control
   9.1 General
   9.2 Production control systems
   9.3 Recorded data and other documents
   9.4 Testing
   9.5 Concrete composition and initial testing
   9.6 Personnel, equipment and installation
        9.6.1 Personnel
        9.6.2 Equipment and installation
   9.7 Batching of constituent materials
   9.8 Mixing of concrete
   9.9 Production control procedures
10 Evaluation of conformity
   10.1 General
   10.2 Assessment, surveillance and certification of production
        control
11 Designation for designed concrete
Annex A (normative) Initial test
Annex B (normative) Identity testing for compressive strength
Annex C (normative) Provisions for assessment, surveillance and
        certification of production control
Annex D (informative) Bibliography
Annex E (informative) Guidance on the application of the
        equivalent performance concept of concrete properties
Annex F (informative) Recommendations for limiting values of
        concrete compositions
Annex G Text deleted
Annex H (informative) Additional provisions for high strength
        concrete
Annex J (informative) Performance-related design methods with
        respect to durability
Annex K (informative) Concrete families
Figures
Tables

Pertains to concrete for structures cast in situ, precast structures, and structural precast products for buildings and civil engineering structures.

DevelopmentNote
Supersedes UNI ENV 206 and UNI 9858. (11/2001)
DocumentType
Standard
PublisherName
Ente Nazionale Italiano di Unificazione (UNI)
Status
Superseded
SupersededBy
Supersedes

UNI 11211-4 : 2012 ROCKFALL PROTECTIVE MEASURES - PART 4: DEFINITIVE AND EXECUTIVE DESIGN
UNI 11152 : 2005 WATER SUSPENSIONS OF HYDRAULIC BINDERS FOR GROUTING - CHARACTERISTICS AND TEST METHODS
UNI 11504 : 2013 ALKALI-AGGREGATE REACTION IN CONCRETE - DETERMINATION OF THE POTENTIAL ALKALY-REACTIVITY OF THE AGGREGATE FOR CONCRETE - TEST OF ACCELERATED EXPANSION OF MORTAR BARS
UNI 11307 : 2008 TESTING FOR HARDENED CONCRETE - SHRINKAGE DETERMINATION
UNI/TS 11417-2 : 2014 DURABILITY OF CONCRETE WORKS AND PRECAST CONCRETE ELEMENTS - PART 2: CRITERIA FOR THE AVOIDANCE OF ALKALI-SILICA REACTION
UNI 11521 : 2014 STONE WALL AND CEILING COVERINGS - INSTRUCTION FOR THE DESIGN, INSTALLATION AND MAINTENANCE
UNI 11385 : 2010 CONCRETE MANHOLES AND INSPECTION CHAMBERS, UNREINFORCED, STEEL FIBRE AND REINFORCED - COMPLEMENTARY REQUIREMENTS AND TEST METHODS TO UNI EN 1917
UNI 11417-1 : 2012 DURABILITY OF CONCRETE WORKS AND PRECAST CONCRETE ELEMENTS - PART 1: INSTRUCTIONS TO ACHIEVE THE RESISTANCE TO AGGRESSIVE ACTIONS
UNI 11417-2 : 2012 DURABILITY OF CONCRETE WORKS AND PRECAST CONCRETE ELEMENTS - PART 2: CRITERIA FOR THE AVOIDANCE OF ALKALI-SILICA REACTION
UNI 11530 : 2014 ALKALI-AGGREGATE REACTION IN CONCRETE - DETECTION OF POTENTIAL ALKALI-REACTIVITY OF AGGREGATES FOR CONCRETE - DETAILED PETROGRAPHIC EXAMINATION TO DETECT POTENTIALLY ALKALI-REACTIVE CONSTITUENTS OF AGGREGATES
UNI 11493 : 2013 FLOOR AND WALL CERAMIC TILINGS - INSTRUCTION FOR THE DESIGN, INSTALLATION AND MAINTENANCE OF CERAMIC TILINGS
UNI/TR 11370 : 2010 ROAD SAFETY DEVICES FOR MOTORCYCLIST - PERFORMANCE CLASSES, TEST METHODS AND ACCEPTANCE CRITERIA
UNI 10929 : 2011 SELF LOADING MOBILE MIXERS - DEFINITIONS, TERMINOLOGY AND CLASSIFICATION
UNI 11364 : 2010 CONCRETE PIPES AND FITTINGS, UNREINFORCED, STEEL FIBRE AND REINFORCED - COMPLEMENTARY REQUIREMENTS AND TEST METHODS TO UNI EN 1916
UNI 11279-2 : 2008 ENGINEERED REPOSITORY FOR CATEGORY 2 RADIOACTIVE WASTE PACKAGES - PART 2: BASIC QUALIFICATION CRITERIA FOR ENGINEERED BARRIERS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.